Lot 3B - Construction of Substations. Technical Data sheets
... Short circuit impedance referred to the first winding in the following pairs: [Performance Guarantee] At principal tap: high voltage - low voltage ...
... Short circuit impedance referred to the first winding in the following pairs: [Performance Guarantee] At principal tap: high voltage - low voltage ...
NLSX0102 2-Bit 20 Mb/s Dual-Supply Level Translator
... are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor doe ...
... are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor doe ...
TJA1022
... A transceiver will switch to Sleep mode from Normal mode if SLPx_N is held LOW for tgotosleep. The relevant LIN transmit path is disabled as soon as SLPx_N goes LOW. Power consumption is very low when both transceivers are in Sleep mode. The voltage levels on LINx and TXDx have no effect on a transi ...
... A transceiver will switch to Sleep mode from Normal mode if SLPx_N is held LOW for tgotosleep. The relevant LIN transmit path is disabled as soon as SLPx_N goes LOW. Power consumption is very low when both transceivers are in Sleep mode. The voltage levels on LINx and TXDx have no effect on a transi ...
xenon bulb failure analysis
... the bulb starts using the “manual” or “emergency ignition” switch, but does not start otherwise, the problem is in this circuit. When using the “manual” of “emergency ignition” switch, never hold the switch longer than two seconds, as you can destroy the igniter’s high voltage transformer. In certai ...
... the bulb starts using the “manual” or “emergency ignition” switch, but does not start otherwise, the problem is in this circuit. When using the “manual” of “emergency ignition” switch, never hold the switch longer than two seconds, as you can destroy the igniter’s high voltage transformer. In certai ...
Precor Error Codes
... 5. Even though unlikely, the A.C. line frequency could actually be out of acceptable limits. This is more likely to occur in countries where A.C. power systems may not be well developed and controlled. There may be little that can be done about this condition. If the source frequency can not be corr ...
... 5. Even though unlikely, the A.C. line frequency could actually be out of acceptable limits. This is more likely to occur in countries where A.C. power systems may not be well developed and controlled. There may be little that can be done about this condition. If the source frequency can not be corr ...
5002 Model - Net
... This wire determines what the output polarity of H1/4 will be. If the door pin circuit is negative, connect to chassis ground. If the door circuit is positive, connect to a fused 12V source. IMPORTANT! The H3/A wire is not required for wiring the door locks. Depending on the type of door lock system ...
... This wire determines what the output polarity of H1/4 will be. If the door pin circuit is negative, connect to chassis ground. If the door circuit is positive, connect to a fused 12V source. IMPORTANT! The H3/A wire is not required for wiring the door locks. Depending on the type of door lock system ...
MAAT-010521 Voltage Variable Attenuator 5 - 45 GHz
... 6. Exceeding any one or combination of these limits may cause permanent damage to this device. 7. M/A-COM Technology does not recommend sustained operation near these survivability limits. ...
... 6. Exceeding any one or combination of these limits may cause permanent damage to this device. 7. M/A-COM Technology does not recommend sustained operation near these survivability limits. ...
16480 VARIABLE SPEED DRIVES
... serial communications bus. The loss-of-load condition sensing algorithm shall include a programmable time delay that will allow for motor acceleration from zero speed without signaling a false loss-of-load condition. 15. Critical frequency lockout ranges, with a minimum of 3 selectable, adjustable d ...
... serial communications bus. The loss-of-load condition sensing algorithm shall include a programmable time delay that will allow for motor acceleration from zero speed without signaling a false loss-of-load condition. 15. Critical frequency lockout ranges, with a minimum of 3 selectable, adjustable d ...
Written Pole Motors
... small motors, and miscellaneous appliances. Yet, there are small commercial and agricultural loads that require motors larger than the traditional limits of 10-15 hp. In this case, a three phase power supply is needed to for the three-phase motor load. However, it is often not economical to extend t ...
... small motors, and miscellaneous appliances. Yet, there are small commercial and agricultural loads that require motors larger than the traditional limits of 10-15 hp. In this case, a three phase power supply is needed to for the three-phase motor load. However, it is often not economical to extend t ...
Datasheet - Mouser Electronics
... Notes: 1. For power rating above 70°C, see derating curve. 2. Voltage rating shown is the rated DC continuous working voltage or the sine-wave RMS absolute maximum voltage at commercial line frequency. For DC applications the absolute maximum permissible voltage is 1.5 times the value shown for low ...
... Notes: 1. For power rating above 70°C, see derating curve. 2. Voltage rating shown is the rated DC continuous working voltage or the sine-wave RMS absolute maximum voltage at commercial line frequency. For DC applications the absolute maximum permissible voltage is 1.5 times the value shown for low ...
S280-10-11
... Recloser Description The SPEAR single-phase recloser consists of an interrupting module, with an embedded current transformer, and mechanism mounted to an aluminum head casting. The mechanism and interrupter assembly are mounted to a steel tank suitable for pole or substation mounting. The interrupt ...
... Recloser Description The SPEAR single-phase recloser consists of an interrupting module, with an embedded current transformer, and mechanism mounted to an aluminum head casting. The mechanism and interrupter assembly are mounted to a steel tank suitable for pole or substation mounting. The interrupt ...
Table of Contents 8.0
... Onsite DC power system nominal load values are specified in U.S. EPR FSAR Tables 8.3-12 through 8.3-15. {Additional site-specific loads powered from the Class 1E battery source include an additional feeder breaker on the 31/2/3/4BDD bus that provides electrical power to the Essential Service Water E ...
... Onsite DC power system nominal load values are specified in U.S. EPR FSAR Tables 8.3-12 through 8.3-15. {Additional site-specific loads powered from the Class 1E battery source include an additional feeder breaker on the 31/2/3/4BDD bus that provides electrical power to the Essential Service Water E ...
ADP1048 数据手册DataSheet 下载
... The ADP1047/ADP1048 are digital power factor correction (PFC) controllers that provide accurate input power metering capability and inrush current control for ac/dc systems. The ADP1047 is designed for single phase PFC applications; the ADP1048 is designed especially for interleaved and bridgeless P ...
... The ADP1047/ADP1048 are digital power factor correction (PFC) controllers that provide accurate input power metering capability and inrush current control for ac/dc systems. The ADP1047 is designed for single phase PFC applications; the ADP1048 is designed especially for interleaved and bridgeless P ...
Class 8839 Enclosed ALTIVAR 66 Specifications
... shall be matched to the kVAR demand such that the true power factor does not exceed 0.95 lagging. The capacitors shall not affect steady state operation of the VFD while operating from either utility or generator power. The switch-in of the filter shall not create power source transient disturbances ...
... shall be matched to the kVAR demand such that the true power factor does not exceed 0.95 lagging. The capacitors shall not affect steady state operation of the VFD while operating from either utility or generator power. The switch-in of the filter shall not create power source transient disturbances ...
MAX6315 Open-Drain SOT µP Reset Circuit ________________General Description ____________________________Features
... A microprocessor’s (µP’s) reset input starts the µP in a known state. The MAX6315 asserts reset to prevent code-execution errors during power-up, powerdown, or brownout conditions. RESET is guaranteed to be a logic-low for V CC > 1V (see the Electrical Characteristics table). Once VCC exceeds the re ...
... A microprocessor’s (µP’s) reset input starts the µP in a known state. The MAX6315 asserts reset to prevent code-execution errors during power-up, powerdown, or brownout conditions. RESET is guaranteed to be a logic-low for V CC > 1V (see the Electrical Characteristics table). Once VCC exceeds the re ...
MP-5400 Series Electronic Positive Positioning Hydraulic Actuator
... crank arm. To ensure that the damper closes completely, make adjustments so that the actuator is l/l 6” (1.6 mm) from the extended end of stroke when the damper closes. Verify and, if necessary, make final adjustments during system checkout. 8. For normally closed dampers, rotate the damper crank ar ...
... crank arm. To ensure that the damper closes completely, make adjustments so that the actuator is l/l 6” (1.6 mm) from the extended end of stroke when the damper closes. Verify and, if necessary, make final adjustments during system checkout. 8. For normally closed dampers, rotate the damper crank ar ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.