OMRON - Documentation: Automates programmables
... allowing faster line speeds as well as multi-product/small-lot production. ...
... allowing faster line speeds as well as multi-product/small-lot production. ...
Chaper 4
... Applying the law of diffusion, we can determine the charge flow across the base region into the collector. The equation above shows that the transistor is indeed a voltage-controlled element, thus a good candidate as an amplifier. CH4 ...
... Applying the law of diffusion, we can determine the charge flow across the base region into the collector. The equation above shows that the transistor is indeed a voltage-controlled element, thus a good candidate as an amplifier. CH4 ...
MAX811/MAX812 4-Pin µP Voltage Monitors with Manual Reset Input ________________General Description
... power-down, and brownout conditions, the MAX811/ MAX812 are relatively immune to short duration negative-going VCC transients (glitches). Figure 1 shows typical transient durations vs. reset comparator overdrive, for which the MAX811/MAX812 do not generate a reset pulse. This graph was generated usi ...
... power-down, and brownout conditions, the MAX811/ MAX812 are relatively immune to short duration negative-going VCC transients (glitches). Figure 1 shows typical transient durations vs. reset comparator overdrive, for which the MAX811/MAX812 do not generate a reset pulse. This graph was generated usi ...
8-bit PIC® Microcontroller Solutions
... Microchip’s High Performance Architecture encompasses the PIC18 family of devices. These microcontrollers utilize a 16-bit program word architecture with 18 to 80-pin package options. The PIC18 devices are high performance microcontrollers with integrated A/D converters. All PIC18 microcontrollers i ...
... Microchip’s High Performance Architecture encompasses the PIC18 family of devices. These microcontrollers utilize a 16-bit program word architecture with 18 to 80-pin package options. The PIC18 devices are high performance microcontrollers with integrated A/D converters. All PIC18 microcontrollers i ...
3.2 List of Faults and Alarms
... - carry out a POWER ON (power off/on) for all components. - check configuration and signals of the blocks in FBLOCKS. - check configuration and signals of DCC charts. - upgrade firmware to later version. - contact the Hotline. ...
... - carry out a POWER ON (power off/on) for all components. - check configuration and signals of the blocks in FBLOCKS. - check configuration and signals of DCC charts. - upgrade firmware to later version. - contact the Hotline. ...
Liebert NXL UPS 1100kVA 1+N Multi-Module
... For redundant operation, the UPS system shall have one or more modules than required to supply the full rated load. The malfunction of a module shall cause that module to be disconnected from the critical load by its output circuit breaker, and the remaining module(s) shall continue to carry the loa ...
... For redundant operation, the UPS system shall have one or more modules than required to supply the full rated load. The malfunction of a module shall cause that module to be disconnected from the critical load by its output circuit breaker, and the remaining module(s) shall continue to carry the loa ...
GRF6011 - Guerrilla RF
... GRF6011 is linear, ultra-low loss SPDT switch that has been designed with failsafe characteristics when all voltage inputs are removed. In switching mode, the device delivers IP1dB levels greater than 1 Watt along with >49 dBm IIP3 levels for both RF paths. ...
... GRF6011 is linear, ultra-low loss SPDT switch that has been designed with failsafe characteristics when all voltage inputs are removed. In switching mode, the device delivers IP1dB levels greater than 1 Watt along with >49 dBm IIP3 levels for both RF paths. ...
Fuse Facts - Marine Electricity
... fuses be operated at no more than 75% of the nominal current rating established using the controlled test conditions. These test conditions are part of UL/CSA/ANCE (Mexico) 248-14 “Fuses for Supplementary Overcurrent Protection,” whose primary objective is to specify common test standards necessary ...
... fuses be operated at no more than 75% of the nominal current rating established using the controlled test conditions. These test conditions are part of UL/CSA/ANCE (Mexico) 248-14 “Fuses for Supplementary Overcurrent Protection,” whose primary objective is to specify common test standards necessary ...
Surge Protective Devices
... b 208Y/120 series also applies to the following voltage 220Y/127. Note: When selecting a panelboard with a SurgeLoc SPD, an additional 12 circuit positions (6 adjacent mounting spaces per side) or 4.5 inches of space on each side are required. For example, if desired number of circuits is 30, a 42 c ...
... b 208Y/120 series also applies to the following voltage 220Y/127. Note: When selecting a panelboard with a SurgeLoc SPD, an additional 12 circuit positions (6 adjacent mounting spaces per side) or 4.5 inches of space on each side are required. For example, if desired number of circuits is 30, a 42 c ...
AppNote: Configuring the PAC52XX CAFE for Different Control
... Each differential amplifier in the PAC52XX has two protection comparators that can be used to trigger protection events. The state of these comparators is also accessible by the MCU by status registers. The High-speed Protection (HP) comparators compare the positive input of the differential signal ...
... Each differential amplifier in the PAC52XX has two protection comparators that can be used to trigger protection events. The state of these comparators is also accessible by the MCU by status registers. The High-speed Protection (HP) comparators compare the positive input of the differential signal ...
A Zirconium Dioxide Ammonia Microsensor Integrated with a
... on chip. Comparison to capacitive ammonia sensors, the advantages of resistive ammonia sensors include that the output signal has a high linearity and has no parasitic capacitance problem. The CMOS-MEMS technique uses the commercial CMOS process to develop MEMS devices [8,9]. Microdevices fabricated ...
... on chip. Comparison to capacitive ammonia sensors, the advantages of resistive ammonia sensors include that the output signal has a high linearity and has no parasitic capacitance problem. The CMOS-MEMS technique uses the commercial CMOS process to develop MEMS devices [8,9]. Microdevices fabricated ...
File
... Bonded type strain gauges consists of resistance elements arranged in the form of a grid of fine wire, which is cemented to a thin paper sheet or very thin Bakelite sheet, and ...
... Bonded type strain gauges consists of resistance elements arranged in the form of a grid of fine wire, which is cemented to a thin paper sheet or very thin Bakelite sheet, and ...
Datasheet
... Where the value of θJ-A for the SOT-23 package is 220˚C/W in a typical PC board mounting and the micro SMD package is 225˚C/W. Exceeding the maximum allowable dissipation will cause excessive die temperature, and the regulator will go into thermal shutdown. Note 4: For 12V option, output voltage sur ...
... Where the value of θJ-A for the SOT-23 package is 220˚C/W in a typical PC board mounting and the micro SMD package is 225˚C/W. Exceeding the maximum allowable dissipation will cause excessive die temperature, and the regulator will go into thermal shutdown. Note 4: For 12V option, output voltage sur ...
LT1996 - Precision, 100µA Gain Selectable Amplifier
... resistors, you can easily configure it into several different classical gain circuits without adding external components. The several pages of simple circuits in this data sheet demonstrate just how easy the LT1996 is to use. It can be configured into difference amplifiers, as well as into inverting ...
... resistors, you can easily configure it into several different classical gain circuits without adding external components. The several pages of simple circuits in this data sheet demonstrate just how easy the LT1996 is to use. It can be configured into difference amplifiers, as well as into inverting ...
Multi-Amp Configuration Guide
... Throughout these instructions special emphasis is placed on good safety practices. The WARNING and CAUTION graphics are used to highlight certain topics that require extra precaution. ...
... Throughout these instructions special emphasis is placed on good safety practices. The WARNING and CAUTION graphics are used to highlight certain topics that require extra precaution. ...
V / VP / W 1
... The current/voltage characteristic of a filament lamp is to be determined using a datalogger, the data then being fed into a computer to give a visual display of the characteristic. Draw the circuit diagram required for such an experiment and state what is varied so as to produce a range of values. ...
... The current/voltage characteristic of a filament lamp is to be determined using a datalogger, the data then being fed into a computer to give a visual display of the characteristic. Draw the circuit diagram required for such an experiment and state what is varied so as to produce a range of values. ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.