LTC5507 - 100kHz to 1GHz RF Power Detector.
... output voltage range of 0.25V to VCC – 0.1V. RF Detector The internal RF Schottky diode peak detector and level shift amplifier converts the RF input signal to a low frequency signal. The frequency range of the RF pin is typically up to 1000MHz. The detector demonstrates excellent operation over a w ...
... output voltage range of 0.25V to VCC – 0.1V. RF Detector The internal RF Schottky diode peak detector and level shift amplifier converts the RF input signal to a low frequency signal. The frequency range of the RF pin is typically up to 1000MHz. The detector demonstrates excellent operation over a w ...
MT-087 TUTORIAL Voltage References
... ±5 mV tolerance on a 5 V reference corresponds to ±0.1% absolute accuracy which is only 10bit accuracy. For a 12-bit system, choosing a reference that has a ±1 mV tolerance may be far more cost effective than performing manual calibration, while both high initial accuracy and calibration will be nec ...
... ±5 mV tolerance on a 5 V reference corresponds to ±0.1% absolute accuracy which is only 10bit accuracy. For a 12-bit system, choosing a reference that has a ±1 mV tolerance may be far more cost effective than performing manual calibration, while both high initial accuracy and calibration will be nec ...
DS1815 3.3V EconoReset with Push-Pull Output FEATURES PIN ASSIGNMENT
... (VCCTP (MAX) to VCCTP (MIN)) ...
... (VCCTP (MAX) to VCCTP (MIN)) ...
Parasitic Inductance Effect on Switching Losses for a High
... The steady decrease in IC system voltages along with the sharp rise in power requirements result in significant current being delivered from the power supply [1]. This trend coupled with the increase in switching speeds of power semiconductor devices, due to the technology transfer from bipolar to M ...
... The steady decrease in IC system voltages along with the sharp rise in power requirements result in significant current being delivered from the power supply [1]. This trend coupled with the increase in switching speeds of power semiconductor devices, due to the technology transfer from bipolar to M ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
... and improve performance. Here the body bias adjustment is done sparingly as needed based on the chip’s process condition, and is not a continuous variable like the supply voltage. However the point of minimum power depends on the ratio of dynamic to leakage power, with the former modulated by the ac ...
... and improve performance. Here the body bias adjustment is done sparingly as needed based on the chip’s process condition, and is not a continuous variable like the supply voltage. However the point of minimum power depends on the ratio of dynamic to leakage power, with the former modulated by the ac ...
Si4455 LOW-POWER PA MATCHING
... This application note provides a description of the matching techniques applied to the low-power Si4455 RFIC family. The typical power regime of the Si4455 is primarily devoted to +10 dBm applications, but it is also able to achieve 12 to 13 dB if required. The matching network has a number of goals ...
... This application note provides a description of the matching techniques applied to the low-power Si4455 RFIC family. The typical power regime of the Si4455 is primarily devoted to +10 dBm applications, but it is also able to achieve 12 to 13 dB if required. The matching network has a number of goals ...
MAX2205–MAX2208 RF Power Detectors in UCSP General Description Features
... detector goes to an op amp in an analog GSM powercontrol scheme, or to an ADC in other systems such as TDMA or discrete-time GSM power control. The MAX2205 has high-input impedance for use with high-value resistive tapping from a CDMA power amplifier. This coupling method is the lowest cost and lowe ...
... detector goes to an op amp in an analog GSM powercontrol scheme, or to an ADC in other systems such as TDMA or discrete-time GSM power control. The MAX2205 has high-input impedance for use with high-value resistive tapping from a CDMA power amplifier. This coupling method is the lowest cost and lowe ...
Analog Devices Welcomes Hittite Microwave Corporation www.analog.com www.hittite.com
... ceramic package operating from DC - 8 GHz. It features an on-chip reference attenuator for use with an external op-amp to provide simple single voltage attenuation control, 0 to -3V. The device is ideal in designs where an analog DC control signal must control RF signal levels over a 30 dB amplitude ...
... ceramic package operating from DC - 8 GHz. It features an on-chip reference attenuator for use with an external op-amp to provide simple single voltage attenuation control, 0 to -3V. The device is ideal in designs where an analog DC control signal must control RF signal levels over a 30 dB amplitude ...
08310024, 08210001, 08110046
... are still used in some cases. The passive approach has the advantage of simplicity, but is comparatively large and heavy, and cannot approach the performance of an active PFC scheme. These circuits are based on the bridge rectifier configuration. In this filter system, the line curren ...
... are still used in some cases. The passive approach has the advantage of simplicity, but is comparatively large and heavy, and cannot approach the performance of an active PFC scheme. These circuits are based on the bridge rectifier configuration. In this filter system, the line curren ...
Aalborg Universitet Tertiary Control for Optimal Unbalance Compensation in Islanded Microgrids
... active filters are used to inject current so as to balance the current and to compensate unbalances [3]. In case of islanded microgrids, DG units can be employed as active filters and compensators so as to make full use of them. In addition, the compensation efforts can be shared among DGs so as to ...
... active filters are used to inject current so as to balance the current and to compensate unbalances [3]. In case of islanded microgrids, DG units can be employed as active filters and compensators so as to make full use of them. In addition, the compensation efforts can be shared among DGs so as to ...
Power Supply Measurement and Analysis
... the oscilloscope will accept voltages up to 1000 V; thus the 700 V signal can be acquired without overdriving the oscilloscope. The problem with using this setting is that the minimum signal amplitude it can resolve is 1000/256, or about 4 V. With the power application software offered with modern o ...
... the oscilloscope will accept voltages up to 1000 V; thus the 700 V signal can be acquired without overdriving the oscilloscope. The problem with using this setting is that the minimum signal amplitude it can resolve is 1000/256, or about 4 V. With the power application software offered with modern o ...
Chapter 6 Notes
... • A feed line delivers all the power to the antenna when the antenna’s feed point impedance and the feed line’s characteristic impedance are the same. • A reflection occurs when the impedances don’t match. Forward power is power traveling toward the antenna and reflected power is power reflected bac ...
... • A feed line delivers all the power to the antenna when the antenna’s feed point impedance and the feed line’s characteristic impedance are the same. • A reflection occurs when the impedances don’t match. Forward power is power traveling toward the antenna and reflected power is power reflected bac ...
DYNAMIC MEASUREMENT UNCERTAINTY OF HV VOLTAGE DIVIDERS
... To evaluate these convolutions, digital filtering may be used as in [4]. Another alternative which will be pursued here is to use a dynamic simulator (section 3.1). How the covariance matrix u Ρ2 can be determined is not addressed here as it is assumed known. Within the framework of dynamic metrolog ...
... To evaluate these convolutions, digital filtering may be used as in [4]. Another alternative which will be pursued here is to use a dynamic simulator (section 3.1). How the covariance matrix u Ρ2 can be determined is not addressed here as it is assumed known. Within the framework of dynamic metrolog ...
Spec Sheet
... Emerson Network Power Surge Protection and the IEEE Standard 1100-1999 (Emerald Book) recommend a properly rated surge protection device should be applied on ALL electrical conductors entering your facility including: power, voice, and data. Without proper protection – data disruption, hardware stre ...
... Emerson Network Power Surge Protection and the IEEE Standard 1100-1999 (Emerald Book) recommend a properly rated surge protection device should be applied on ALL electrical conductors entering your facility including: power, voice, and data. Without proper protection – data disruption, hardware stre ...
Power Electronic Modelling and Emulation of an Electrostatic
... supply. The first system is the “hardware in the loop test system” for testing control unit of the converter. Here the control unit operation can be tested by using different precipitator types and scenarios. The IGBT pulses of the control unit are acquired and the precipitator current and voltage a ...
... supply. The first system is the “hardware in the loop test system” for testing control unit of the converter. Here the control unit operation can be tested by using different precipitator types and scenarios. The IGBT pulses of the control unit are acquired and the precipitator current and voltage a ...