MAX44265 Evaluation Kit Evaluates: MAX44265 General Description Features
... The MAX44265 evaluation kit (EV kit) provides a proven design to evaluate the MAX44265 low-power, MOS-input operational amplifier (op amp) in a 6-bump wafer-level package (WLP). The EV kit circuit is preconfigured as a noninverting amplifier, but can easily be adapted to other topologies by changing ...
... The MAX44265 evaluation kit (EV kit) provides a proven design to evaluate the MAX44265 low-power, MOS-input operational amplifier (op amp) in a 6-bump wafer-level package (WLP). The EV kit circuit is preconfigured as a noninverting amplifier, but can easily be adapted to other topologies by changing ...
Q1. A 400 μF capacitor is charged so that the voltage across its
... assigned to one of the three levels according to the following criteria. High Level (good to excellent) 5 or 6 marks The information conveyed by the answer is clearly organised, logical and coherent, using appropriate specialist vocabulary correctly. The form and style of writing is appropriate to a ...
... assigned to one of the three levels according to the following criteria. High Level (good to excellent) 5 or 6 marks The information conveyed by the answer is clearly organised, logical and coherent, using appropriate specialist vocabulary correctly. The form and style of writing is appropriate to a ...
DAC712 数据资料 dataSheet 下载
... Settling time is the total time (including slew time) for the D/A output to settle to within an error band around its final value after a change in input. Settling times are specified to within ±0.003% of Full-Scale Range (FSR) for an output step change of 20V and 1LSB. The 1LSB change is measured a ...
... Settling time is the total time (including slew time) for the D/A output to settle to within an error band around its final value after a change in input. Settling times are specified to within ±0.003% of Full-Scale Range (FSR) for an output step change of 20V and 1LSB. The 1LSB change is measured a ...
500-mA DUAL DIFFERENTIAL LINE DRIVER THS6012 FEATURES
... capable of providing 400 mA output current (min) into a 25 Ω load. These drivers can be configured differentially to drive a 50-VPP output signal over low-impedance lines. The drivers are current feedback amplifiers, designed for the high slew rates necessary to support low total harmonic distortion ...
... capable of providing 400 mA output current (min) into a 25 Ω load. These drivers can be configured differentially to drive a 50-VPP output signal over low-impedance lines. The drivers are current feedback amplifiers, designed for the high slew rates necessary to support low total harmonic distortion ...
AN1809 APPLICATION NOTE STR71x ADC DRIVING AN ANALOG KEYBOARD
... This software example manages the STR71x ADC configuration, and the key recognition using the ADC software library. After configuring the analog input as a high impedance analog input, the STR71x ADC has to be enabled by setting the ADC_EN bit in the PCU_BOOTCR register. This action is followed by s ...
... This software example manages the STR71x ADC configuration, and the key recognition using the ADC software library. After configuring the analog input as a high impedance analog input, the STR71x ADC has to be enabled by setting the ADC_EN bit in the PCU_BOOTCR register. This action is followed by s ...
martinsville,va - Martinsville, Virginia
... * No-load Tap Changer: Should be furnished with two-2 ½% full rated taps below rated high voltage and two 2-1/2% full rated taps above rated high voltage Primary bushings: Two top mounted porcelain bushings, insulated for 12,470 volts Windings: Primary windings shall be copper. Impedance shall be be ...
... * No-load Tap Changer: Should be furnished with two-2 ½% full rated taps below rated high voltage and two 2-1/2% full rated taps above rated high voltage Primary bushings: Two top mounted porcelain bushings, insulated for 12,470 volts Windings: Primary windings shall be copper. Impedance shall be be ...
MK484 SHORTWAVE RADIO
... Given that the maximum allowable supply to the MK484 should not exceed 1·8V, in conjunction with resistor R4, diodes D1 and D2 stabilise the voltage at about 1·5V. Due to the voltage drop across resistor R3, this falls to between 1·3V and 1·4V; a typically safe working voltage for the radio ...
... Given that the maximum allowable supply to the MK484 should not exceed 1·8V, in conjunction with resistor R4, diodes D1 and D2 stabilise the voltage at about 1·5V. Due to the voltage drop across resistor R3, this falls to between 1·3V and 1·4V; a typically safe working voltage for the radio ...
STD4NK100Z
... Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan Malaysia - Malta - Morocco - Philippines - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States of America www.st.com ...
... Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan Malaysia - Malta - Morocco - Philippines - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States of America www.st.com ...
Unbalanced Model and Power-Flow Analysis of Microgrids and Active Distribution Systems
... lateral models, were tested on two study-systems and the results of several case-studies are compared with those obtained from the time-domain analysis in the PSCAD/EMTDC environment. II. STEADY-STATE DER MODELS This section presents generalized sequence-component frame models of the: • three-phase, ...
... lateral models, were tested on two study-systems and the results of several case-studies are compared with those obtained from the time-domain analysis in the PSCAD/EMTDC environment. II. STEADY-STATE DER MODELS This section presents generalized sequence-component frame models of the: • three-phase, ...
An On-line Approach for Power Minimization in QoS Sensitive Systems
... context switching overhead and speed up the decision process. Our primary goal is to present competitive on-line algorithms for power minimization for streaming media applications for given hardware resource constraints: latency and synchronization constraints as well as context switching overhead. ...
... context switching overhead and speed up the decision process. Our primary goal is to present competitive on-line algorithms for power minimization for streaming media applications for given hardware resource constraints: latency and synchronization constraints as well as context switching overhead. ...
Series and Parallel Circuits
... In a series circuit, all components are connected end-to-end, forming a single path for electrons to flow. In a parallel circuit, all components are connected across each other, forming exactly two sets of electrically common points. A "branch" in a parallel circuit is a path for electric current fo ...
... In a series circuit, all components are connected end-to-end, forming a single path for electrons to flow. In a parallel circuit, all components are connected across each other, forming exactly two sets of electrically common points. A "branch" in a parallel circuit is a path for electric current fo ...
Systems-Level Trade Studies of a Dual
... Electric propulsion has been shown, in theory and in practice, to provide significant mass benefits for geosynchronous communications satellites (GEOs). In particular, the Russian Hall-effect thruster SPT-140 is well-suited to the dual demands of GEO orbit raising and stationkeeping. The GEO mass be ...
... Electric propulsion has been shown, in theory and in practice, to provide significant mass benefits for geosynchronous communications satellites (GEOs). In particular, the Russian Hall-effect thruster SPT-140 is well-suited to the dual demands of GEO orbit raising and stationkeeping. The GEO mass be ...
Catalogue PDF (1,705 KB)
... The main busbar is independently and solidly insulated for each phase. During main busbar connection no gas processing is required. Since the surface of the insulation is earth screened, there is no chance of phase-to-phase ...
... The main busbar is independently and solidly insulated for each phase. During main busbar connection no gas processing is required. Since the surface of the insulation is earth screened, there is no chance of phase-to-phase ...
SN54AHCT123A, SN74AHCT123A (Rev. G)
... the wiring between the external components and Cext and Rext/Cext terminals as short as possible. ...
... the wiring between the external components and Cext and Rext/Cext terminals as short as possible. ...
MAX1874 Dual-Input, USB/AC Adapter, 1-Cell Li+ Charger with OVP and Thermal Regulation
... external MOSFET or diodes, and accepts input voltages up to 6.5V; however, DC input overvoltage protection up to 18V can be added with a single SOT PFET. On-chip thermal limiting simplifies printed circuit board (PCB) layout and allows optimum charging rate without the thermal limits imposed by wors ...
... external MOSFET or diodes, and accepts input voltages up to 6.5V; however, DC input overvoltage protection up to 18V can be added with a single SOT PFET. On-chip thermal limiting simplifies printed circuit board (PCB) layout and allows optimum charging rate without the thermal limits imposed by wors ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.