AC or DC - Matelect
... dependent upon the depth of the defect, not the remaining uncracked portion. The result of these differences on the current path and hence measured voltage dependency, is that the change in PD with crack depth is different for the two variants. In DCPD, the response is non linear. As the remaining l ...
... dependent upon the depth of the defect, not the remaining uncracked portion. The result of these differences on the current path and hence measured voltage dependency, is that the change in PD with crack depth is different for the two variants. In DCPD, the response is non linear. As the remaining l ...
Gain Settings in the ADV7844/ADV7842:
... The AGC of the CP takes measurements of the signal on channel A. The AGC measures the depth of this synchronization pulse and compares it against a target value. It then determines an appropriate gain value for all three channels. Hard Coded RTL Values Hard coded RTL values have being calculated to ...
... The AGC of the CP takes measurements of the signal on channel A. The AGC measures the depth of this synchronization pulse and compares it against a target value. It then determines an appropriate gain value for all three channels. Hard Coded RTL Values Hard coded RTL values have being calculated to ...
The effect of aluminium additive A. G
... progress is stimulated by the desire to lower producction costs and improve quality. Lowering the exploitation costs through better protection against failures provides a strong argument for the undertaking the research intoo varistor technology. To have varistors working within their specificationn ...
... progress is stimulated by the desire to lower producction costs and improve quality. Lowering the exploitation costs through better protection against failures provides a strong argument for the undertaking the research intoo varistor technology. To have varistors working within their specificationn ...
ZX5T1951G Features and Benefits Mechanical Data
... Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. LIFE SUPPORT Diodes Incorporated products are specifically n ...
... Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. LIFE SUPPORT Diodes Incorporated products are specifically n ...
Atmel LED Drivers MSL2160/MSL2161
... timing sources. One MSL2160/1 simply generates PWM timing for itself and for the other devices in a multiple-device application. Optionally, a single external PWM signal applied to the PWM input controls all of the strings’ on times, with automatic progressive phase delay available through a single ...
... timing sources. One MSL2160/1 simply generates PWM timing for itself and for the other devices in a multiple-device application. Optionally, a single external PWM signal applied to the PWM input controls all of the strings’ on times, with automatic progressive phase delay available through a single ...
DP5000 Manual
... If the probe is farther than 25 ft (7.6 m) from the controller, a pre-amp may be desirable to reduce noise effects. If this is the case, run +5 V/-5 V as required by your preamp. Current draw must not be greater than 10 mA. If a flow switch and/or low-level tank switch is available, run wires to the ...
... If the probe is farther than 25 ft (7.6 m) from the controller, a pre-amp may be desirable to reduce noise effects. If this is the case, run +5 V/-5 V as required by your preamp. Current draw must not be greater than 10 mA. If a flow switch and/or low-level tank switch is available, run wires to the ...
Aalborg Universitet grid-connected voltage source converters
... LCL-filtered voltage source converters [1]. A wide variety of resonance damping technologies have been reported, among which active damping control methods are usually preferred over passive dampers in order to avoid extra power losses [2]. Generally, the active damping can be attained either by int ...
... LCL-filtered voltage source converters [1]. A wide variety of resonance damping technologies have been reported, among which active damping control methods are usually preferred over passive dampers in order to avoid extra power losses [2]. Generally, the active damping can be attained either by int ...
Type of Electric Motors
... • Large safety factor when selecting motor • Under-utilization of equipment • Maintain outputs at desired level even at low input voltages • High starting torque is required ...
... • Large safety factor when selecting motor • Under-utilization of equipment • Maintain outputs at desired level even at low input voltages • High starting torque is required ...
Power Quality Solutions and Energy Savings – What is Real?
... number of times where the benefits are hard to qualify. By contrast energy savings offers easy justification. ...
... number of times where the benefits are hard to qualify. By contrast energy savings offers easy justification. ...
Innovative Pencil-Type Ignition Module from Beru for the Porsche V8
... provided with a separately assembled circuit, the “smart features” were integrated into an ASIC. This allowed the number of components to be reduced from 33 to 11, Figure 5. This is better from a mechanical viewpoint and optimises EMC; further- ...
... provided with a separately assembled circuit, the “smart features” were integrated into an ASIC. This allowed the number of components to be reduced from 33 to 11, Figure 5. This is better from a mechanical viewpoint and optimises EMC; further- ...
PCA82C251 1. General description CAN transceiver for 24 V systems
... The PCA82C251 is the interface between a CAN protocol controller and the physical bus. It is primarily intended for applications up to 1 MBd in trucks and buses. The device provides differential transmit capability to the bus and differential receive capability to the CAN controller. It is fully com ...
... The PCA82C251 is the interface between a CAN protocol controller and the physical bus. It is primarily intended for applications up to 1 MBd in trucks and buses. The device provides differential transmit capability to the bus and differential receive capability to the CAN controller. It is fully com ...
Using Digital Verification Techniques on Mixed-Signal
... Voltage Generator Control As described in the previous sections, all the source generators are easily constructed and their analog value is deposited to analog node by explicitly calling their get_voltage() method at regular times. This use model is easy but can be further simplified with the generi ...
... Voltage Generator Control As described in the previous sections, all the source generators are easily constructed and their analog value is deposited to analog node by explicitly calling their get_voltage() method at regular times. This use model is easy but can be further simplified with the generi ...
VLT Series 2000/3000 Watt True Sine Wave Inverter
... Before installing the inverter, be sure the main rocker switch is set to “OFF”. Use the ON/OFF/REMOTE main rocker switch on the front panel to turn the inverter ON. Set the rocker switch to the ON position to turn the inverter ON. Notice the beeps and the activity of the indicator light display. The ...
... Before installing the inverter, be sure the main rocker switch is set to “OFF”. Use the ON/OFF/REMOTE main rocker switch on the front panel to turn the inverter ON. Set the rocker switch to the ON position to turn the inverter ON. Notice the beeps and the activity of the indicator light display. The ...
38 V, 2 A synchronous step-down switching regulator with 30 A
... The L6986 device is a step-down monolithic switching regulator able to deliver up to 2 A DC. The output voltage adjustability ranges from 0.85 V to VIN. Thanks to the P-channel MOSFET high-side power element, the device features 100% duty cycle operation. The wide input voltage range meets the speci ...
... The L6986 device is a step-down monolithic switching regulator able to deliver up to 2 A DC. The output voltage adjustability ranges from 0.85 V to VIN. Thanks to the P-channel MOSFET high-side power element, the device features 100% duty cycle operation. The wide input voltage range meets the speci ...
STWD100
... output (WDO) are valid under the condition that EN is in logical low state. The behavior of EN is common to all versions (i.e. STWD100xP, STWD100xW, STWD100xX and STWD100xY). If the EN goes high after power-up in less than tWD from the moment that VCC exceeds the timer startup voltage, VSTART, the W ...
... output (WDO) are valid under the condition that EN is in logical low state. The behavior of EN is common to all versions (i.e. STWD100xP, STWD100xW, STWD100xX and STWD100xY). If the EN goes high after power-up in less than tWD from the moment that VCC exceeds the timer startup voltage, VSTART, the W ...
Electrical Design Team Guidance Notes GN31 Pedestrian
... it is enabled by the switch sign phase from the lamp switch card. An isolator is provided for functional switching to allow the PCaTS to be turned off independently of the traffic signals. See wiring diagram. Test the output of the PSU checking the 48 volts is correct and not affected by dimming ope ...
... it is enabled by the switch sign phase from the lamp switch card. An isolator is provided for functional switching to allow the PCaTS to be turned off independently of the traffic signals. See wiring diagram. Test the output of the PSU checking the 48 volts is correct and not affected by dimming ope ...
All About Elements
... are often used in industrial and medical applications. The electrical resistance of metals decreases as temperature decreases resulting in what is called “superconductivity”. These very cold metals, or superconductors, can be used to produce very strong magnets for MRI systems. Other applications of ...
... are often used in industrial and medical applications. The electrical resistance of metals decreases as temperature decreases resulting in what is called “superconductivity”. These very cold metals, or superconductors, can be used to produce very strong magnets for MRI systems. Other applications of ...
UMZ6.8EN
... No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products" ...
... No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products" ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.