• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Accurate Multiple Input Switching solution for Static Timing Analysis
Accurate Multiple Input Switching solution for Static Timing Analysis

... requirements. It ensures that the design’s data will be correctly handled and will stay uncorrupted. In order to elaborate about timing verification, it is important at this stage to discuss the details of the typical design structure. A typical design uses parallel processing to improve throughput. ...
Short circuit test code TF D7 clause 12 and annex xx for survey
Short circuit test code TF D7 clause 12 and annex xx for survey

... transformer. The maximum fault current for each winding shall be determined from calculations of fault types specified in Clause 7 of IEEE Std C57.12.00 using various fault types, fault locations, and applicable system data. During testing, each winding shall be subjected to its maximum calculated f ...
Lecture 11 - The University of Arizona College of Optical Sciences
Lecture 11 - The University of Arizona College of Optical Sciences

2.0 EMC Requirements Analysis
2.0 EMC Requirements Analysis

... I certify that the information contained in this test plan is factual including description of the product operation, correct functional classifications, and acceptance criteria. I understand and agree that any subsequent changes to this test plan prior to design verification testing shall be commun ...
EVOLUTION OF DIGITALLY CONTROLLED OSCILLATORS
EVOLUTION OF DIGITALLY CONTROLLED OSCILLATORS

... oscillator. As time migrates to advance CMOS technologies, improvements on the DCO lead to high level of performance and it is because of the oscillator’s fully controlling of digital-intensive method. DCO performs better in terms of power consumption and frequency tuning range. DCO gives a linear t ...
Electrical Engineering
Electrical Engineering

... • 9.4 Rectifier Circuits • 9.5 DC Power Supplies, Zener Diodes, and Voltage Regulation ...
Aalborg Universitet Advanced Control Architectures for Intelligent MicroGrids, Part I
Aalborg Universitet Advanced Control Architectures for Intelligent MicroGrids, Part I

... conceived separately [5]-[7]. Nowadays electrical and energy engineers have to face a new scenario in which small distributed power generators and dispersed energy storage devices have to be integrated together into the grid. The new electrical grid, also named smart-grid (SG), will deliver electric ...
msm6500™ chipset solution
msm6500™ chipset solution

... 5775 MOREHOUSE DRIVE ...
Chapter 27 - KFUPM Faculty List
Chapter 27 - KFUPM Faculty List

... Q#13: A 5.0-micro-F capacitor is fully charged by connecting it to a 12-V battery. After disconnecting the battery, it was allowed for capacitor to discharge through a simple RC circuit, with a time constant of 4.0 s. What is the charge on the capacitor after one time constant has elapsed? (A1 2.2*1 ...
PolySwitch PPTC Device Principals of Operation
PolySwitch PPTC Device Principals of Operation

... surges and overtemperature faults. Like traditional fuses, these devices limit the flow of dangerously high current during fault conditions. The PolySwitch device, however, resets after the fault is cleared and power to the circuit is removed, thereby reducing warranty, service and repair costs. ...
LC717A00ARGEVK Capacitance‐Digital‐Converter IC for Electrostatic Capacitive Touch Sensors Evaluation
LC717A00ARGEVK Capacitance‐Digital‐Converter IC for Electrostatic Capacitive Touch Sensors Evaluation

... are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marki ...
A 195-Gb/s 1.2-W Inductive Inter-Chip Wireless Superconnect With
A 195-Gb/s 1.2-W Inductive Inter-Chip Wireless Superconnect With

... as the inductor diameter , chip thickness has to be reduced to less than 30 m to achieve over-3-stacked inter-chip communication. 2) Power reduction is required especially at a transmitter side to achieve parallel connections. A transmitter presented in [7] consumes 42 mW which occupies more than 90 ...
Verification of Digitally Calibrated Analog Systems with Verilog
Verification of Digitally Calibrated Analog Systems with Verilog

Questions
Questions

Electronic Systems
Electronic Systems

... Electronic systems often have to store numbers for further use in calculations. The component responsible for this task is called a memory. A flip-flop is a simple kind of memory. Flip-flops come in many models, such as S-R flip-flop, S-R NOR gate flip-flop, D type flip-flop, J-K flip-flop, etc. Fig ...
System and device for supplying desired liquid volumes by means of
System and device for supplying desired liquid volumes by means of

... flow rate thereof does also vary, and decreases when the backpressure increases. The main related drawback is that, the pump stroke number being the same, differ ent liquid volumes are delivered depending on the back pressure to be overcome and thus not only the liquid volume delivered by the given ...
Average Current Mode Control of Switching Power Supplies
Average Current Mode Control of Switching Power Supplies

... design. With a boost regulator in a high power factor application, the downslope of inductor current equals (V,&$J/L and thus varies considerably as the input voltage follows the rectified sine waveform. A fixed ramp providing adequate compensation will overcompensate much of the time, with resultin ...
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)

... transistors M8 and M9 are off and therefore they do not play any role in improving the performance of circuit and also during the reset phase these nodes have to be charged to VDD from ground. Modified Double-Tail Latch Type Comparator The schematic diagram of modified double tail latch type compara ...
Advanced Control Architectures for Intelligent MicroGrids, Part I
Advanced Control Architectures for Intelligent MicroGrids, Part I

... conceived separately [5]-[7]. Nowadays electrical and energy engineers have to face a new scenario in which small distributed power generators and dispersed energy storage devices have to be integrated together into the grid. The new electrical grid, also named smart-grid (SG), will deliver electric ...
5
5

... mV. Thus load cell signal conditioner required, which include amplifiers to boost the signal level to increase measurement resolution. Instrumentation Amplifier In a number of industrial and consumer applications, one is required to measure and control physical quantities. These physical quantities ...
Naomi electronics overview
Naomi electronics overview

... The Peltier PSU rack provides power to the peltier devices that are attached to the CCD heads. Cooling flows round the heads and controllers. To prevent the power being switched on whilst there is no cooling the power supplies are interlocked with the compressor. A flow meter is attached in line wit ...
Safety Management System
Safety Management System

... building construction and its relation to components and systems installed. It is assumed managers know how to operate plant and systems and deal with emergency and other out of control situations. Personnel will usually have full access enabling them to alter engineering settings. ...
4 Operation
4 Operation

Zener voltage
Zener voltage

Solutions to Period 12 Exercises E.1 You have four identical pieces
Solutions to Period 12 Exercises E.1 You have four identical pieces

< 1 ... 569 570 571 572 573 574 575 576 577 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report