• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
CD74HCT4046A 数据资料 dataSheet 下载
CD74HCT4046A 数据资料 dataSheet 下载

... frequency. At this stable point the voltage on C2 remains constant as the PC2 output is in three-state and the VCO input at pin 9 is a high impedance. Also in this condition, the signal at the phase comparator pulse output (PCPOUT) is a HIGH level and so can be used for indicating a locked condition ...
Understanding RF/Microwave Solid State Switches and their Applications Application Note
Understanding RF/Microwave Solid State Switches and their Applications Application Note

... However, shunt diodes switches have limited bandwidth arising from the use of quarter wavelength transmission lines between the common junction and each shunt diode. At the midband frequency fo, where the transmission lines are λ/4 in length, the switch operates as follows: when diode D1 is forward ...
lm87.pdf
lm87.pdf

... +2.5Vin - −0.3 V to (1.4 x V+ + 0.42 V or 6 V, whichever is smaller +3.3Vin - −0.3 V to (1.8 x V+ + 0.55 V or 6 V, whichever is smaller. Note 4: When the input voltage (VIN) at any pin exceeds the power supplies (VIN < GND or VIN > V +), the current at that pin should be limited to 5 mA. The 20 mA m ...
SBR
SBR

... SBR3U30P1 - Industry leading 3A with Tj (max) of 150C in a miniature package Application: mobile phones, MP3 Players, 1/8th and 1/16th DC/DC converters, digital cameras, automotive applications Highest ESD ±16 kV HBM (Grade 3B, 16kV) rating and ±25kV ESD Protection (IEC61000-4-2 Level 4, Air Discha ...
hotcontrol® Temperature Controller C 148
hotcontrol® Temperature Controller C 148

... LED displays, indicating process value and set point value. The Fuzzy Logic technology enables a process to reach a predetermined set point in the shortest time, with the minimum of overshoot during power-up or external load disturbance. ...
LTC2421/LTC2422 - 1-/2-Channel 20-Bit
LTC2421/LTC2422 - 1-/2-Channel 20-Bit

... Note 4: Internal Conversion Clock source with the FO pin tied to GND or to VCC or to external conversion clock source with fEOSC = 153600Hz unless otherwise specified. Note 5: Guaranteed by design, not subject to test. Note 6: Integral nonlinearity is defined as the deviation of a code from a straig ...
2. Fundamentals of Electrosurgery Part I
2. Fundamentals of Electrosurgery Part I

... (c. 980) was reported to have used a hot iron to control bleeding [3, 4]. Direct current (DC) was the first electrical energy used for medical therapeutics, first described in the mid-eighteenth century by contemporary scientists such as Benjamin Franklin and John Wesley. Indeed the techniques used ...
What is a PLC
What is a PLC

... circuits for machine control. The PLC works by looking at its inputs and depending upon their state, turning on/off its outputs. The user enters a program, usually via software, that gives the desired results. PLCs are used in many "real world" applications. If there is industry present, chances are ...
Analog Devices : Sensor Signal Conditioning, Temperature Sensors
Analog Devices : Sensor Signal Conditioning, Temperature Sensors

Analog Devices : Sensor Signal Conditioning, Temperature Sensors
Analog Devices : Sensor Signal Conditioning, Temperature Sensors

... kovar/copper [kovar is the alloy used for IC leadframes] and aluminum/kovar [at the bond inside the IC]), it is obvious that in practical circuits the problem is even more complex, and it is necessary to take extreme care to ensure that all the junction pairs in the circuitry around a thermocouple, ...
Range and General Features ClassA HEADENDS
Range and General Features ClassA HEADENDS

... • Microprocessor controlled. User friendly software (selectable language: english, spanish, french). Built-in diagnostic and error identification. Module firmware update. Firmware of the SPI-300 can also be updated through a PC. • Capacity of 500 preset memory allocations for repetitive ClassA module ...
synchro/resolver conversion handbook
synchro/resolver conversion handbook

... resolver signals is that they present information about the angular position of a shaft in the form of relative amplitudes of a carrier wave. All signals, rotor and stator, input and output, are at the same frequency, and (except for imperfections in the components) in perfect time-phase synchroniza ...
Chapter 2
Chapter 2

... of fixed resistors (wirewound and composition) are shown in Fig. 2.12. Wirewound resistors are used when there is a need to dissipate a large amount of heat, while the composition resistors are used when large resistance is needed. The circuit symbol in Fig. 2.1 is for a fixed resistor. Variable res ...
application considerations for high resistance ground
application considerations for high resistance ground

... resistance grounding system is a simple process that can be completed in several steps. First, determine the status of the existing system. If the existing system is solidly grounded and it is desired to obtain the benefits associated with the continuity of service, one must consider all the loads a ...
Touch and Remote Control Intelligent Safety Dimmer - TLC
Touch and Remote Control Intelligent Safety Dimmer - TLC

... Note: Certain transformers may not behave according to their power rating when used with a dimmer. An overload will result in the safety features of this dimmer turning down the brightness. If so change your transformers to ones which do not appear as an overload, remove one (or some) transformer(s) ...
Chapter 4 Electrical Characteristics of CMOS
Chapter 4 Electrical Characteristics of CMOS

...  Off region (VgsVds): Cgs and Cgd become significant. These capacitances are dependent on gate voltage. Their value can be ...
8.3 Onsite Power System 8.3.1 Alternating Current Power Systems
8.3 Onsite Power System 8.3.1 Alternating Current Power Systems

... as described in Section 8.3.1.1.3. The EDGs connect to their respective divisional bus and have no automatic connection to any other division. The sequencing of large loads during LOCA-only conditions is accomplished in the same manner as the EDG load sequencing described in Section 7.3.1.2.12. Load ...
Page: 1 User`s Manual Page: 1 VERSION 1.1.07.02.2012
Page: 1 User`s Manual Page: 1 VERSION 1.1.07.02.2012

User`s Manual - Metaphase Technologies
User`s Manual - Metaphase Technologies

RevG_158_Attach
RevG_158_Attach

Power Management Selection Guide 2015 01_00
Power Management Selection Guide 2015 01_00

... High Voltage MOSFETs An efficiency optimized solution can be achieved with CoolMOS™ C6/E6 families. Both families include a gate resistor which gives a good balance in ease-of-use, efficiency and reduced EMI. For cost sensitive Consumer applications we recommend CoolMOS™ CE family. This technology o ...
ARTECHE SMART GRID
ARTECHE SMART GRID

... Instantaneous relays Output contacts change instantaneously from non-working position to working position when its coil is energized, coming back to the initial nonworking position when the coil ...
Electronics Intro
Electronics Intro

... are needed to see thi s picture. ...
Design control and protection for medium voltage switchgear  Carl-Johan Nylund
Design control and protection for medium voltage switchgear Carl-Johan Nylund

... switchgear market, ABB introduced the ZS1 to meet the specifications of each country market. ZS1 was used because it is what you will find out on the market today. Ten cabinets were needed from the ZS1 series for the switchgear. It needed to be able to transfer the energy to the load banks or the gr ...
equipotential planes, a figment
equipotential planes, a figment

... Physics. Having the same electric potential at every point.1 equipotential as used in the power industry: (conductor stringing equipment) (power line maintenance) An identical state of electrical potential for two or more items. (PE/T&D) 1048-1990, 516-1995, 524-1992, 524a-1993 equipotential plane a ...
< 1 ... 193 194 195 196 197 198 199 200 201 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report