• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
DOGXL240-7 Graphic - Electronic Assembly
DOGXL240-7 Graphic - Electronic Assembly

... Pin A2 and A3 is used to configure the device address. That means up to 4 displays can use the same I²C bus. The I²C mode has a bidirectional data transfer, i.e. data can be read back from the display’s ram. The clock-pulse rate of the CLK line can be up to 1.7 MHz, depending on power supply and wir ...
AN13 - High Speed Comparator Techniques
AN13 - High Speed Comparator Techniques

Rate Gyro Inputs - US Dynamics Corporation
Rate Gyro Inputs - US Dynamics Corporation

... gimbal rotation. All US Dynamics miniature gyroscope pickoff arrangements are implemented in the form a variable transformer. There are several variations of this basic variable transformer design used in various gyroscope designs. All transformer based pickoffs however, operate in the same fundamen ...
POWER INVERTER 5000W
POWER INVERTER 5000W

... As we cannot control the use of our products, the guarantee shall not exceed the purchase price. We make no other warranty of any kind expressed or implied. This inverter is warranted to be free from defects in material and workmanship under normal use and service for 1 year after the sale of this p ...
electricity multiple choice workshet
electricity multiple choice workshet

... Name: ________________________ Class: ___________________ Date: __________ ...
HA325 Eval guide (generic)
HA325 Eval guide (generic)

... flybacks, coils, and switching transformers that cannot be detected with other tests. Use the Ringer Test to confirm a suspect component before replacing it. The test places a capacitor in parallel with the coil and pulses the cap/coil combination. ...
Week22_revised_Motor_Control_PWM
Week22_revised_Motor_Control_PWM

... of a PWM motor signal should be 20 kHz or more to ensure that the motor whine is outside the normal human hearing range (20 – 20,000 Hz). If your motor driver circuitry uses MOSFETs, the PWM frequency should never exceed the switching speed of the MOSFET.  Because of the weight of the motor armatur ...
III. Analysis of Harmonic Loss - Massachusetts Institute of Technology
III. Analysis of Harmonic Loss - Massachusetts Institute of Technology

... Influence of harmonic on parallel capacitor group is the most significant. According to statistics, there are about 70% harmonic faults occurring in capacitor group. Research indicates that, the capacitor insulating in mineral oil can maintain two years under 5% of total distortion voltage, and diel ...
AX8052F143
AX8052F143

... 2. The choice of crystal oscillator or TCXO frequency depends on the targeted regulatory regime for TX, see separate documentation on meeting regulatory requirements. 3. To avoid spurious emission, the crystal or TCXO reference frequency should be chosen so that the RF carrier frequency is not an in ...
File
File

AN9741: Basic DACs for Electronic Engineers
AN9741: Basic DACs for Electronic Engineers

... calibration functions, and waveform generators. The DAC is a basic building block in electronic design; it serves as a digital-to-analog interface, as an analog memory, and as a multiplier, so we will study it in detail. ...
Design of DC-DC Converters using Tunable Piezoelectric
Design of DC-DC Converters using Tunable Piezoelectric

CC-STS - Crest Audio
CC-STS - Crest Audio

... The module provides 2 inputs for speaker returns and two alarm outputs (contact closures). The alarm outputs can be set to “Parallel” or “Stereo” via the “Parallel Mode” jumper. In “Parallel” mode, both alarm outputs trip when the pilot tone is absent on either (or both) channel. In “Stereo” mode, e ...
Aalborg Universitet Converters Applied to Wind Power Generation Systems
Aalborg Universitet Converters Applied to Wind Power Generation Systems

... Recent years, renewable energies, especially the off-shore wind energy and marine energies, have been drawing a lot of interest due to their features of low pollution, sustainable development, few disturbances and large capacity, which have made the expansion of energy plants from onshore to offshor ...
999016 - Parallel vs. Series Wiring
999016 - Parallel vs. Series Wiring

... Since the speakers are joined as a chain, the resistances of all the speakers are added together. LAWS OF PHYSICS: Series circuits are “voltage dividers”. Each resistance, or in our case a speaker, that is added gets a percentage of the overall voltage. Although the voltage of the entire circuit sta ...
Voltage Collapse Mitigation - pes-psrc
Voltage Collapse Mitigation - pes-psrc

Manual - ScientificsOnline.com
Manual - ScientificsOnline.com

... disconnected. All work should be done while the circuit is disconnected. After wires have been connected then students may test their circuit by closing the knife switch and seeing if the bulb lights. After a few second, the knife switch should be opened again to disconnect the circuit. “A” should b ...
R s
R s

... Oxford University Publishing common-emitter amplifier). Microelectronic Circuits by output Adel S. Sedra and(called Kenneth C. Smitha ...
AND9525/D AM Radio Amplifier with Filter using the NSVJ2394SA3
AND9525/D AM Radio Amplifier with Filter using the NSVJ2394SA3

... Semiconductor reserves the right to make changes without further notice to any products herein. ON Semiconductor makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does ON Semiconductor assume any liability arising out of the appl ...
t_line - Computer Science and Engineering
t_line - Computer Science and Engineering

... L. Zhang, H. Chen, B. Yao, K. Hamilton, and C.K. Cheng, “Repeated on-chip interconnect analysis and evaluation of delay, power and bandwidth metrics under different design goals,” IEEE International Symposium on Quality Electronic Design, 2007, pp.251-256. [Un-Terminated/Terminated T-Line] ...
BDTIC www.BDTIC.com/infineon ICB2FL01G
BDTIC www.BDTIC.com/infineon ICB2FL01G

... threshold is exceeded for longer than 500ns during preheat or run mode, an inverter over current is detected and causes a latched shut down of the IC. The ignition control is activated if the sensed slope at the LSCS pin reaches typically 205 mV/µs ± 25 mV/µs and exceeds the 0.8V threshold. This sto ...
ATC 305 Timer - Instrumentation Central
ATC 305 Timer - Instrumentation Central

... All the contacts of its two instantaneous and two delayed load switches are externally accessible at a 14 point terminal block. LONGEST LIFE With an average mechanical life expectancy of over 5,000,000 operations before the first failure, the 305 is the leader in its class. Noted for its circuit fle ...
19-ACRO Pinch Valves Glossary of Technical Terms
19-ACRO Pinch Valves Glossary of Technical Terms

What is Electric Current? Can you get a flashlight bulb to light, with a
What is Electric Current? Can you get a flashlight bulb to light, with a

... current in the body, which could occur if you accidentally make contact with a large potential difference across parts of your body. The effect of a high resistance is to limit current in a circuit if a voltage source is present; it is not dangerous at all. ...
LTC2269 - Linear Technology
LTC2269 - Linear Technology

... Note 3: When these pin voltages are taken below GND or above VDD, they will be clamped by internal diodes. This product can handle input currents of greater than 100mA below GND or above VDD without latchup. Note 4: When these pin voltages are taken below GND they will be clamped by internal diodes. ...
< 1 ... 496 497 498 499 500 501 502 503 504 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.