• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0

Digital Multimeter
Digital Multimeter

... meter offers nine different measurement functions plus features that are usually found in much more expensive and larger meters. The digital display is oversized with large digits and unit icons in the display. In spite of its size, this meter is fully safety rated to CAT III 300 V, CAT II 600 V and ...
comdyna
comdyna

... 4. When your ODEs are programmed on the patch panel, and your coefficient values are all entered, and your external input and display instruments are connected, you may run the GP-6 to solve the time-dependent ODEs. With the IC mode control push button still depressed, position the MODE SELECTOR rot ...
16-Bit/18-Bit, 16 FS PCM Audio DACs AD1851/AD1861
16-Bit/18-Bit, 16 FS PCM Audio DACs AD1851/AD1861

... used in consumer audio products. These filters operate at oversampling rates of 23, 43, 83 and 163 sampling frequencies. ...
BAS20 General Purpose High Voltage Diode B A
BAS20 General Purpose High Voltage Diode B A

... (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. ...
FDC6392S 20V Integrated P-Channel PowerTrench MOSFET and Schottky Diode
FDC6392S 20V Integrated P-Channel PowerTrench MOSFET and Schottky Diode

... 1. RθJA is the sum of the junction-to-case and case-to-ambient thermal resistance where the case thermal reference is defined as the solder mounting surface of the drain pins. RθJC is guaranteed by design while RθCA is determined by the user's board design. ...
Kreutter: Circuits 2 Voltage/Current/Resistance Lab Voltage, Current
Kreutter: Circuits 2 Voltage/Current/Resistance Lab Voltage, Current

... Be sure to connect the positive lead from the power supply to the positive terminal of the ammeter. To connect multiple resistors (loads), use alligator clips to fasten them together in series. Your final connection should be to the negative terminal of the power supply. IF YOU SEE OR SMELL SMOKE, ( ...
(1) Output or drain characteristic and
(1) Output or drain characteristic and

... JFET operates as a constant current device sincedrain current (or output current) remains almost constant. It is the normal operating region of the JFET when used as an amplifier. The drain current in the pinch-off region with VGS = 0 is referred to the drain-source saturation current, Idss). It is ...
File - the Analysis of Electrical Engineering ELEC 291
File - the Analysis of Electrical Engineering ELEC 291

Design and development of high voltage high power operational
Design and development of high voltage high power operational

3 Status Driver Output
3 Status Driver Output

... • Capable of switching external loads up to 28Vdc @ 1.0 Amp. (Sinks current to ground) • An open-drain power MOSFET is used as an electronic switch and is referenced to Status Ground (Chassis Ground) • Output state is jumper programmable with one of four selections on SH402 ...
M74HCT132 - STMicroelectronics
M74HCT132 - STMicroelectronics

UJT
UJT

... • UJT consists of a block of lightly-doped (high resistance) nmaterial with a p-material grown into its side. It is often used as a trigger device for SCRs and triacs. Its characteristics make it very useful in many industrial circuits, such as timers, oscillators, waveform generators and gate contr ...
pn junction diode - kcpe-kcse
pn junction diode - kcpe-kcse

... electrical contact, the applied voltage has become high enough to generate an electrical arc straight through the crystal. This will destroy the diode. It is also possible to allow too much current to flow through the diode in the forward direction. The crystal is not a perfect conductor; it does ex ...
CN-0123 利用自动校准技术将16通道、16位DAC AD5360的失调电压降至1 mV以下
CN-0123 利用自动校准技术将16通道、16位DAC AD5360的失调电压降至1 mV以下

... programmable to connect any of the 16 DAC outputs to a single pin, the MON_OUT pin. The multiplexer switches have a low but finite on resistance, RON so that any current drawn from MON_OUT creates a voltage drop across RON and, therefore, an output error. To prevent this, MON_OUT is buffered by an A ...
Impedance and Ohm`s Law
Impedance and Ohm`s Law

Safe isolation procedures
Safe isolation procedures

Inductive Load Arc Suppression
Inductive Load Arc Suppression

... When determining component specifications for a snubber, there are a few additional items to consider beyond the previously mentioned checks of arc evaluation, maximum capacitor voltage, and life. When the switch contacts are open, a current will be flowing through the snubber network.It should be v ...
ALTEK MILLIAMP LOOP CALIBRATOR MODEL 334
ALTEK MILLIAMP LOOP CALIBRATOR MODEL 334

... Altek’s Model 334 Loop Calibrator has been designed to check, calibrate and trouble shoot all the signals present within a standard 4 to 20 milliamp process control loop. A 24 mA Source, mA meter, 2-Wire Transmitter Simulator and a DC Volt meter are combined into one easy-to-operate instrument. Dual ...
NM485SLC
NM485SLC

How to design an inexpensive HART transmitter By Thomas Kugelstadt Applications Manager
How to design an inexpensive HART transmitter By Thomas Kugelstadt Applications Manager

Rarely Asked Questions R A Q ’ s Q.
Rarely Asked Questions R A Q ’ s Q.

Physics for Scientists & Engineers 1
Physics for Scientists & Engineers 1

... 4 resistors with R1=20 , R2=20 , R3=30, and R4=8 .  What is the current i2 through R2? Key Idea 1: R2 and R3 are in parallel, so they have the same voltage drop V2=V3=V23 Key Idea 2: R1, R23 and R4 are in series so they have the same current V23=iR23 =(0.3 A)(12)=3.6 V ...
Formative assessment marking key: Light Module Quiz
Formative assessment marking key: Light Module Quiz

... answers to each question are provided. These answers show different levels of conceptual development from low (*), medium (**) to high (***). This information can be used in a formative manner to match students’ levels of conceptual development to activities of appropriate conceptual challenge desig ...
Major Megger Insulation Resistance Testers
Major Megger Insulation Resistance Testers

... The range of insulation test voltages available allows one instrument to be used for a variety of applications. For example, installations and equipment can be tested at 1000 V d.c. when this requirement is specified, also aircraft and tele-communications equipment can be tested at the relatively lo ...
< 1 ... 2430 2431 2432 2433 2434 2435 2436 2437 2438 ... 2982 >

Opto-isolator



In electronics, an opto-isolator, also called an optocoupler, photocoupler, or optical isolator, is a component that transfers electrical signals between two isolated circuits by using light. Opto-isolators prevent high voltages from affecting the system receiving the signal. Commercially available opto-isolators withstand input-to-output voltages up to 10 kV and voltage transients with speeds up to 10 kV/μs.A common type of opto-isolator consists of an LED and a phototransistor in the same opaque package. Other types of source-sensor combinations include LED-photodiode, LED-LASCR, and lamp-photoresistor pairs. Usually opto-isolators transfer digital (on-off) signals, but some techniques allow them to be used with analog signals.