
Document
... based circuits shall be preferred. 4.2.7 The components and assembly of the unit shall conform to RDSO’s reliability specification E-16/1. The use of electrolytic capacitor shall be avoided to the extent possible in design of the inverter. 4.2.8 The detailed specification of all the power switching ...
... based circuits shall be preferred. 4.2.7 The components and assembly of the unit shall conform to RDSO’s reliability specification E-16/1. The use of electrolytic capacitor shall be avoided to the extent possible in design of the inverter. 4.2.8 The detailed specification of all the power switching ...
8.3 Onsite Power System 8.3.1 Alternating Current Power Systems
... grid voltage fluctuations. The normal NPSS alignment has each NAT powering two of the four NPSS trains. In the event of a NAT failure, the affected trains are fasttransferred to the other functioning NAT with minimum voltage decay and frequency difference to limit motor torque during the transfer. T ...
... grid voltage fluctuations. The normal NPSS alignment has each NAT powering two of the four NPSS trains. In the event of a NAT failure, the affected trains are fasttransferred to the other functioning NAT with minimum voltage decay and frequency difference to limit motor torque during the transfer. T ...
Low Ambient Temperature Head Pressure Control
... NOTE: The VFD is phase insensitive in regard to incoming line voltage, which means that the VFD will operate with any phase sequence of the incoming three-phase power. The standard outdoor air temperature limitation of 30RB and 30XA chillers is 32 F (0° C). The low ambient temperature controller ope ...
... NOTE: The VFD is phase insensitive in regard to incoming line voltage, which means that the VFD will operate with any phase sequence of the incoming three-phase power. The standard outdoor air temperature limitation of 30RB and 30XA chillers is 32 F (0° C). The low ambient temperature controller ope ...
chapter 1 introduction
... achieved. The use of electrolysis for ozone production is presently limited to small units used for applications that require high concentrations of ozone, and in-situ diffusion of ozone into ultra pure water. Currently, whilst their capital cost is favourable compared to corona discharge units, the ...
... achieved. The use of electrolysis for ozone production is presently limited to small units used for applications that require high concentrations of ozone, and in-situ diffusion of ozone into ultra pure water. Currently, whilst their capital cost is favourable compared to corona discharge units, the ...
Service Manual for the Kodak Carousel SLIDE PROJECTORS
... The information contained herein is based on the experience and knowledge relating to the subject matter gained by Eastman Kodak Company prior to publication. No patent license is granted by this information. Eastman Kodak Company reserves the right to change this information without notice, and mak ...
... The information contained herein is based on the experience and knowledge relating to the subject matter gained by Eastman Kodak Company prior to publication. No patent license is granted by this information. Eastman Kodak Company reserves the right to change this information without notice, and mak ...
Standards Project - Telecommunications Industry Association
... shows a result that is independent of frequency, while the 900 ohm termination with intervening 2.7 km loop case shows a high frequency roll off. Both are as expected. However, the 900 ohm termination with intervening loop case is shown to be 2.30 dB higher in level at low frequencies than the 600 o ...
... shows a result that is independent of frequency, while the 900 ohm termination with intervening 2.7 km loop case shows a high frequency roll off. Both are as expected. However, the 900 ohm termination with intervening loop case is shown to be 2.30 dB higher in level at low frequencies than the 600 o ...
operation frick® quantum™ hd compressor control
... screen. The current date and time is shown in this title area. The day of the week, Sunday (Sun.) through Saturday (Sat.) is displayed, as well as the month of the year from January (Jan.) to December (Dec.), the day of the month from 1 to 31 and the year from 0001 to 9999 is displayed and the time ...
... screen. The current date and time is shown in this title area. The day of the week, Sunday (Sun.) through Saturday (Sat.) is displayed, as well as the month of the year from January (Jan.) to December (Dec.), the day of the month from 1 to 31 and the year from 0001 to 9999 is displayed and the time ...
XPower Inverter 5000
... Over-temperature shutdown Shuts the inverter down automatically if its internal temperature rises above an acceptable level. Back-EMF (backfeed) protection Shuts the inverter down automatically if a motor that is connected to the AC outlet overloads or if an AC source is connected to the AC outlet. ...
... Over-temperature shutdown Shuts the inverter down automatically if its internal temperature rises above an acceptable level. Back-EMF (backfeed) protection Shuts the inverter down automatically if a motor that is connected to the AC outlet overloads or if an AC source is connected to the AC outlet. ...
Power-Gard Technical Application (Littlefuse)
... Fast-acting fuses (sometimes called “Normal-opening” fuses) have no intentional time-delay. Typical opening times at 500% of the fuse ampere rating range from 0.05 second to approximately 2 seconds. Fast-Acting fuses are suitable for non-inductive loads such as incandescent lighting and general-purp ...
... Fast-acting fuses (sometimes called “Normal-opening” fuses) have no intentional time-delay. Typical opening times at 500% of the fuse ampere rating range from 0.05 second to approximately 2 seconds. Fast-Acting fuses are suitable for non-inductive loads such as incandescent lighting and general-purp ...
WJ200 Series Inverter Instruction Manual
... CAUTION: Remarks for using ground fault interrupter breakers in the main power supply: Adjustable frequency inverter with integrated CE-filters and shielded (screened) motor cables have a higher leakage current toward earth GND. Especially at the moment of switching ON this can cause an inadvertent ...
... CAUTION: Remarks for using ground fault interrupter breakers in the main power supply: Adjustable frequency inverter with integrated CE-filters and shielded (screened) motor cables have a higher leakage current toward earth GND. Especially at the moment of switching ON this can cause an inadvertent ...
Retrofit Kit Manual Model 300/400/500 Swing Door System
... 2. This circuitry was designed to work with any sensor that operates on 24 VAC. This circuitry is limited to 0.500-amp current draw and must not be exceeded. If a sensor requires a different operating voltage, a separate voltage module must be used to supply power to the sensor. J1 is the signal inp ...
... 2. This circuitry was designed to work with any sensor that operates on 24 VAC. This circuitry is limited to 0.500-amp current draw and must not be exceeded. If a sensor requires a different operating voltage, a separate voltage module must be used to supply power to the sensor. J1 is the signal inp ...
Handmade electronic music : the art of hardware
... CMD-X and CMD-V give us the freedom to rearrange words, pictures, video and sound to transform any old thing into our new thing with tremendous ease. But, by and large, this is also an “off-line” world, whose digital tools, as powerful as they might be, are more suitable to preparing texts, photo al ...
... CMD-X and CMD-V give us the freedom to rearrange words, pictures, video and sound to transform any old thing into our new thing with tremendous ease. But, by and large, this is also an “off-line” world, whose digital tools, as powerful as they might be, are more suitable to preparing texts, photo al ...
ORBIS PRODUCT GUIDE
... • FasTest® reduces maintenance time • automatic drift compensation with DirtAlert® warning to easily identify dirty detectors • SensAlert® which indicates that the detector is not operating properly • wide voltage and operating temperature ranges • optical sensor designed for high reliability ...
... • FasTest® reduces maintenance time • automatic drift compensation with DirtAlert® warning to easily identify dirty detectors • SensAlert® which indicates that the detector is not operating properly • wide voltage and operating temperature ranges • optical sensor designed for high reliability ...
T HR SC 01000 SP Common Signals and Control Systems
... common signals and control systems requirements are consolidated in this document. These requirements are based on Australian standards and international standards which provide the primary basis for the equipment requirements. Signals and control systems equipment is typically installed alongside t ...
... common signals and control systems requirements are consolidated in this document. These requirements are based on Australian standards and international standards which provide the primary basis for the equipment requirements. Signals and control systems equipment is typically installed alongside t ...
CD4017 - eeshop home page
... The CD4017BM/CD4017BC is a 5-stage divide-by-10 Johnson counter with 10 decoded outputs and a carry out bit. The CD4022BM/CD4022BC is a 4-stage divide-by-8 Johnson counter with 8 decoded outputs and a carry-out bit. These counters are cleared to their zero count by a logical ‘‘1’’ on their reset lin ...
... The CD4017BM/CD4017BC is a 5-stage divide-by-10 Johnson counter with 10 decoded outputs and a carry out bit. The CD4022BM/CD4022BC is a 4-stage divide-by-8 Johnson counter with 8 decoded outputs and a carry-out bit. These counters are cleared to their zero count by a logical ‘‘1’’ on their reset lin ...
MAX823-825 - Maxim Part Number Search
... supervisory circuits combine reset output, watchdog, and manual reset input functions in 5-pin SOT23 and SC70 packages. They significantly improve system reliability and accuracy compared to separate ICs or discrete components. The MAX823/MAX824/MAX825 are specifically designed to ignore fast transi ...
... supervisory circuits combine reset output, watchdog, and manual reset input functions in 5-pin SOT23 and SC70 packages. They significantly improve system reliability and accuracy compared to separate ICs or discrete components. The MAX823/MAX824/MAX825 are specifically designed to ignore fast transi ...
Williams WPC - Pinball Supernova
... The natural heating and cooling cycle, and vibration, in a pinball machines causes the socketed chips to slowly walk out of their sockets. This loosening can cause mysterious behavior and resets. Firmly pressing each socketed device - including the ASIC - and listening for a small click can solve m ...
... The natural heating and cooling cycle, and vibration, in a pinball machines causes the socketed chips to slowly walk out of their sockets. This loosening can cause mysterious behavior and resets. Firmly pressing each socketed device - including the ASIC - and listening for a small click can solve m ...
QUOTATION Digital oscilloscope
... Display Adjustable Brightness INTERFACE USB Device USB1.1 & 2.0 full speed compatible (Pictbridge Compatibility Printers Supported) USB Host Image (BMP), waveform data (CSV), and setup (SET) POWER SOURCE Line Voltage AC 100V ~ 240V , 48Hz ~ Range 63Hz , Auto selection MISCELLANEOUS MultiLanguage Ava ...
... Display Adjustable Brightness INTERFACE USB Device USB1.1 & 2.0 full speed compatible (Pictbridge Compatibility Printers Supported) USB Host Image (BMP), waveform data (CSV), and setup (SET) POWER SOURCE Line Voltage AC 100V ~ 240V , 48Hz ~ Range 63Hz , Auto selection MISCELLANEOUS MultiLanguage Ava ...
Opto-isolator
In electronics, an opto-isolator, also called an optocoupler, photocoupler, or optical isolator, is a component that transfers electrical signals between two isolated circuits by using light. Opto-isolators prevent high voltages from affecting the system receiving the signal. Commercially available opto-isolators withstand input-to-output voltages up to 10 kV and voltage transients with speeds up to 10 kV/μs.A common type of opto-isolator consists of an LED and a phototransistor in the same opaque package. Other types of source-sensor combinations include LED-photodiode, LED-LASCR, and lamp-photoresistor pairs. Usually opto-isolators transfer digital (on-off) signals, but some techniques allow them to be used with analog signals.