• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
RS Series AC and DC Power Source User Manual
RS Series AC and DC Power Source User Manual

AK4687EQ Datasheet
AK4687EQ Datasheet

AD7693 数据手册DataSheet下载
AD7693 数据手册DataSheet下载

... Battery-powered equipment Data acquisitions Seismic data acquisition systems DVMs Instrumentation Medical instruments ...
Chapter 1: The Op Amp
Chapter 1: The Op Amp

... loop gain, signal gain, and noise gain. They are similar in nature, interrelated, but different. We will discuss them all in detail. The open-loop gain is not a precisely controlled spec. It can, and does, have a relatively large range and will be given in the specs as a typical number rather than a ...
P1237 REQUESTED INFORMATION TEST KB: FUEL PUMP DRIVER MODULE
P1237 REQUESTED INFORMATION TEST KB: FUEL PUMP DRIVER MODULE

... less, check for blown B+ circuit fuse to fuel pump relay located in battery junction box in engine compartment. If fuse is okay, repair open B+ circuit. If fuse is blown, check B+ or FPDM PWR circuit for short to ground. 9) Check For GND To FPDM Power Supply Relay Turn ignition switch to OFF positio ...
FCX591A Features Mechanical Data
FCX591A Features Mechanical Data

... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
Power Supply SITOP
Power Supply SITOP

... Efficient operation of a machine or plant requires a reliable, constant power supply. The quality and reliability of the SITOP stabilized power supplies ensure high levels of safety in DC power supply in industrial engineering and building management systems. They supply a stabilized 24 volts but al ...
Railguns
Railguns

069 - electrical conversion systems
069 - electrical conversion systems

... sufficient for a good energy yield, that is achieved by using the variable speed capability to keep the tip speed ratio λ at the value resulting in optimal energy capture. If the gearbox ratio is chosen such that the synchronous speed of the generator just falls in the middle of the speed range (in ...
Solid and stranded conductors
Solid and stranded conductors

INTERNATIONAL STANDARD IEC 60076-1
INTERNATIONAL STANDARD IEC 60076-1

Motor Protection Voltage Unbalance and Single
Motor Protection Voltage Unbalance and Single

n-lin, p-sat
n-lin, p-sat

- Pcpolytechnic
- Pcpolytechnic

The latest Soft-Starter Technology
The latest Soft-Starter Technology

...  How much power can you use for braking?  Rule of thumb: Anything more than about 300% can play havoc with power systems and cause nuisance tripping or worse.  Can the power system handle the demands of braking current for the entire duration of the stop?  How consistent does the brake time need ...
RS Series AC and DC Power Source User Manual
RS Series AC and DC Power Source User Manual

... Always ensure that facility AC input power is de-energized prior to connecting or disconnecting any cable. In normal operation, the operator does not have access to hazardous voltages within the chassis. However, depending on the user’s application configuration, HIGH VOLTAGES HAZARDOUS TO HUMAN SAF ...
LF Series Linear Variable Differential Transformer
LF Series Linear Variable Differential Transformer

NEW Products
NEW Products

... emergency mode if the utility power falls below 80% of nominal level. Models with Lead-Calcium battery shall be equipped with a pulse type charging circuitry and shall provide minimum 90 minutes of emergency lighting. The voltage/current-limiting circuitry will minimize energy consumption and shall ...
WT1800 Precision Power Analyzer Getting Started Guide User’s
WT1800 Precision Power Analyzer Getting Started Guide User’s

... To prevent fire and electric shock, only use a power cord supplied by YOKOGAWA. The main power plug must be plugged into an outlet with a protective earth terminal. Do not disable this protection by using an extension cord without protective earth grounding. Additionally, do not use the power cord s ...
Technical Information Relay Classification Electromechanical Relays
Technical Information Relay Classification Electromechanical Relays

... across the contacts by applying test currents as shown in the table below. Rated current (A) Under 0.01 ...
Colonial brochure - US Architectural Lighting
Colonial brochure - US Architectural Lighting

Lecture 2
Lecture 2

... analytical model, and graphical characteristics The symbols of the npn and pnp BJT transistors and the physical structure of the npn transistor are given in Fig. 1. We will analyze in the lectures only npn transistors. The only difference between the npn and pnp transistors is in their static states ...
FileNewTemplate
FileNewTemplate

... The failure of these two lines mechanically cascaded and caused three additional towers to fail on each line. When the line conductors fell they contacted two 230-kV lines crossing under the 500-kV rights-of-way, collapsing the 230-kV lines. The loss of the 500-kV lines activated a remedial action s ...
Arc Flash Considerations for Data Center IT Space
Arc Flash Considerations for Data Center IT Space

... Since busway replaces multiple runs of small branch wiring (each with relatively high impedance) with three large single bus bars, it has very little impedance to fault current. As a result, busway can have nearly the same fault current near the load as at the source power panels feeding them. This ...
Transducers
Transducers

< 1 ... 264 265 266 267 268 269 270 271 272 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report