• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Mesh Analysis - No-IP
Mesh Analysis - No-IP

... Also, there is a big difference between branch currents and loop currents. They are equal only when the loop current is the only current involved. For example in loop 2, the currents i2 are the same through the 24 ohm resistor, but they are different at the 4 and 10 ohm resistors in the same loop be ...
6 pulse vs. 12 and 18 pulse harmonics effect reduction White paper
6 pulse vs. 12 and 18 pulse harmonics effect reduction White paper

... harmonics emissions with standards iec/en 61000-3-2 (for equipment up to 16a) and iec/en 61000-3-12 (for equipment consuming more than 16a). Unlike the ieee standard, the iec/en standards regulate the current harmonics that devices are allowed to produce, and are independent of where and how devices ...
Kinetis K22: 120 MHz Cortex-M4F up to 1MB Flash (80 pin)
Kinetis K22: 120 MHz Cortex-M4F up to 1MB Flash (80 pin)

... USB0_DM input voltage ...
BD00HC5MEFJ-M
BD00HC5MEFJ-M

... supply lines. An external direction diode can be added. (3). Power supply lines Design PCB layout pattern to provide low impedance GND and supply lines. To obtain a low noise ground and supply line, separate the ground section and supply lines of the digital and analog blocks. Furthermore, for all p ...
Printing from undefined
Printing from undefined

... 1. Trouble code will set if ECU detects wheel speed sensor has no input signal. Trouble code will also set if wheel sensor voltage output is low while driving vehicle. 2. Inspect wheel sensor wiring harness for open or poor connection. Repair or replace if necessary. If no open circuit or poor conne ...
Investigation on Surface Degradation of Modified Plane Tracking Method
Investigation on Surface Degradation of Modified Plane Tracking Method

... over the dry band, the insulator will function in its high electrical stress region and hence show a slightly conducting behaviour, reducing the resistance of the dry band and consequently reducing the voltage over the dry band. The resulting discharges will be smaller in magnitude and have less dam ...
noise
noise

... Pn = noise power in watts en = noise voltage in volts rms k = 1.38 x 10-23 J/°K T = temperature in °K f = bandwidth of circuit/system in Hz Pink noise - also known as 1/f noise Amplitude is 1/f Of little consequence except at low frequencies Should be infinite @ an infinite period - "big bang" Shot ...
ARC FAULT CIRCUIT INTERRUPTER
ARC FAULT CIRCUIT INTERRUPTER

... insufficient energy to open the overcurrent device. This can cause arcing that can propel particles of molten metal onto nearby combustibles. ...
Simulating PLL reference spurs
Simulating PLL reference spurs

... Spurious levels on the output of a phaselocked loop (PLL) that generates a carrier signal are an important specification in many RF systems. Spurs may come from a variety of sources, but one of the most common is the PLL’s reference clock. This spur is often referred to as the reference spur, or refe ...
ML Maximum Power Point Tracking (MPPT) Series Solar
ML Maximum Power Point Tracking (MPPT) Series Solar

... highest voltage and current values (VI) in real time, enabling the system to charge the battery in maximum power. It's designed to be used in off-grid solar photovoltaic systems to coordinate operation of the solar panel, battery and load, functioning as the core control unit in off-grid photovoltai ...
30 Measuring High Power Laser Diode Junction
30 Measuring High Power Laser Diode Junction

Design And Application Guide For High Speed MOSFET Gate Drive Circuits
Design And Application Guide For High Speed MOSFET Gate Drive Circuits

X Switching Overvoltage Mitigation Measures
X Switching Overvoltage Mitigation Measures

... is to reduce the coupling contribution in any one phase from the other two phases. This measure is inexpensive, easily implemented and reliable. X.5 Line Surge Arresters As an alterative to the use of closing resistors, metal oxide surge arresters were applied on line terminals starting in the late ...
Electricity - Olds High School
Electricity - Olds High School

1. Introduction
1. Introduction

... METRON warrants that the QA-45 Defibrillator/Transcutaneous Pacemaker Analyzer will substantially conform to published specifications and to the documentation, provided that it is used for the purpose for which it was designed. METRON will, for a period of twelve (12) months from date of purchase, r ...
KxxD-FA(D) - User Manual
KxxD-FA(D) - User Manual

... KxxD-FA(D) is a line of load cells (KIMD, KOSD and KEND) with a high degree of protection. They incorporate resistive strain gauges, measuring the shear force or tension. They are equipped with one or two amplifiers each using 2-wire 4 - 20 mA current loop output with low NAMUR error signalling. The ...
MHT1000HR5 2450 MHz, 140 W CW, 28 V Industrial Heating
MHT1000HR5 2450 MHz, 140 W CW, 28 V Industrial Heating

Raygun Rocklite Manual
Raygun Rocklite Manual

... Connecting A Bunch of ROCKLITE™ RAYGUN Fixtures You will need a serial data link to run light shows using a DMX-512 controller or to run shows on two or more fixtures set to sync in master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determ ...
Dialog Specification ()
Dialog Specification ()

... Provide a complete low voltage lighting control system for the building as shown on the plans and specified herein. Lighting control system shall utilize networking technology connecting relay panels, switches and sensors based upon a 2-wire data line providing both power and data to all field devic ...
TURCK IM Series Interface Modules Application Guide
TURCK IM Series Interface Modules Application Guide

... problems associated with the installation of equipment that is used in potentially explosive atmospheres. TURCK's IM series utilizes the intrinsically safe concept that is universally accepted, easy to apply and the safest way to install electronic measuring, monitoring and control equipment in pote ...
ADS1212, ADS1213: 22-Bit Analog-to
ADS1212, ADS1213: 22-Bit Analog-to

Ensuring Power integrity
Ensuring Power integrity

... Observe the effect of the internal SSFM on the spectrum of the commonmode noise which propagates along the speaker cable. Use a narrow ...
Document
Document

... , (2-16) and (2-19) imply that for ...
FDC10 10 Series of Power Moudules : DC/DC Converter
FDC10 10 Series of Power Moudules : DC/DC Converter

... The power module operates in a variety of thermal environments; however, sufficient cooling should be provided to ensure reliable operation of the unit. Heat is removed by conduction, convention, and radiation to the surrounding environment. Proper cooling can be verified by measuring the point as s ...
How to get the best ADC accuracy in STM32 microcontrollers
How to get the best ADC accuracy in STM32 microcontrollers

... device). A self-calibration feature is provided to enhance ADC accuracy versus environmental condition changes. In applications involving analog-to-digital conversion, ADC accuracy has an impact on the overall system quality and efficiency. To improve this accuracy, the errors associated with the AD ...
< 1 ... 573 574 575 576 577 578 579 580 581 ... 2982 >

Opto-isolator



In electronics, an opto-isolator, also called an optocoupler, photocoupler, or optical isolator, is a component that transfers electrical signals between two isolated circuits by using light. Opto-isolators prevent high voltages from affecting the system receiving the signal. Commercially available opto-isolators withstand input-to-output voltages up to 10 kV and voltage transients with speeds up to 10 kV/μs.A common type of opto-isolator consists of an LED and a phototransistor in the same opaque package. Other types of source-sensor combinations include LED-photodiode, LED-LASCR, and lamp-photoresistor pairs. Usually opto-isolators transfer digital (on-off) signals, but some techniques allow them to be used with analog signals.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report