• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
CSI 16610 Uninterruptible Power Supply Systems
CSI 16610 Uninterruptible Power Supply Systems

- Opus
- Opus

... fig.8A is more commonly examined, [61 and [71, which has more disadvantages than fig.7D because stray inductance is not clamped as part of the seriessnubbers. Hence greater RCD-snubber capacity is required. This section is mainly about turn-off Passive snubbers or clamps to show that resetting Lseri ...
Design of a Permanent-Magnet Synchronous Generator for a 2 MW
Design of a Permanent-Magnet Synchronous Generator for a 2 MW

... types of constant-speed and variable-speed. Until the late 1990s, most wind turbines were built for constant-speed applications. The power level in these generators is below 1.5 MW and a multi-stage gearbox-to maintain a constant speed-is often used. Nowadays most wind turbine manufacturers are buil ...
Chapter 8 VCS UFSAR Table of Contents
Chapter 8 VCS UFSAR Table of Contents

... ventilation, and power to refill the PCS water storage tank and spent fuel pool if no other sources of ac power are available. An IDS spare battery bank (IDSS-DB-1A and IDSS-DB-1B) with a spare charger (IDSS-DC-1) is provided for the Class 1E battery system. In order to preserve independence of each ...
SKY77188 数据资料DataSheet下载
SKY77188 数据资料DataSheet下载

... The SKY77188 PAM is manufactured with Skyworks’ InGaP GaAs Heterojunction Bipolar Transistor (HBT) BiFET process that provides for all positive voltage DC supply operation while maintaining high efficiency and good linearity. Primary bias to the SKY77188 is supplied directly from any three-cell Ni-C ...
C1415 Controller Board Setup and Operating
C1415 Controller Board Setup and Operating

... The Bettis C1415 DC Motor Controller board is an accurate, easy to use, multi-function servo-board, intended for use with brush type motors. No calibration equipment is required to set the board. The basic concept of this controller is to read an external command signal and compare it to a feedback ...
Design Considerations for Electrical Fast Transient (EFT)
Design Considerations for Electrical Fast Transient (EFT)

... considering certain design-time principles. This application note mainly focuses on considerations for target board design. It also summarizes some important design considerations for a system and its power supply. Furthermore, it also provides firmware techniques that can be incorporated for error ...
uojcourses.awardspace.com
uojcourses.awardspace.com

... Light-emitting diodes are designed with a very large bandgap so movement of carriers across their depletion region emits photons of light energy. Lower bandgap LEDs (Light-Emitting Diodes) emit infrared radiation, while LEDs with higher bandgap energy emit visible light. Many stop lights are now sta ...
I n t e
I n t e

H044023944
H044023944

... Fig.4 shows the phase A fault current at bus 65 when a three phase to ground fault is applied at bus 65.This graph shows the superimposition of dc offset current with the ac current to give the total asymmetrical (ac+dc) current. 3. Relay Coordination When a fault occurs it may cause heavy damage to ...
modelling of electric field distribution for partial discharges in air
modelling of electric field distribution for partial discharges in air

... strength on their surface has sufficient value for the impact ionization and development of electron avalanches. Initial corona field strength is typically determined from an empirical Peek formula [3], which takes into account the radius of the phase conductors and atmospheric conditions. A model d ...
TRANSIENT VOLTAGE SURGE SUPPRESSORS 16709
TRANSIENT VOLTAGE SURGE SUPPRESSORS 16709

Extraction Current Transients: New Method of Study of Charge
Extraction Current Transients: New Method of Study of Charge

... of this TOF limitation. The capacitance higher than the geometrical one even in the MHz range represents the proof of redistribution of the applied electric field and its concentration to the contact regions [3,4] (so that TOF evaluated drift mobility is expected to be overestimated). This is also e ...
TJF1052i
TJF1052i

... The TJF1052i is a high-speed CAN transceiver that provides a galvanically isolated interface between a Controller Area Network (CAN) protocol controller and the physical two-wire CAN bus. The TJF1052i is specifically targeted at industrial applications, where galvanic isolation barriers are needed b ...
Distribution Working Group Reactive Power charging for
Distribution Working Group Reactive Power charging for

... Reactive power used by generators during periods of generating (exporting real power) has a different impact on network assets and losses compared to the reactive component of demand. The export of real power into the distribution network usually reduces the current flows as the real current from th ...
20 electric current, resistance, and ohm`s law
20 electric current, resistance, and ohm`s law

... nerve cells. A Van de Graaff generator used for nuclear research can produce a current of pure positive charges, such as protons. Figure 20.4 illustrates the movement of charged particles that compose a current. The fact that conventional current is taken to be in the direction that positive charge ...
Praesideo Power Amplifier LBB4421/10
Praesideo Power Amplifier LBB4421/10

SPEED CONTROL OF A PERMENANT MAGNET DIURECT
SPEED CONTROL OF A PERMENANT MAGNET DIURECT

... . However, modern electronic control technology, that generates the necessary variable voltage is able not only to render the D.C motor satisfactory for modern drive applications, but also greatly to extend its application and enable advantage to be taken of its low capital and maintenance costs. Ne ...
electromagnetic interference of high
electromagnetic interference of high

... Depending on the amount of voltage gradient in some areas (hanging clamps, protective circles and corners, bars and connectors) appear different stages of the corona in this order: a single cluster, and the glow breakthrough bunch of positive corona; Trichel’s or negative pulses, and the glow breakt ...
AD7264 数据手册DataSheet下载
AD7264 数据手册DataSheet下载

... approximation ADC that operates from a single 5 V power supply and features throughput rates of up to 1 MSPS per on-chip ADC (500 kSPS for the AD7264-5). Two complete ADC functions allow simultaneous sampling and conversion of two channels. Each ADC is preceded by a true differential analog input wi ...
basic electrical engineering (ee-113)
basic electrical engineering (ee-113)

a LC MOS 16-Bit Voltage Output DAC
a LC MOS 16-Bit Voltage Output DAC

... For example, when switching from Segment 1 to Segment 2, DAC1 switches from the bottom of Segment 1 to the top of Segment 2 while DAC2 stays connected to the top of Segment 1. The code driving DAC3 is automatically complemented to compensate for the inversion of its inputs. This means that any linea ...
ScaleIO Ready Node Specification Sheet
ScaleIO Ready Node Specification Sheet

... SCALEIO READY NODE HIGH-CAPACITY CONFIGURATIONS – POWEREDGE R730XD ...
General Description Features
General Description Features

... high-voltage T/R switch used in ultrasound applications. The IC includes the T/R switch, grass-clipping diodes and is able to perform both transmit and receive operations. The IC features low on-impedance in the entire ultrasound frequency range, with an extremely low 15mW (typ) power dissipation pe ...
High SCCR Overcurrent Protective Devices
High SCCR Overcurrent Protective Devices

... Weak Links and Improving SCCR The following table highlights the weak links encountered in the example on the previous page and provides Cooper Bussmann solutions, along with the added benefits that these solutions can provide for a design. This is an example of how Cooper Bussmann ...
< 1 ... 402 403 404 405 406 407 408 409 410 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report