• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
buchholz relays - Transformer Accessories
buchholz relays - Transformer Accessories

... IN THE TRANSFORMER As mentioned in item 1, when oil leakages that occur in the transformer are more than 100 cm3, 300 cm3 and 400 cm3 the contact system connected to upper float activates, the reed switch connected to the second float system in the Buchholz Relay activates and sends a signal. This sig ...
Temperature Transducer Trainer ST2302 Operating
Temperature Transducer Trainer ST2302 Operating

Design of an Ultra-Low Power Wake-Up Receiver in 130nm CMOS Technology
Design of an Ultra-Low Power Wake-Up Receiver in 130nm CMOS Technology

... Wireless Sensor Networks find applications in areas such as: military, automotive and medical. The following examples are partly taken from a detailed works referred early. A summary of these areas is below: ● Sensing of wildfires: Sensor nodes can be randomly and densely placed across swaths of for ...
OpenDSS Introductory Training Level 1
OpenDSS Introductory Training Level 1

... flicker and distribution transformers. • Wind farm collector simulation. • Wind farm impact on local transmission. • Wind generation and other DG impact on switched capacitors and voltage regulators. • Open-conductor fault conditions with a variety of single-phase and three-phase transformer connect ...
Features
Features

... for a high-speed path to a given macrocell. They rely on capturing unused p-terms from neighboring macrocells to expand their product term tally, when needed. The result of this architecture is a variable timing model and the possibility of stranding unusable logic within the FB. The PLA is differen ...
Go with the Flow
Go with the Flow

... An energy source turns the armature of a generator in a magnetic field at a fixed number of revolutions per second. In the United States, electric utilities use a 60-Hz frequency. The current goes from one direction to the other and back to the first, 60 times a second. Figure 25–6a shows how an alt ...
Tektronix Curve Tracers - University of Saskatchewan
Tektronix Curve Tracers - University of Saskatchewan

... vertical axis. The vertical position control is located underneath this knob. In the top right corner is the horizontal volts/div knob. Again, as with the vertical knob, it can display the collector or base volts along the horizontal axis. The horizontal position control is located underneath this k ...
UVX Radiometer
UVX Radiometer

... This section describes how the UVX Radiometer operates. Three illustrations are included for use in conjunction with this section. Figure 2 is a Functional Block Diagram. Current to Voltage Converter The silicon detector used in the sensor may be modeled as a current source. For maximum linearity, t ...
ST-100, ST-110, ST-200, and ST-300
ST-100, ST-110, ST-200, and ST-300

... options available. The main advantages of thermistors over other electronic thermometers (thermocouples, platinum resistance thermometers) are high signal-to-noise ratio, requirement of only a single-ended channel for measurement, and low cost, while still maintaining comparable accuracy. Apogee Ins ...
Encoder Outputs Shouldn`t Fail - Nidec
Encoder Outputs Shouldn`t Fail - Nidec

... In brief, pick products with fully rated and protected outputs with adequate power, get onboard diagnostics when you can, use proper wiring techniques and cabling and ensure you have good tools on hand. This will ensure your encoders keep providing the heartbeat to keep your machinery running strong ...
Current flow controller - European Patent Office
Current flow controller - European Patent Office

... current flow control module and thereby carry out regulation of current flow in each DC power transmission medium. [0010] In embodiments of the invention, the current flow controller may include first and second main switching elements, the first main switching element being operatively connected be ...
Synthesis of Averaged Circuit Models for Switched
Synthesis of Averaged Circuit Models for Switched

... waveforms present no difficulties, consider such a two-terminal resistor characterized by v = r(i). r(Z) approaches an equality for infinitesimally small For such a resistor, the approximation vF T. This is a consequence of the small ripple assumption and the continuity of r(.). Hence, the correspon ...
FireSystem 2000 product data sheet.
FireSystem 2000 product data sheet.

... signal (total 4). When used in a voting zone format, the module inputs can be selectively programmed to provide an output signal upon activation of any two or three of the 16 inputs. When a cross-zoned configuration is required, the module will accept a maximum of eight (8) inputs or zones, and can ...
RF9810 QUAD BAND GPRS/LINEAR EDGE + 3.2V TD- SCDMA MULTI-MODE TRANSMIT MODULE
RF9810 QUAD BAND GPRS/LINEAR EDGE + 3.2V TD- SCDMA MULTI-MODE TRANSMIT MODULE

... RF9810 continues to build upon RFMD’s leading patented PowerStar® Architecture to include such features as a Power Flattening Circuit, VRAMP Filtering, VBATT Tracking, EDGE Low Power Mode. And, RFMD has integrated TD-SCDMA functionality into the RF9810, so it can be used as the transmit module in 3. ...
Sensor Interface Circuitry Design for Nuclear Applications
Sensor Interface Circuitry Design for Nuclear Applications

... result in an additional offset voltage which adds to VS, VH and VL. This additional common mode offset voltage will then be eliminated in the digital processing. A two pole passive resistive-capacitive differential filter fitted before the multiplexer helps to reduce high frequency noise on the sens ...
Qucs - A Tutorial
Qucs - A Tutorial

... In the component property dialog all the properties of a given component can be edited. A short description is given as well as there is a checkbox for each property display in schematic which can be used to add the property name and value on the schematic (or to hide it). Allowed property values Fo ...
On Power and Multi-Processors
On Power and Multi-Processors

... Both type of leakage heavily dependent on stacking and input pattern ...
Transition of Magnetic Current Limiter to Superconducting Fault
Transition of Magnetic Current Limiter to Superconducting Fault

... reactors, reconfiguration of the system such as splitting of power buses as presented in Table 1 [3]. None has proved to be efficient or economical. Usually circuit breakers are expensive, cannot interrupt fault currents until the first current comes to zero and have limited life times. The high imp ...
GENERAL DESCRIPTION FEATURES
GENERAL DESCRIPTION FEATURES

... Square-Wave Output. When enabled, the SQW pin outputs a 32.768kHz square wave. If the square wave (E32K) and battery-backup 32kHz (BB32) bits are enabled, power is provided by VBAUX when VCC is absent. Kickstart Input. This pin is used to wake up a system from an external event, such as a key closur ...
HMC607G7 数据资料DataSheet下载
HMC607G7 数据资料DataSheet下载

... [1] Reference this number when ordering complete evaluation PCB ...
Design of a Brushless Separately Excited Synchronous Motor
Design of a Brushless Separately Excited Synchronous Motor

... inverter. In fact many components are at present doubled in the rotor current controller. ...
Network Theorems - Department Of Electrical Engineering
Network Theorems - Department Of Electrical Engineering

Electrical Installations Level 2 - Pearson Schools and FE Colleges
Electrical Installations Level 2 - Pearson Schools and FE Colleges

... An a.c. supply can be obtained directly from the mains. Single phase 230 V or three phase 400 V are those generally available in the UK. The size and type of voltage required for the supply is determined by the load equipment to be used. All electrical equipment will have a plate attached to it indi ...
Figure 14 and Equations
Figure 14 and Equations

HW_4_Timing_Circuit (PPTmin)
HW_4_Timing_Circuit (PPTmin)

... into the +12V terminal on the timing circuit (should be “+” of battery) Step 15c: Connect the black wire from the switch to the red wire from the batteries by snapping together the connectors ...
< 1 ... 355 356 357 358 359 360 361 362 363 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.