• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Application Examples
Application Examples

... - 50 % - as that given in example 1. In this example, dimensioning of the interface is launched from the high state at the output of the optocoupler. In the high state a non-operate current of the IIH - of maximum 40 μA - may flow in the TTL input. If RL selection is too high, the entire non-operate ...
Local Oscillator / Harmonic Mixer Frequency Measurement System
Local Oscillator / Harmonic Mixer Frequency Measurement System

... frequency counter. Realize that this system cannot distinguish whether the microwaves input are below or above 140 Ghz. This can be determined, however, by increasing or decreasing the frequency of the microwaves (using the mechanical bellows on the EIO) and observing the effect this has on the meas ...
Absorb current spikes and noise with a simple technique
Absorb current spikes and noise with a simple technique

... Data sheets for most voltage references have an outputvoltage-noise specification over a 0.1- to 10-Hz frequency range. Some manufacturers include specifications for the voltage-reference output-noise density. This specification usually refers to noise in the broadband region, such as the noise den ...
DC1602A - Linear Technology
DC1602A - Linear Technology

Abstract - PG Embedded systems
Abstract - PG Embedded systems

The Future of Sound. Made Perfectly Clear.
The Future of Sound. Made Perfectly Clear.

... On-board electronics ensures fast, easy set up and complete control. An improved version of KV2 Audio’s switch mode, current enhancing low frequency amplifier has been developed for the EX10. The new configuration improves overall system efficiency and increases output allowing passive radiation of hea ...
ADC10321 ADC10321 10-Bit, 20MSPS, 98mW A/D Converter with Internal Sample and... Literature Number: SNAS028E
ADC10321 ADC10321 10-Bit, 20MSPS, 98mW A/D Converter with Internal Sample and... Literature Number: SNAS028E

B42031119
B42031119

... High-power rectifiers do not have a wide choice of switching devices because there are not the combination of IGBTs without the antiparallel many kinds of the switching devices for high-power diode and the SiC diodes is an other viable solution capacity. Generally, the full-bridge rectifier in hight ...
ADM560 数据手册DataSheet 下载
ADM560 数据手册DataSheet 下载

... rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect ...
lab8 - ECE UC Davis
lab8 - ECE UC Davis

... oscilloscope to measure the magnitude of the open loop gain vs. frequency from 50 Hz to 10 kHz. Also, use the oscilloscope to measure the phase of the gain vs. frequency from 50 Hz to 10 kHz. The phase can be measured by displaying the input and output signals on the oscilloscope and measuring the t ...
Detectors
Detectors

ID2 Intelligent 2 Wire Fire Detection
ID2 Intelligent 2 Wire Fire Detection

... advanced 2 wire system on the market. We can now provide a system that gives all of the benefits associated with a ‘2 Wire’ installation (less cable, quicker installation, cost savings on labour/product) and has the facility to ‘I.D.’ the devices. The system is built on the proven communication prot ...
TRX Data Sheet
TRX Data Sheet

... The Haes 1A and 2.5A ‘TRX’ transformer rectifier power supplies are suitable for applications requiring a simple regulated 24vdc supply, where the charging of standby batteries is not required. Typical applications include door retaining magnets, electromagnetic door closers or analogue system inter ...
Power Electronics
Power Electronics

PDF
PDF

Final Exam 2015/2016 i File - e
Final Exam 2015/2016 i File - e

Physical Science Chapter 6 (Electricity) Notes
Physical Science Chapter 6 (Electricity) Notes

... be conducted. There are two types of cells: dry and wet. a) Dry cell – the electrolyte is a paste. b) Wet cell – the electrolyte is a liquid. 5) Battery – a collection of two or more electric cells. 6) Resistance-- is the tendency for material to oppose the flow of electrons, changing electrical ene ...
Wave Light Test
Wave Light Test

... 7. A simple optical fibre consists of a cylindrical tube of transparent material of refractive index 1.50 surrounded by air. A light ray is retained within the fibre by total internal reflection. The light ray travels down the tube striking the wall at an angle, . ...
ground bond - high voltage insulation resistance
ground bond - high voltage insulation resistance

... desirable to make a distinction between real and total current. Total current is the vector sum of resistive and capacitive leakage current (see picture on the right). If the tester monitors only the total current, a substantial change in real current can often go undetected. The ability to separate ...
TeamCommonGroundPhas2 - Department of Applied
TeamCommonGroundPhas2 - Department of Applied

... On the MC33926 Motor Driver Carrier you want to find pin 1 that says Vin. From Vin we will be getting all of the battery voltage, which can range from 0 to 10 volts. Since the battery can charge higher than what the processor is rated for there needs to be a regulator. The ColdFire needs 5 volts whi ...
OPA604
OPA604

... offset. The OPA604 can replace many other amplifiers by leaving the external null circuit unconnected. The OPA604 is unity-gain stable, making it easy to use in a wide range of circuitry. Applications with noisy or high impedance power supply lines may require decoupling capacitors close to the devi ...
Lassiter-PLC - CUE Web Summary for halldweb.jlab.org
Lassiter-PLC - CUE Web Summary for halldweb.jlab.org

... PLC Programming • Programming can be done by a combination of computer languages: ladder logic, function blocks, flow diagrams, Basic and even C to name a few. • Programming is sequential for the most part. • Certain tasks(programs) can be given higher priority (scan rate). ...
T3300 Voltage Relay
T3300 Voltage Relay

... pick-up level, and another LED indicates at over voltage pick-up level. Also two LEDs indicate when the respective output relays are operated on fault level. The green power LED indicates when the voltage relay is on power. The connection diagram shows the system de-energized. ...
unit08 - electromaths
unit08 - electromaths

... EXPRESSING A RATIO IN ITS SIMPLEST FORM Example 2 Two light globes are rated at 80W and 40W. The ratings are in the ratio 80:40. However, it is usual to express ratios, like fractions, in their lowest terms. Therefore is the same as and ...
Electric Circuits
Electric Circuits

< 1 ... 2396 2397 2398 2399 2400 2401 2402 2403 2404 ... 2982 >

Opto-isolator



In electronics, an opto-isolator, also called an optocoupler, photocoupler, or optical isolator, is a component that transfers electrical signals between two isolated circuits by using light. Opto-isolators prevent high voltages from affecting the system receiving the signal. Commercially available opto-isolators withstand input-to-output voltages up to 10 kV and voltage transients with speeds up to 10 kV/μs.A common type of opto-isolator consists of an LED and a phototransistor in the same opaque package. Other types of source-sensor combinations include LED-photodiode, LED-LASCR, and lamp-photoresistor pairs. Usually opto-isolators transfer digital (on-off) signals, but some techniques allow them to be used with analog signals.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report