• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
MAX6921/MAX6931 20-Output, 76V, Serial-Interfaced VFD Tube Drivers General Description
MAX6921/MAX6931 20-Output, 76V, Serial-Interfaced VFD Tube Drivers General Description

... The MAX6921/MAX6931 are 20-output, 76V, vacuumfluorescent display (VFD) tube drivers that interface a multiplexed VFD tube to a VFD controller, such as the MAX6850–MAX6853, or to a microcontroller. The MAX6921/MAX6931 are also ideal for driving static VFD tubes or telecom relays. Data is input using ...
Lab #3 Resistive Circuits
Lab #3 Resistive Circuits

A Novel and Robust Approach for Common Mode Feedback Using
A Novel and Robust Approach for Common Mode Feedback Using

... their drain and source connected to each other. Therefore, in the case of M8 and M9 in Fig. 1, differential-mode small signal current at the front and back channels of M8 or M9 will have 180◦ phase difference. As a result, differential-mode drain and source currents of M8 or M9 will be zero in the d ...
Ion diode logics for pH control Linköping University Post Print
Ion diode logics for pH control Linköping University Post Print

... water splitting, the generated ions are transported away from the junction and replaces the previous ions of the selective channels, resulting in H+ and OH- being released at the anode and cathode, respectively (see insert in Fig. 2). For the IBMD1 presented in Fig. 2, the current rectification rati ...
Hev - Dolcera
Hev - Dolcera

... During recharging it is important to maintain the balance of battery. The balance of battery is maintained by controlling battery from ...
APPRENTICESHIP - Student Learning Outcomes 1. understand the
APPRENTICESHIP - Student Learning Outcomes 1. understand the

... as with standard construction practices related to the power industry. (ILO2, ILO3) 2. describe the hydro power generation principle and major components, AC electrical power theory, as well as transmission and distribution systems basic components and operation. (ILO1, ILO2) 3. explain interaction ...
Manual PT C. 1000/2000/3000 (EN) - AEG PS
Manual PT C. 1000/2000/3000 (EN) - AEG PS

... technology used (PFC) enables sinusoidal current consumption and therefore operation with little system disturbance. A separate, second rectifier (charging REC set up using switch mode power supply technology) is responsible for charging or trickle-charging the battery connected in the intermediate ...
manual - Zodiac
manual - Zodiac

... off) the heat pump switches off Observation: when the water attains the target temperature (leds automatically. Reminder: the 3-phase heat pump is equipped with a phase order control system (KA1) used to check that the phase order is correct at start up (and during operation) and to signal a phase o ...
Figure 6–1
Figure 6–1

Digital to Analog Conversion Using Pulse Width Modulation
Digital to Analog Conversion Using Pulse Width Modulation

... requirements, differing degrees of resolution may be used for the analog to digital conversion. The minimum voltage that can be converted using the digital to analog conversion process depends on the bit width of the digital to analog converter and the supply voltages. For example, if we are using a ...


Identifying Motor Defects Through Fault Zone Analysis
Identifying Motor Defects Through Fault Zone Analysis

... determining if an electrical problem exists or not. A mechanical operator once said, “If a problem exists with a piece of equipment, and there is an electric cable within ten feet of it, then it must be an electrical problem!” If you are involved with electric maintenance you have probably heard at ...
MAX19793 1500MHz to 6000MHz Dual Analog Voltage Variable
MAX19793 1500MHz to 6000MHz Dual Analog Voltage Variable

... can be cascaded together to yield 46.6dB of total attenuation range with a typical combined linear control slope of 16.8dB/ V (5V operation). ...
- Sacramento
- Sacramento

... This project demonstrates design of seven components that make up the radar: oscillator, power divider, high gain amplifier, low noise amplifier, transmitter antenna, receiver antenna, a mixer, and a low pass filter. Figure 1 shows a block diagram of the radar. All of the radars mentioned in the pre ...
AD9230 10-Bit, 200 MSPS/250 MSPS/300 MSPS, 1.8 V Analog
AD9230 10-Bit, 200 MSPS/250 MSPS/300 MSPS, 1.8 V Analog

... reference and sample-and-hold provide flexibility in system design. Use of a single 1.8 V supply simplifies system power supply design. Serial Port Control—Standard serial port interface supports various product functions, such as data formatting, disabling the clock duty cycle stabilizer, powerdown ...
icm_cairo
icm_cairo

... acting as a current mirror (M5), and an output buffer stage (M6) in a source-follower configuration to drive the 50Ω load. A pin photodiode is used as an input device. What is novel about this design compared with previous common-gate schemes is that it is a totalFET based approach. That is, solely ...
Fast and Accurate Fault Detection in Transmission Line Using
Fast and Accurate Fault Detection in Transmission Line Using

... with the power system state at a rate of twenty times per second. A fault occurs when two or more conductors come in contact with each other or ground in three phase systems. Faults are classified as single line-to ground faults, line-to line faults, double line-to ground faults and three phase faul ...
Sensorless Rotor Temperature Estimation of Permanent Magnet
Sensorless Rotor Temperature Estimation of Permanent Magnet

... magnet synchronous machines (PMSMs) is neodymiumiron-bore (NdFeB). This type of magnet characterizes with high intrinsic coercivity (Hci) and big maximum energy product (BHmax). Thus, PMSMs manufactured with NdFeBmagnets reveal comparatively high power density. The motor size is significantly reduce ...
Document
Document

... to optimize speed and add features. +V An example of a comparison circuit is shown. The input is compared with a reference set by the voltagedivider. Notice that there is no feedback; the op-amp is operated in open-loop, so the output will be in ...
University of Northern British Columbia Physics Program Physics 101 Laboratory Manual
University of Northern British Columbia Physics Program Physics 101 Laboratory Manual

eGauge Configuration Guide
eGauge Configuration Guide

... P: Records the power calculated from one or more current/voltage-pairs. I: Records the RMS current measured by one of the connected CTs (CT1–CT12). V: Records the RMS voltage measured by one of the lines (L1–L3). F: Records the frequency measured on one of the lines (L1–L3). #: Records numeric data. ...
TWR-K20D50M Manual
TWR-K20D50M Manual

... down. In system power‐up mode, the RTC may be powered by either the MCU regulator or the backup power  supply, VBAT.  During system power‐down, the RTC is only powered from the backup power supply, VBAT. The  TWR‐K20D50M provides a battery holder for a coin cell battery that can be used as the VBAT  ...
Measuring vibration using sound level meter Nor140
Measuring vibration using sound level meter Nor140

5403590-A Power Supply Manual.indd
5403590-A Power Supply Manual.indd

IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

... application. Thus, currently usable types of biomedical systems with sigma-delta based A/D converter need single-bit conversion hardware including decimation filter. The signal extracted out of biological source is called as Biomedical Signal. Sigma-delta modulator utilizes a negative feedback loop ...
< 1 ... 507 508 509 510 511 512 513 514 515 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report