MAX107 Dual, 6-Bit, 400Msps ADC with On-Chip, Wideband Input Amplifier General Description
... MAX107 converts the analog signals of both I and Q components to digital outputs at 400Msps while achieving a signal-to-noise ratio (SNR) of typically 37dB with an input frequency of 125MHz, and an integral nonlinearity (INL) and differential nonlinearity (DNL) of ±0.25 LSB. The MAX107 analog input ...
... MAX107 converts the analog signals of both I and Q components to digital outputs at 400Msps while achieving a signal-to-noise ratio (SNR) of typically 37dB with an input frequency of 125MHz, and an integral nonlinearity (INL) and differential nonlinearity (DNL) of ±0.25 LSB. The MAX107 analog input ...
problem #5: rates of energy transfer in rc circuits
... WARNING: A charged capacitor can discharge quickly producing a painful spark. Do not handle the capacitors by their electrical terminals or connected wires by their metal ends. Always discharge a capacitor when you are finished using it. To discharge a capacitor, use an insulated wire to briefly con ...
... WARNING: A charged capacitor can discharge quickly producing a painful spark. Do not handle the capacitors by their electrical terminals or connected wires by their metal ends. Always discharge a capacitor when you are finished using it. To discharge a capacitor, use an insulated wire to briefly con ...
NET 112: - Go Nuke
... – Very simple compared to G-M – Pulse or mean-level output – Strength of output signal is directly proportional to the # of ion pairs collected – Correlates in turn to a function of radiation energy – Signal converted to dose rate • Can detect wide range of field intensities, but… • Disadvantages of ...
... – Very simple compared to G-M – Pulse or mean-level output – Strength of output signal is directly proportional to the # of ion pairs collected – Correlates in turn to a function of radiation energy – Signal converted to dose rate • Can detect wide range of field intensities, but… • Disadvantages of ...
PDF
... mode transition. FinFET based designs are compared with MOSFET based designs on basis of different parameter like Ground bounce noise, leakage current and average power dissipation. HSPICE is the software tool used for simulation and circuit design. Keywords: Sleep method, Tri mode, Tri transistor, ...
... mode transition. FinFET based designs are compared with MOSFET based designs on basis of different parameter like Ground bounce noise, leakage current and average power dissipation. HSPICE is the software tool used for simulation and circuit design. Keywords: Sleep method, Tri mode, Tri transistor, ...
Building the High Voltage Power Supply
... let the size of this document scare you though, I just made few assumptions and tried to share the experience I had in as much detail as possible regarding this build. If you are already experienced with building DIY pedals and getting them mounted into enclosures, you are well on the way to a succe ...
... let the size of this document scare you though, I just made few assumptions and tried to share the experience I had in as much detail as possible regarding this build. If you are already experienced with building DIY pedals and getting them mounted into enclosures, you are well on the way to a succe ...
DS92LV8028 8 Channel 10:1 Serializer (Rev. I)
... Whenever one of the connected DS92LV1212, '1212A, '1224, or '1260 deserializers loses lock, it will automatically try to resynchronize to the data stream from the serializer. If the data stream is not a repetitive pattern, then the deserializer will automatically lock. For example, if the deserializ ...
... Whenever one of the connected DS92LV1212, '1212A, '1224, or '1260 deserializers loses lock, it will automatically try to resynchronize to the data stream from the serializer. If the data stream is not a repetitive pattern, then the deserializer will automatically lock. For example, if the deserializ ...
Siemens SIRIUS Relays
... ■ Freely parameterizable delay times and reset behavior ■ Actual value and fault type are permanently displayed ■ All versions have removable terminals ■ All versions have screw terminals or innovative spring-loaded terminals ...
... ■ Freely parameterizable delay times and reset behavior ■ Actual value and fault type are permanently displayed ■ All versions have removable terminals ■ All versions have screw terminals or innovative spring-loaded terminals ...
Distribution High Impedance Fault Location Using Localized Voltage
... Abstract—The detection and location of high impedance faults has historically been a difficult endeavor due to the low currents produced. However, the recent advent of distributed voltage monitoring devices, enabling access to fast-sampled, expansive voltage measurements throughout a distribution net ...
... Abstract—The detection and location of high impedance faults has historically been a difficult endeavor due to the low currents produced. However, the recent advent of distributed voltage monitoring devices, enabling access to fast-sampled, expansive voltage measurements throughout a distribution net ...
Implementing a 60-W, End-to-End PoE
... • Only loads with an unpowered, 25-kΩ signature resistance are powered. • PD operates from either polarity on either of two-pair sets (1,2 and 3,6 or 4,5 and 7,8) • PSE provides output short and overload protection. • The load is assumed to have a switching power supply input. These specifications p ...
... • Only loads with an unpowered, 25-kΩ signature resistance are powered. • PD operates from either polarity on either of two-pair sets (1,2 and 3,6 or 4,5 and 7,8) • PSE provides output short and overload protection. • The load is assumed to have a switching power supply input. These specifications p ...
QF-LGIA-Application
... Identify appropriate IEEE model block diagram of excitation system and power system stabilizer (PSS) for computer representation in power system stability simulations and the corresponding excitation system and PSS constants for use in the model. ...
... Identify appropriate IEEE model block diagram of excitation system and power system stabilizer (PSS) for computer representation in power system stability simulations and the corresponding excitation system and PSS constants for use in the model. ...
an electrothermally-driven low voltage micro switch for high
... thermoelectrostatic actuated shunt switch has been proposed and its complete dynamic operation explained. All its functional properties have been simulated through 3D finite element methods, and then high frequency parameters of the switch extracted. At the end, the fabrication process of the switch ...
... thermoelectrostatic actuated shunt switch has been proposed and its complete dynamic operation explained. All its functional properties have been simulated through 3D finite element methods, and then high frequency parameters of the switch extracted. At the end, the fabrication process of the switch ...
Risk assessment: use of standard electrical equipment
... surface resistance of skin (which is much reduced when wet). Death can be the result of the normal voltage of 240 V causing currents of greater than 30 mA to flow through the body for more than 40 ms. Minor shocks may also cause injury following involuntary muscle contraction. Burns caused by the pa ...
... surface resistance of skin (which is much reduced when wet). Death can be the result of the normal voltage of 240 V causing currents of greater than 30 mA to flow through the body for more than 40 ms. Minor shocks may also cause injury following involuntary muscle contraction. Burns caused by the pa ...
Exam III from spring 2002
... move on to the next. Partial credit will be given on all parts of this exam. This is a closed book exam. You will need a calculator. Please remember to write your name on every page. Remember to convert to meters and kilograms. To receive full credit, you must show all of your work or reasoning. At ...
... move on to the next. Partial credit will be given on all parts of this exam. This is a closed book exam. You will need a calculator. Please remember to write your name on every page. Remember to convert to meters and kilograms. To receive full credit, you must show all of your work or reasoning. At ...
MAX1185 Dual 10-Bit, 20Msps, 3V, Low-Power ADC with General Description
... The MAX1185 is a 3V, dual 10-bit analog-to-digital converter (ADC) featuring fully-differential wideband trackand-hold (T/H) inputs, driving two pipelined, nine-stage ADCs. The MAX1185 is optimized for low-power, high dynamic performance applications in imaging, instrumentation, and digital communic ...
... The MAX1185 is a 3V, dual 10-bit analog-to-digital converter (ADC) featuring fully-differential wideband trackand-hold (T/H) inputs, driving two pipelined, nine-stage ADCs. The MAX1185 is optimized for low-power, high dynamic performance applications in imaging, instrumentation, and digital communic ...
doc
... is used in accelerating the machine. Such a condition, if allowed to exist for more than a few cycles, would result in very high rotational turbine speed and catastrophic failure. So this condition must be eliminated as fast as possible, and this is an additional reason (besides effect of high curre ...
... is used in accelerating the machine. Such a condition, if allowed to exist for more than a few cycles, would result in very high rotational turbine speed and catastrophic failure. So this condition must be eliminated as fast as possible, and this is an additional reason (besides effect of high curre ...
VIR presentation File
... When a battery is totally discharged, all the electrons that were in excess on the negative side have migrated to the positive side neutralizing the positive atoms on the positive side. When this happens the battery does not have any voltage (0 volts) across its terminals and it does not have the ca ...
... When a battery is totally discharged, all the electrons that were in excess on the negative side have migrated to the positive side neutralizing the positive atoms on the positive side. When this happens the battery does not have any voltage (0 volts) across its terminals and it does not have the ca ...
lr115-s series - Mercury Lighting
... diffuser envelopes the LED light source allowing maximum light transmission while eliminating pixilations and hot spots. • Delivers a balanced amount of horizontal and vertical illumination. • Digital LED technology provides high efficacy and energy efficiency. • Multiple power and light leve ...
... diffuser envelopes the LED light source allowing maximum light transmission while eliminating pixilations and hot spots. • Delivers a balanced amount of horizontal and vertical illumination. • Digital LED technology provides high efficacy and energy efficiency. • Multiple power and light leve ...
- ibookfi.com
... The brushless, rotating-field alternator has broad range reconnectability. NEMA MG1, IEEE, and ANSI standards compliance for temperature rise and motor starting. Sustained short-circuit current of up to 300% of the rated current for up to 10 seconds. Sustained short-circuit current enabling down str ...
... The brushless, rotating-field alternator has broad range reconnectability. NEMA MG1, IEEE, and ANSI standards compliance for temperature rise and motor starting. Sustained short-circuit current of up to 300% of the rated current for up to 10 seconds. Sustained short-circuit current enabling down str ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.