• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AN2764, Improving the Transient Immunity Performance of
AN2764, Improving the Transient Immunity Performance of

... edges and are considered to be the most vulnerable inputs to the system. Appropriate PCB layout is the preferred method to eliminate this risk. As shown in Figure 3, transients can travel from the point of entry and affect circuits via several paths. Signal path #1 results from the I/O pin input cir ...
Design and Implementation of the Universal Interface Controller
Design and Implementation of the Universal Interface Controller

university of north carolina at charlotte
university of north carolina at charlotte

... Note that the galvanometer has three terminals. The black terminal is common. G0 is the low impedance input (60Ω≤G0≤105Ω). G1 is the high impedance input (1.5KΩ≤G1≤2.0KΩ). Always begin by making connections to the “G1” and “-“ terminals to prevent burning out the galvanometer. Connection to the “G0 ...
RGDAT This document has the objective to specify the functions and
RGDAT This document has the objective to specify the functions and

... The characteristics of the reference networks are: - Rated voltage: from 6kV to 25kV ±10% - Maximum current of three-phase short circuit: 20kA - Maximum value of time constant τ of the phase unidirectional component decay: 20ms - Maximum single phase ground fault current (insulated neutral earth): 5 ...
No Slide Title
No Slide Title

... the semiconductor process. On two levels make a large square sheet of metal. The oxide between the layers acts very well as a dielectric. There are refinements to this and fringing capacitance is a problem but basically capacitance is proportional to area. Using more than two levels and alternating ...
On Power Quality of Variable-Speed Constant
On Power Quality of Variable-Speed Constant

... drive generator (IDG) [3], [4]. However, continuing developments in power electronics and microprocessor technology have led to the dc-link variable-speed constant-frequency (VSCF) generating system [5], [6], becoming a viable alternative to the CSD and IDG systems. The VSCF electrical system is mor ...
Product Range 2014 Portable Reference Meters
Product Range 2014 Portable Reference Meters

... Reference meters with accuracy classes 0.2 to 0.02 are commonly used for testing of meter installations and for observing error limits of electricity meters on-site. The primary standard with accuracy class 0.01 is used for very accurate testing of meters and reference meters. Test systems are refer ...
High luminance hybrid light guide plate for
High luminance hybrid light guide plate for

... 10 October 2011 / Vol. 19, No. 21 / OPTICS EXPRESS 20079 ...
AN-366 Designer`s Encyclopedia of One
AN-366 Designer`s Encyclopedia of One

... Operating one-shots with values of the REXT outside recommended limits is at the risk of the user. For some devices it will lead to complete functional failure, while for other devices it may result in either pulse widths different from those values predicted by design charts or equations, or with m ...
S-Series DeltaV Controller Interface for PROVOX I/O
S-Series DeltaV Controller Interface for PROVOX I/O

AD9714/AD9715/AD9716/AD9717 Dual, Low Power 8-/10-/12
AD9714/AD9715/AD9716/AD9717 Dual, Low Power 8-/10-/12

Ultrafast polarization switching in thin-film ferroelectrics
Ultrafast polarization switching in thin-film ferroelectrics

Linköping University Post Print Reduction of Substrate Noise in Sub Clock
Linköping University Post Print Reduction of Substrate Noise in Sub Clock

... Assuming a CMOS driver, the amplitude of the supply current spike depends on the following [4]: 1) aspect ratio of transistors; 2) rise and fall time of input; 3) load capacitance compared with critical capacitance; 4) output voltage; 5) short circuit current. After occurrence of the supply current ...
Aeroflex / KDI-Integrated Products - Aeroflex Microelectronic Solutions
Aeroflex / KDI-Integrated Products - Aeroflex Microelectronic Solutions

... JY04B ASIC from Cobham – FPGA Net List Conversion ...
Fluke Clamp Meters
Fluke Clamp Meters



... 3. Never run Signal or Control cables in the same conduit or raceway with AC power lines, conductors feeding motors, solenoids, SCR controls, and heaters, etc. The cables should be ran in metal conduit that is properly grounded. This is especially useful in applications where cable runs are long and ...
THEORY, CONSTRUCTION, AND OPERATION
THEORY, CONSTRUCTION, AND OPERATION

... the resulting power dissipated as heat is given in watts. In electrical machines this heat represents a loss of energy. It will be shown later that one of the fundamental requirements in designing an electric machine is the efficient removal of these resistive losses, with the purpose of limiting th ...
Power Master AC/DC DIGITAL BATTERY CHARGER DBC Series
Power Master AC/DC DIGITAL BATTERY CHARGER DBC Series

... O/P Current, Charging Current "A": The O/P current will display after pressing "Display Key" for 1 second while displaying "V". Press & hold “Display Key” for 3 seconds while displaying “A” to enable O/P current “zero calibration” (the period approx. 10 seconds) Press “Display Key” for 2 seconds to ...
Average Current Mode Control of Switching Power Supplies
Average Current Mode Control of Switching Power Supplies

... inductor current control functions by comparing the upslope of inductor current (or switch current) to a current program level set by the outer loop-see Fig. 1. The comparator turns the power switch off when the instantaneous current reaches the desired level. The current ramp is usually quite small ...
Glossary of Terms by TDK-Lambda - TDK
Glossary of Terms by TDK-Lambda - TDK

Power
Power

... ■ From reverse-biased p-n junctions ► Between diffusion and substrate or well ...
AD9714 数据手册DataSheet 下载
AD9714 数据手册DataSheet 下载

... Power dissipation @ 3.3 V, 2 mA output 37 mW @ 10 MSPS 86 mW @ 125 MSPS Sleep mode: <3 mW @ 3.3 V Supply voltage: 1.8 V to 3.3 V SFDR to Nyquist 84 dBc @ 1 MHz output 75 dBc @ 10 MHz output AD9717 NSD @ 1 MHz output, 125 MSPS, 2 mA: −151 dBc/Hz Differential current outputs: 1 mA to 4 mA 2 on-chip au ...
Thomas Organ Vox Amplifiers Repair/Replacement PCB
Thomas Organ Vox Amplifiers Repair/Replacement PCB

... introduction through the last models. This same circuit was varied a little within the amp for special features - “Normal” versus “Brilliant” versus “Bass” for instance – and more or less of the circuits were used in different amps. Only in the final year of issue – the V11n3 models – did the basic ...
BL(1)
BL(1)

101101/Thomas Munther
101101/Thomas Munther

... (Parts per Pkg: 2) Look in the figure above ! Place the component somewhere on the workspace. The component is also in the design cache. Check this ! See Figure 31. ...
< 1 ... 502 503 504 505 506 507 508 509 510 ... 2982 >

Opto-isolator



In electronics, an opto-isolator, also called an optocoupler, photocoupler, or optical isolator, is a component that transfers electrical signals between two isolated circuits by using light. Opto-isolators prevent high voltages from affecting the system receiving the signal. Commercially available opto-isolators withstand input-to-output voltages up to 10 kV and voltage transients with speeds up to 10 kV/μs.A common type of opto-isolator consists of an LED and a phototransistor in the same opaque package. Other types of source-sensor combinations include LED-photodiode, LED-LASCR, and lamp-photoresistor pairs. Usually opto-isolators transfer digital (on-off) signals, but some techniques allow them to be used with analog signals.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report