• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Fig. 9 The energy, power and capacitance of two single strip
Fig. 9 The energy, power and capacitance of two single strip

MAX2010 500MHz to 1100MHz Adjustable RF Predistorter General Description
MAX2010 500MHz to 1100MHz Adjustable RF Predistorter General Description

... The MAX2010 is unique in that it provides up to 6dB of gain expansion and 21° of phase expansion as the input power is increased. The amount of expansion is configurable through two independent sets of control: one set adjusts the gain expansion breakpoint and slope, while the second set controls th ...
Technical datasheet Doortello... - Door phones, lift emergency call
Technical datasheet Doortello... - Door phones, lift emergency call

... Programmable call duration from 1 to 99 calls Programmable automatic setup of loudspeaker and microphone (i.e. to switch off the loudspeaker during call setup) Volume control for loudspeaker and microphone 2 integrated dry driver contacts (door opening function) Programmable automatic driver contact ...
DC/DC Converters
DC/DC Converters

LTC2175-12 - Linear Technology
LTC2175-12 - Linear Technology

... the output code flickers between 0000 0000 0000 and 1111 1111 1111 in 2’s complement output mode. Note 8: Guaranteed by design, not subject to test. Note 9: VDD = OVDD = 1.8V, fSAMPLE = 125MHz (LTC2175), 105MHz (LTC2174), or 80MHz (LTC2173), 2-lane output mode, ENC+ = singleended 1.8V square wave, E ...
Phys241ManualUnit4
Phys241ManualUnit4

...  Discuss what differential equations are and how to check their solutions. You should give an example (keep it simple).  Discuss the construction process of the two differential equations that model RC circuits with DC source. Discuss the solutions to these differential equations.  Discuss all yo ...
3. Test Board
3. Test Board

... advantages over edge-emitting lasers (EELs): it is cheap to produce, easier to test, more efficient, and has a circular emission [3]; however, they also have higher infant mortality and are less heat tolerant compared to EELs. For this project VCSELs will be assessed by their divergence angle, thres ...
V. C. Summer Nuclear Station, Units 2 and 3 COL Application
V. C. Summer Nuclear Station, Units 2 and 3 COL Application

... circuit interruption. A breaker failure may result in the loss of two circuits (one bay) if a common breaker fails and only one circuit if an outside breaker fails. As described in Subsection 8.2.1.2.2, the protective relay schemes are designed to provide redundancy such that adequate protection is ...
9350 METER
9350 METER

... Protect from potential damage from weather and construction operations. If the meters are installed in equipment, store the equipment so condensation will not form on or in it. If necessary, apply temporary heat where required to obtain suitable service conditions. ...
DMM Calibration
DMM Calibration

... Then a near-full-scale input is applied to each range, and adjustments are made if necessary. When calibrating DMMs with 4-wire resistance capability, resistance sources should have remote sensing capability, as with the Fluke 5450A Resistance Calibrator and the Fluke 5700A MFC. In the 2-wire setup, ...
Several different technologies are used in the generator portion of
Several different technologies are used in the generator portion of

... out of phase with each other. A multi-pole design will have multiple sets of three windings. The more poles there are, the slower the alternator turns for a given voltage and frequency. More poles increase the complexity of the alternator, and that in part accounts for the higher price of slow speed ...
Jeopardy
Jeopardy

S - Parameter s - HP Memory Project
S - Parameter s - HP Memory Project

A Generalized 3D Pulse Width Modulator for Multi
A Generalized 3D Pulse Width Modulator for Multi

... the medium and large capacity applications, a multi-level three-phase four-wire VSI is a better solution than a two-level one. Since the increase of the inverter levels results in a fast increase of the number of the power switches to be controlled, the implementation of the pulse width modulation ( ...
MM74C74M Datasheet - Mouser Electronics
MM74C74M Datasheet - Mouser Electronics

Tejinder full thesis
Tejinder full thesis

Practical Simulation and Modelling of Lightning Impulse Voltage
Practical Simulation and Modelling of Lightning Impulse Voltage

... Standard impulse waveform have similar characteristics as that of lightning strike and can be used for testing the strength of electrical equipment. For producing high voltage pulses Marx generator is the most popular and is most widely used method. This thesis describes the creation of a simulation ...
9330 meter
9330 meter

... Displaying web pages over a standard Internet browser. Web pages shall include real-time instantaneous values, accumulated energy values and total harmonic distortion b. Automatically e-mail alarm notifications or scheduled system status updates. E-mail messages sent by the devices can be received l ...
Requirements concerning ELECTRICAL AND ELECTRONIC
Requirements concerning ELECTRICAL AND ELECTRONIC

... These test requirements are harmonised with IEC 60092-504 “Electrical Installations in Ships - Part 504: Special features - Control and Instrumentation” and IEC 60533 “Electrical and electronic installations in ships – electromagnetic compatibility”. Electrical and electronic equipment on board ship ...
Specification Guide
Specification Guide

... the ability to operate from –16L to +16R in less than 10 seconds. 2.2.3. An electrical feedback circuit shall be incorporated with the tap-changer motor circuit and control to ensure accurate indication of tap position and number of operations. Accuracy is to be maintained for all dielectric fluids ...
Problem Set #7 solution
Problem Set #7 solution

... and the maximum voltage drop across the resistor is E0 = 20 volts, the same as the impressed voltage on the circuit. Is this a coincidence? No, indeed.√We dimly recall from AC circuit theory that when the driving frequency is 1/ LC, the capacitive and inductive reactances cancel each other out, so t ...
Kinetis KV10: 75MHz Cortex-M0+ 32/16KB Flash 32-48pin
Kinetis KV10: 75MHz Cortex-M0+ 32/16KB Flash 32-48pin

... Digital pin input voltage (except open drain pins) ...
Evaluation of ITS Equipment Generation and analysis of RF signals
Evaluation of ITS Equipment Generation and analysis of RF signals

... In pursuit of better gas mileage, the development of electric vehicles (EVs) and hybrid electric vehicles (HEVs) is ongoing, as is research into fuels cells, whose energy density exceeds that of the engines powering EVs and HEVs. In the meantime, the fields of in-vehicle data communication and compu ...
NPIC6C595 1. General description Power logic 8-bit shift register; open-drain outputs
NPIC6C595 1. General description Power logic 8-bit shift register; open-drain outputs

... extended-drain NMOS transistor whenever the output enable input (OE) is LOW. A HIGH on OE causes the outputs to assume a high-impedance OFF-state. Operation of the OE input does not affect the state of the registers. The open-drain outputs are 33 V/100 mA continuous current extended-drain NMOS trans ...
DOE Fundamentals Handbook Electrical Science Volume 4 of 4
DOE Fundamentals Handbook Electrical Science Volume 4 of 4

< 1 ... 517 518 519 520 521 522 523 524 525 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report