current - Uplift Hampton
... There is energy lost in a power line due to dissipation of energy to heat throughout the length of the cable. So DC power plants must be close to users The major advantage of AC: AC voltages can be transformed to higher or lower voltages (can be stepped up or down to provide any voltage required) by ...
... There is energy lost in a power line due to dissipation of energy to heat throughout the length of the cable. So DC power plants must be close to users The major advantage of AC: AC voltages can be transformed to higher or lower voltages (can be stepped up or down to provide any voltage required) by ...
ZXLD1322 - Diodes Incorporated
... The ZXLD1322 is an inductive DC-DC converter, with an internal switch, designed for driving single or multiple LEDs in series up to a total of 700mA output current. Applications cover input voltages ranging from 2.5V to 15V. Depending upon supply voltage and external components, this can provide up ...
... The ZXLD1322 is an inductive DC-DC converter, with an internal switch, designed for driving single or multiple LEDs in series up to a total of 700mA output current. Applications cover input voltages ranging from 2.5V to 15V. Depending upon supply voltage and external components, this can provide up ...
Bq241x0/3/4/5/8/9, bq24170/1/2, bq24133
... The bq241x0/3/4/8/9 series are highly integrated charge management devices for single-, two-, or three-, 4.2-V cells of Li-ion and Li-polymer batteries. They have integrated power FETs capable of a charging rate up to 2 A with high-accuracy voltage and current regulation. This part is featured with ...
... The bq241x0/3/4/8/9 series are highly integrated charge management devices for single-, two-, or three-, 4.2-V cells of Li-ion and Li-polymer batteries. They have integrated power FETs capable of a charging rate up to 2 A with high-accuracy voltage and current regulation. This part is featured with ...
MAX1489E ±15kV ESD-Protected, Quad, Low-Power RS-232 Line Receiver _______________General Description
... The Machine Model for ESD testing uses a 200pF storage capacitor and zero-discharge resistance. Its objective is to mimic the stress caused by contact that occurs with handling and assembly during manufacturing. Of course, all pins (not just RS-232 inputs and outputs) require this protection during ...
... The Machine Model for ESD testing uses a 200pF storage capacitor and zero-discharge resistance. Its objective is to mimic the stress caused by contact that occurs with handling and assembly during manufacturing. Of course, all pins (not just RS-232 inputs and outputs) require this protection during ...
TL441 数据资料 dataSheet 下载
... differential output that is proportional to the sum of the logarithms of the input voltages of the two stages. The four stages may be interconnected to obtain a theoretical input voltage range of 120-dB. In practice, this permits the input voltage range typically to be greater than 80-dB with log li ...
... differential output that is proportional to the sum of the logarithms of the input voltages of the two stages. The four stages may be interconnected to obtain a theoretical input voltage range of 120-dB. In practice, this permits the input voltage range typically to be greater than 80-dB with log li ...
Circuits
... When you touch an object with a net negative charge, you may get a shock. This is because the conductor wants to get rid of its excess electrons. To do this, electrons flow through you to the ground. If the conductor had an excess positive charge, the electrons would flow from the earth to you. In e ...
... When you touch an object with a net negative charge, you may get a shock. This is because the conductor wants to get rid of its excess electrons. To do this, electrons flow through you to the ground. If the conductor had an excess positive charge, the electrons would flow from the earth to you. In e ...
MAX8855/MAX8855A Dual, 5A, 2MHz Step-Down Regulators General Description Features
... Dual, 5A, 2MHz Step-Down Regulators MAX8855/MAX8855A ...
... Dual, 5A, 2MHz Step-Down Regulators MAX8855/MAX8855A ...
Inductors & Resonance
... A common task for a transformer is to provide an AC supply at a voltage suitable for rectifying to produce a stated DC output. The number of turns on each winding determines the output voltage from the transformer. The output voltage from the secondary is proportional to the ratio of the turns on th ...
... A common task for a transformer is to provide an AC supply at a voltage suitable for rectifying to produce a stated DC output. The number of turns on each winding determines the output voltage from the transformer. The output voltage from the secondary is proportional to the ratio of the turns on th ...
GNS ESI RF2174
... series inductance formed by the output bond wires, vias, and microstrip, and 2 shunt capacitors external to the part. The optimum load impedance at the RF Output pad is 4.5-j3.9 With this match, a 50 terminal impedance is achieved. The input is internally matched to 50 with just a blocking capac ...
... series inductance formed by the output bond wires, vias, and microstrip, and 2 shunt capacitors external to the part. The optimum load impedance at the RF Output pad is 4.5-j3.9 With this match, a 50 terminal impedance is achieved. The input is internally matched to 50 with just a blocking capac ...
Student Notes - Harrisonville Schools
... 19. How many kilowatts are 2,000 watts? 20. How many kilowatts are 4,500 watts? 21. How many kilowatts are 125,000 watts? 22. How many watts are 7 kilowatts? 23. How many watts are 4.2 kilowatts? 24. Assume you have three 300 watt light bulbs outside your house and you turn the lights on at 9 p.m. a ...
... 19. How many kilowatts are 2,000 watts? 20. How many kilowatts are 4,500 watts? 21. How many kilowatts are 125,000 watts? 22. How many watts are 7 kilowatts? 23. How many watts are 4.2 kilowatts? 24. Assume you have three 300 watt light bulbs outside your house and you turn the lights on at 9 p.m. a ...
Product Selection Guide OptiMOS and StrongIRFET Combined
... performance and differentiated products according to switching frequency. For low frequency applications, OptiMOS™ 5 is the best fit when best-in-class performance is required. However, StrongIRFET™ is recommended for 20 V to 75 V applications when best-inclass performance is not essential and cost ...
... performance and differentiated products according to switching frequency. For low frequency applications, OptiMOS™ 5 is the best fit when best-in-class performance is required. However, StrongIRFET™ is recommended for 20 V to 75 V applications when best-inclass performance is not essential and cost ...
Ch23 electric Current
... ⇒ In a parallel circuit, there are multiple paths for electrons to flow. If one of the paths is broken, electrons will still flow through the ...
... ⇒ In a parallel circuit, there are multiple paths for electrons to flow. If one of the paths is broken, electrons will still flow through the ...
Standard LED Exit Sign
... The remote head capability option allows the LED unit to supply power to up to two additional 6V remote heads. Remote wattage of 14.4W available. The remote heads would then operate on the same emergency mode as the standard units (see Emergency Operation Section). ...
... The remote head capability option allows the LED unit to supply power to up to two additional 6V remote heads. Remote wattage of 14.4W available. The remote heads would then operate on the same emergency mode as the standard units (see Emergency Operation Section). ...
The MOSFET Current M..
... Since Vs 0 , we find that from the above equation, the drain voltage must be: ...
... Since Vs 0 , we find that from the above equation, the drain voltage must be: ...
Points Operation Fault
... In point machine** with meter on volts DC on either contacts D7 or D8 (whichever is made) & term A3, check for voltage. On clamplock P/U, check for voltage on bottom two links. Is there any reading? NO The fault lies between point equipment and LOC, possible cable fault. ...
... In point machine** with meter on volts DC on either contacts D7 or D8 (whichever is made) & term A3, check for voltage. On clamplock P/U, check for voltage on bottom two links. Is there any reading? NO The fault lies between point equipment and LOC, possible cable fault. ...
MAX15034 Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications General Description
... output channel of the MAX15034 drives n-channel MOSFETs and is capable of providing more than 25A of load current. The MAX15034 uses average currentmode control with a switching frequency up to 1MHz per phase where each phase is 180° out of phase with respect to the other. Out-of-phase operation res ...
... output channel of the MAX15034 drives n-channel MOSFETs and is capable of providing more than 25A of load current. The MAX15034 uses average currentmode control with a switching frequency up to 1MHz per phase where each phase is 180° out of phase with respect to the other. Out-of-phase operation res ...
Opto-isolator
In electronics, an opto-isolator, also called an optocoupler, photocoupler, or optical isolator, is a component that transfers electrical signals between two isolated circuits by using light. Opto-isolators prevent high voltages from affecting the system receiving the signal. Commercially available opto-isolators withstand input-to-output voltages up to 10 kV and voltage transients with speeds up to 10 kV/μs.A common type of opto-isolator consists of an LED and a phototransistor in the same opaque package. Other types of source-sensor combinations include LED-photodiode, LED-LASCR, and lamp-photoresistor pairs. Usually opto-isolators transfer digital (on-off) signals, but some techniques allow them to be used with analog signals.