2-Channel PicoGuard XP® ESD Clamp Protection Array CM1231-02SO
... products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, includi ...
... products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, includi ...
MC33882, Six Output Low-side Switch with SPI and Parallel Input
... Transient capability with external 100 resistor in series with the VPWR pin and supply. Exceeding these voltages may cause a malfunction or permanent damage to the device. Exceeding the limits on any parallel inputs or SPI pins may cause permanent damage to the device. With output OFF. ESD1 testin ...
... Transient capability with external 100 resistor in series with the VPWR pin and supply. Exceeding these voltages may cause a malfunction or permanent damage to the device. Exceeding the limits on any parallel inputs or SPI pins may cause permanent damage to the device. With output OFF. ESD1 testin ...
Oil transformers
... They can be installed on power-line poles or on the ground. Transformers are produced to comply with standard and special requirements. Slower process of insulation ageing and high stability of dielectric properties enable considerably extended life of transformer and minimal maintenance costs. ...
... They can be installed on power-line poles or on the ground. Transformers are produced to comply with standard and special requirements. Slower process of insulation ageing and high stability of dielectric properties enable considerably extended life of transformer and minimal maintenance costs. ...
Network Extensions to Remote Areas : Part 1 Planning
... 2.2.1. Overview of HVDC Transmission Most HVDC transmission schemes that are currently operating are based on the ‘classical’ current source converters. The expense of these AC/DC converters prohibits the widespread use of HVDC technology in transmission and distribution systems, except for some spe ...
... 2.2.1. Overview of HVDC Transmission Most HVDC transmission schemes that are currently operating are based on the ‘classical’ current source converters. The expense of these AC/DC converters prohibits the widespread use of HVDC technology in transmission and distribution systems, except for some spe ...
AN4704, 3-phase Sensorless BLDC Motor Control Kit with the S12
... Commutation ensures the proper direction of the phase current according to the rotor position of the BLDC motor, while the motor torque/speed only depends on the amplitude of the quasi-square current waveform. Continued control of the amplitude of the quasi-square current waveform for each phase of ...
... Commutation ensures the proper direction of the phase current according to the rotor position of the BLDC motor, while the motor torque/speed only depends on the amplitude of the quasi-square current waveform. Continued control of the amplitude of the quasi-square current waveform for each phase of ...
SH8KA2
... are presented only as guidance for Products use. Therefore, in case you use such information, you are solely responsible for it and you must exercise your own independent verification and judgment in the use of such information contained in this document. ROHM shall not be in any way responsible or ...
... are presented only as guidance for Products use. Therefore, in case you use such information, you are solely responsible for it and you must exercise your own independent verification and judgment in the use of such information contained in this document. ROHM shall not be in any way responsible or ...
Advanced Control Systems (ACS) - Dr. Imtiaz Hussain
... impurity atoms to the semi- conductor crystals in a process called doping. • By introducing impurities with a different number of valence electrons, the number of available charge carriers in the semiconductor can be increased. ...
... impurity atoms to the semi- conductor crystals in a process called doping. • By introducing impurities with a different number of valence electrons, the number of available charge carriers in the semiconductor can be increased. ...
05-10 SPEC WRITER NOTES: Use this section only
... permit load by-pass to either normal or emergency power source and complete isolation of the transfer switch, independent of transfer switch position. The switches shall conveniently and electrically bypass and isolate automatic transfer switches, which could not otherwise be safely maintained witho ...
... permit load by-pass to either normal or emergency power source and complete isolation of the transfer switch, independent of transfer switch position. The switches shall conveniently and electrically bypass and isolate automatic transfer switches, which could not otherwise be safely maintained witho ...
Old Company Name in Catalogs and Other Documents
... • The information in this document is current as of March, 2002. The information is subject to change without notice. For actual design-in, refer to the latest publications of NEC's data sheets or data books, etc., for the most up-to-date specifications of NEC semiconductor products. Not all product ...
... • The information in this document is current as of March, 2002. The information is subject to change without notice. For actual design-in, refer to the latest publications of NEC's data sheets or data books, etc., for the most up-to-date specifications of NEC semiconductor products. Not all product ...
+5V-Powered, Multichannel RS-232 Drivers/Receivers General Description Next-Generation Device Features
... General Description ...
... General Description ...
LM4120 - Texas Instruments
... ceramic output capacitors in the range of 0.022 µF to 0.047 µF. The minimum required output capacitor is 0.022 µF. These capacitors typically have an ESR of about 0.1 Ω to 0.5 Ω. Smaller ESR can be tolerated, but larger ESR cannot be tolerated. The output capacitor can be increased to improve load t ...
... ceramic output capacitors in the range of 0.022 µF to 0.047 µF. The minimum required output capacitor is 0.022 µF. These capacitors typically have an ESR of about 0.1 Ω to 0.5 Ω. Smaller ESR can be tolerated, but larger ESR cannot be tolerated. The output capacitor can be increased to improve load t ...
xbis - International Journal of Engineering and Computer Science
... Main winding supplies power. Drive roller must be in correct position because it may have no torque, run in wrong direction, blow its fuse, overheat, or simply not run if wiring is incorrect. Motor start capacitors are used to operate drive roller. Motor: X-ray machine has chain driven rollers power ...
... Main winding supplies power. Drive roller must be in correct position because it may have no torque, run in wrong direction, blow its fuse, overheat, or simply not run if wiring is incorrect. Motor start capacitors are used to operate drive roller. Motor: X-ray machine has chain driven rollers power ...
FZT491A Features Mechanical Data
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
1. What is Photon Counting
... used in immunological examinations using radioisotopes, radiation emitted from a sample is converted into low level light which must be measured with high sensitivity. In environmental measurement, test methods that make use of fluorescence and luminescence measurements are being used for hygiene mo ...
... used in immunological examinations using radioisotopes, radiation emitted from a sample is converted into low level light which must be measured with high sensitivity. In environmental measurement, test methods that make use of fluorescence and luminescence measurements are being used for hygiene mo ...
NTS0102 1. General description Dual supply translating transceiver; open drain; auto
... any of the voltage nodes (1.8 V, 2.5 V, 3.3 V and 5.0 V). Pins An and OE are referenced to VCC(A) and pins Bn are referenced to VCC(B). A LOW level at pin OE causes the outputs to assume a high-impedance OFF-state. This device is fully specified for partial power-down applications using IOFF. The IO ...
... any of the voltage nodes (1.8 V, 2.5 V, 3.3 V and 5.0 V). Pins An and OE are referenced to VCC(A) and pins Bn are referenced to VCC(B). A LOW level at pin OE causes the outputs to assume a high-impedance OFF-state. This device is fully specified for partial power-down applications using IOFF. The IO ...
generic spec for multifunction electrical power
... 2. The power supply must offer an induction coil active line filter at the input to the control power to filter out all power line noise and protect the unit from surges, transients, and other adverse conditions. 3. The Monitor shall be rated for use at temperature from –20oC to +70oC. M. The Monit ...
... 2. The power supply must offer an induction coil active line filter at the input to the control power to filter out all power line noise and protect the unit from surges, transients, and other adverse conditions. 3. The Monitor shall be rated for use at temperature from –20oC to +70oC. M. The Monit ...
Using the Siemens S65 – Display
... The display forward voltage was measured at one part to be 10.4V at 20mA current. That means a relative large voltage is needed. This voltage can be easily generated with a PWM signal generator of the µC. (Do not forget to switch on the current limitation of your power supply until the PWM generator ...
... The display forward voltage was measured at one part to be 10.4V at 20mA current. That means a relative large voltage is needed. This voltage can be easily generated with a PWM signal generator of the µC. (Do not forget to switch on the current limitation of your power supply until the PWM generator ...
Hardware Overview - La Salle University
... power does come from the power supply – except for a few parts that have a separate battery. • However, strictly speaking the device known as a power supply does not supply power, it transforms it. The source of the power is a generating station, the power is then delivered to buildings and made ava ...
... power does come from the power supply – except for a few parts that have a separate battery. • However, strictly speaking the device known as a power supply does not supply power, it transforms it. The source of the power is a generating station, the power is then delivered to buildings and made ava ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.