MAX485 Low Power, Slew-Rate-Limited RS-485/RS
... The MAX485 is low-power transceivers for RS-485 and RS-422 communication. IC contains one driver and one receiver. The driver slew rates of the MAX485 is not limited, allowing them to transmit up to 2.5Mbps. These transceivers draw between 120µA and 500µA of supply current when unloaded or fully loa ...
... The MAX485 is low-power transceivers for RS-485 and RS-422 communication. IC contains one driver and one receiver. The driver slew rates of the MAX485 is not limited, allowing them to transmit up to 2.5Mbps. These transceivers draw between 120µA and 500µA of supply current when unloaded or fully loa ...
RC Circuit Delays
... through the resistor until it reaches an amount of time equal to 5 time constants or 5T and then remains fully charged. If this fully charged capacitor was now disconnected from its DC battery supply voltage it would store its energy built up during the charging process indefinitely (assuming an ide ...
... through the resistor until it reaches an amount of time equal to 5 time constants or 5T and then remains fully charged. If this fully charged capacitor was now disconnected from its DC battery supply voltage it would store its energy built up during the charging process indefinitely (assuming an ide ...
HMC358MS8G 数据资料DataSheet下载
... VCOs. The HMC358MS8G & HMC358MS8GE integrate resonators, negative resistance devices, varactor diodes, and buffer amplifiers. The VCO’s phase noise performance is excellent over temperature, shock, and process due to the oscillator’s monolithic structure. Power output is 11 dBm typical from a 3V sup ...
... VCOs. The HMC358MS8G & HMC358MS8GE integrate resonators, negative resistance devices, varactor diodes, and buffer amplifiers. The VCO’s phase noise performance is excellent over temperature, shock, and process due to the oscillator’s monolithic structure. Power output is 11 dBm typical from a 3V sup ...
BH6766FVM
... stress. Always discharge capacitors after each process or step. Always turn the IC’s power supply off before connecting it to or removing it from a jig or fixture during the inspection process. Ground the IC during assembly steps as an antistatic measure. Use similar precaution when transporting or ...
... stress. Always discharge capacitors after each process or step. Always turn the IC’s power supply off before connecting it to or removing it from a jig or fixture during the inspection process. Ground the IC during assembly steps as an antistatic measure. Use similar precaution when transporting or ...
ekonomski fakultet podgorica
... Where Vs and Is are the root mean square voltage and current ratings of the transformer secondary. The secondary VA rating VsIs is double that one of the half-wave rectifier because the full-wave rectifier with center tapped transformer can be treated as two half-wave rectifiers operating together. ...
... Where Vs and Is are the root mean square voltage and current ratings of the transformer secondary. The secondary VA rating VsIs is double that one of the half-wave rectifier because the full-wave rectifier with center tapped transformer can be treated as two half-wave rectifiers operating together. ...
Youngstown State University Department of Electrical - mh
... power transformer, modulation transformer, solid-state high voltage supply, input level control and fuse. An RF carrier frequency of 27 MHz is used. This continues to eliminate the hissing sound of the corona. The Ionofane 601 sold for 29 pounds 8 shillings ...
... power transformer, modulation transformer, solid-state high voltage supply, input level control and fuse. An RF carrier frequency of 27 MHz is used. This continues to eliminate the hissing sound of the corona. The Ionofane 601 sold for 29 pounds 8 shillings ...
File u208b | allcomponents.ru
... The Montreal Protocol ( 1987) and its London Amendments ( 1990) intend to severely restrict the use of ODSs and forbid their use within the next ten years. Various national and international initiatives are pressing for an earlier ban on these substances. TEMIC TELEFUNKEN microelectronic GmbH semico ...
... The Montreal Protocol ( 1987) and its London Amendments ( 1990) intend to severely restrict the use of ODSs and forbid their use within the next ten years. Various national and international initiatives are pressing for an earlier ban on these substances. TEMIC TELEFUNKEN microelectronic GmbH semico ...
INTRODUCTION TO DC GENERATOR
... The generated voltage depends upon the number of poles and armature winding turns. It has armature with iron core and air gap which is uniform the vicinity of the center of the pole and which becomes larger as the pole tips are approached.This construction gives a uniform flux distribution under the ...
... The generated voltage depends upon the number of poles and armature winding turns. It has armature with iron core and air gap which is uniform the vicinity of the center of the pole and which becomes larger as the pole tips are approached.This construction gives a uniform flux distribution under the ...
SAFE EXPERIMENTING IN CLASS MODERN MEASURING
... Function Generator FG 100 (230 V, 50/60 Hz) Function generator with power amplifier for use in versatile student and practical experiments covering simple harmonic oscillation, AC electricity and induction. Featuring illuminated, digital display for frequency, signal form, offset and other parameter ...
... Function Generator FG 100 (230 V, 50/60 Hz) Function generator with power amplifier for use in versatile student and practical experiments covering simple harmonic oscillation, AC electricity and induction. Featuring illuminated, digital display for frequency, signal form, offset and other parameter ...
ECE 2006 - Lecture 2
... • A circuit element having no resistance is considered to be a Short Circuit (infinite conductance) • A circuit element having infinite resistance is considered an Open Circuit (zero conductance) ...
... • A circuit element having no resistance is considered to be a Short Circuit (infinite conductance) • A circuit element having infinite resistance is considered an Open Circuit (zero conductance) ...
CAT4238AEVB CAT4238 10-LED Boost Converter Evaluation Board User's Manual
... are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor doe ...
... are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor doe ...
REC15_AL / REC25_AL
... saturation when exposed to fault currents. Furthermore, Rogowski sensors, unlike conventional current transformers, do not generate potentially hazardous voltages when the secondary is an open circuit, as the absence of an iron core ...
... saturation when exposed to fault currents. Furthermore, Rogowski sensors, unlike conventional current transformers, do not generate potentially hazardous voltages when the secondary is an open circuit, as the absence of an iron core ...
Circuits - Single-Chip Frequency Converter
... the normal operating range of the NE602. In (b),R1 drops voltage, and is used since a + 9volt battery can go higher, and a +9-volt wall supply can produce up to 11 volts. In (c),an +8-18-volt DC supply is regulated using 8.2-volt Zener Dl. ...
... the normal operating range of the NE602. In (b),R1 drops voltage, and is used since a + 9volt battery can go higher, and a +9-volt wall supply can produce up to 11 volts. In (c),an +8-18-volt DC supply is regulated using 8.2-volt Zener Dl. ...
review of electrical quantities and basic circuit elements
... That arc is current going through the air. So is a bolt of lightning during a thunderstorm. However, these events are unusual. Air is usually a good insulator and does not allow current to flow. For simplicity, we will idealize air in the following way: current never flows through air (or a hole in ...
... That arc is current going through the air. So is a bolt of lightning during a thunderstorm. However, these events are unusual. Air is usually a good insulator and does not allow current to flow. For simplicity, we will idealize air in the following way: current never flows through air (or a hole in ...
PDF
... Mode13:Sm1 and Sc2 are turned on and Sm2and Sc1 are turned off and the current iγ is negative. The boost inductor and the input DC source transfer the energy to Cockcroft Walton Voltage Multiplier through different odd diodes and are explained in the modes 13 to modes 21. Mode 14: Only diode D 17 co ...
... Mode13:Sm1 and Sc2 are turned on and Sm2and Sc1 are turned off and the current iγ is negative. The boost inductor and the input DC source transfer the energy to Cockcroft Walton Voltage Multiplier through different odd diodes and are explained in the modes 13 to modes 21. Mode 14: Only diode D 17 co ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.