Interface 1000 Potentiostat Brochure
... The Interface 1000TM is Gamry’s high performing value Potentiostat/Galvanostat/ZRA. It is the ideal instrument for labs on a budget doing fundamental electrochemical studies. The performance/cost ratio makes it the best choice for multichannel setups where performance cannot be sacrificed for higher ...
... The Interface 1000TM is Gamry’s high performing value Potentiostat/Galvanostat/ZRA. It is the ideal instrument for labs on a budget doing fundamental electrochemical studies. The performance/cost ratio makes it the best choice for multichannel setups where performance cannot be sacrificed for higher ...
The Microwave SDR project
... frequency multipliers with their associated circuitry and tuned circuits. The LMX2486 has a number of features that make it suitable for this application. It will operate with an input frequency of up to 4.5GHz, and has a 22-bit fractional modulus that allows division ratios with the numerator and t ...
... frequency multipliers with their associated circuitry and tuned circuits. The LMX2486 has a number of features that make it suitable for this application. It will operate with an input frequency of up to 4.5GHz, and has a 22-bit fractional modulus that allows division ratios with the numerator and t ...
70 W HID lamp ballast based on the L6569, L6385E and L6562A
... Figure 6, an Rs resistor is connected between the PFC stage and the full bridge stage. If the output voltage of the PFC stage is constant, it means the current of Rs is constant. With the proper controlling of the average current flow through Rs, the current sources from the boost converter (PFC sta ...
... Figure 6, an Rs resistor is connected between the PFC stage and the full bridge stage. If the output voltage of the PFC stage is constant, it means the current of Rs is constant. With the proper controlling of the average current flow through Rs, the current sources from the boost converter (PFC sta ...
Berko Smart Series Wall Heater
... Built-in fan delay operates when unit is turned off after heating to prolong element life. 5/2 day electronic programmable built-in thermostat adaptable to fit any life style while providing energy savings and precise temperature performance. Easy to use LED touch screen operation. Convenient remote ...
... Built-in fan delay operates when unit is turned off after heating to prolong element life. 5/2 day electronic programmable built-in thermostat adaptable to fit any life style while providing energy savings and precise temperature performance. Easy to use LED touch screen operation. Convenient remote ...
BDTIC CoolSET -F3 ICE3A2065ELJ
... CoolSET®-F3 ELJ series is the enhanced version of the LJ series. Not only retains all the features of LJ series but it also implements with special technique to make the IC more robust to the system noise which is generated during transient test, system ESD test, lightning surge test, etc. In order ...
... CoolSET®-F3 ELJ series is the enhanced version of the LJ series. Not only retains all the features of LJ series but it also implements with special technique to make the IC more robust to the system noise which is generated during transient test, system ESD test, lightning surge test, etc. In order ...
MAX11166/MAX11167 16-Bit, 500ksps/250ksps, ±5V SAR ADCs with Internal Reference in TDFN General Description
... The MAX11166/MAX11167 16-bit, 500ksps/250ksps, SAR ADCs offer excellent AC and DC performance with true bipolar input range, small size, and internal reference. The MAX11166/MAX11167 measure a Q5V (10VP-P) input range while operating from a single 5V supply. A patented charge-pump architecture allow ...
... The MAX11166/MAX11167 16-bit, 500ksps/250ksps, SAR ADCs offer excellent AC and DC performance with true bipolar input range, small size, and internal reference. The MAX11166/MAX11167 measure a Q5V (10VP-P) input range while operating from a single 5V supply. A patented charge-pump architecture allow ...
Alberta Reliability Standard Generator Operation for Maintaining Network Voltages VAR-002-AB-1.1b
... This reliability standard applies to: (a) the legal owner of a generating unit, including those that operate as a synchronous condenser, that: (i) is not part of an aggregated generating facility; (ii) has a maximum authorized real power rating greater than four point five (4.5) MW; and (iii) is dir ...
... This reliability standard applies to: (a) the legal owner of a generating unit, including those that operate as a synchronous condenser, that: (i) is not part of an aggregated generating facility; (ii) has a maximum authorized real power rating greater than four point five (4.5) MW; and (iii) is dir ...
here - Stepper Motor Controllers
... transition on the step pulse. When the EPROM input address A0 is low the EPROM outputs data associated to driver channel 1. When A0 is high data associated to driver channel 2 is output from the EPROM. This means that 128 consecutive 2 byte entities in the EPROM make up one microstep cycle, which is ...
... transition on the step pulse. When the EPROM input address A0 is low the EPROM outputs data associated to driver channel 1. When A0 is high data associated to driver channel 2 is output from the EPROM. This means that 128 consecutive 2 byte entities in the EPROM make up one microstep cycle, which is ...
Chapter 3 Special-Purpose Diodes
... Total Amplifier Frequency Response Figure (b) shows a generalized ideal response curve (Bode plot) for the BJT amplifier shown in Figure (a). The three break points at the lower critical frequencies (fc1, fc2, and fc3) are produced by the three low-frequency RC circuits formed by the coupling and b ...
... Total Amplifier Frequency Response Figure (b) shows a generalized ideal response curve (Bode plot) for the BJT amplifier shown in Figure (a). The three break points at the lower critical frequencies (fc1, fc2, and fc3) are produced by the three low-frequency RC circuits formed by the coupling and b ...
NG35 Datashhet
... NG35 complies all the legislation about CE tagging. We have two directives about electronic devices, regarding the NG35 : la 2006/42/CE (machine directive) about safety use of the devices and 2004/108/CE about electromagnetic compatibility. About the first (machine directive) electric/electronic dev ...
... NG35 complies all the legislation about CE tagging. We have two directives about electronic devices, regarding the NG35 : la 2006/42/CE (machine directive) about safety use of the devices and 2004/108/CE about electromagnetic compatibility. About the first (machine directive) electric/electronic dev ...
pdf - CHIC
... is mainly due to the trade-off between the self-resonance frequency and the quality factor, Q,of the inductors and varactors. This trade-off becomes prohibitive as the operation frequency increases. This limitation has made it more attractive to pursue alternative approaches, such as distributed osc ...
... is mainly due to the trade-off between the self-resonance frequency and the quality factor, Q,of the inductors and varactors. This trade-off becomes prohibitive as the operation frequency increases. This limitation has made it more attractive to pursue alternative approaches, such as distributed osc ...
AN-2292 Designing an Isolated Buck (Fly-Buck
... Vijay Choudhary ABSTRACT In many applications, one or more low-cost, simple to use, isolated power supplies working from input voltages up to 100 V are needed. Traditional solutions use flyback converters to generate this bias supply. Flyback designs typically utilize asymmetric transformers turns r ...
... Vijay Choudhary ABSTRACT In many applications, one or more low-cost, simple to use, isolated power supplies working from input voltages up to 100 V are needed. Traditional solutions use flyback converters to generate this bias supply. Flyback designs typically utilize asymmetric transformers turns r ...
AP IM 990-7283 MN01 EN.fm
... • Do not use the UPS as a safety disconnect. • Install appropriate strain reliefs (not supplied). Snap in type strain reliefs are recommended. • Strip wire insulation 20 mm (.75 inches) to expose the wire. Secure the exposed wire with the lug. • The jumpers use T25 Torx screws. • The terminal blocks ...
... • Do not use the UPS as a safety disconnect. • Install appropriate strain reliefs (not supplied). Snap in type strain reliefs are recommended. • Strip wire insulation 20 mm (.75 inches) to expose the wire. Secure the exposed wire with the lug. • The jumpers use T25 Torx screws. • The terminal blocks ...
RF5388 3.3V, DUAL-BAND FRONT-END MODULE Features
... The RF5388 is a single-chip dual-band integrated front-end module (FEM) for high performance WiFi applications in the 2.5GHz and 5GHz ISM bands. The RF5388 addresses the need for aggressive size reduction for a typical 802.11a/b/g RF front-end design and greatly reduces the number of components outs ...
... The RF5388 is a single-chip dual-band integrated front-end module (FEM) for high performance WiFi applications in the 2.5GHz and 5GHz ISM bands. The RF5388 addresses the need for aggressive size reduction for a typical 802.11a/b/g RF front-end design and greatly reduces the number of components outs ...
Jenis Motor AT Dan Ciri
... • Three phase transformer consists of 3 transformers. • It is connected independently or in combination of 3 transformers. • Primary and secondary windings can be connected as wye (Y) or delta (∆) • Thus, there are 4 types of connections: ...
... • Three phase transformer consists of 3 transformers. • It is connected independently or in combination of 3 transformers. • Primary and secondary windings can be connected as wye (Y) or delta (∆) • Thus, there are 4 types of connections: ...
Section 14.1 1. series circuit 2. Kirchhoff`s voltage law 3. voltage
... 3. If bulbs are wired in series, when the circuit is opened, such as when a bulb burns out, the current stops flowing everywhere in the circuit and ALL the bulbs go out. 4. The total resistance in a series circuit is the sum of the resistances in the circuit. 5. As more bulbs are added, the total re ...
... 3. If bulbs are wired in series, when the circuit is opened, such as when a bulb burns out, the current stops flowing everywhere in the circuit and ALL the bulbs go out. 4. The total resistance in a series circuit is the sum of the resistances in the circuit. 5. As more bulbs are added, the total re ...
Opto-isolator
In electronics, an opto-isolator, also called an optocoupler, photocoupler, or optical isolator, is a component that transfers electrical signals between two isolated circuits by using light. Opto-isolators prevent high voltages from affecting the system receiving the signal. Commercially available opto-isolators withstand input-to-output voltages up to 10 kV and voltage transients with speeds up to 10 kV/μs.A common type of opto-isolator consists of an LED and a phototransistor in the same opaque package. Other types of source-sensor combinations include LED-photodiode, LED-LASCR, and lamp-photoresistor pairs. Usually opto-isolators transfer digital (on-off) signals, but some techniques allow them to be used with analog signals.