• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Data Sheet
Data Sheet

Go Picture These! - Lake Area Radio Klub
Go Picture These! - Lake Area Radio Klub

... The approximate amount of change, measured in decibels (dB), of a power decrease from 12 watts to 3 watts is 6dB. T5B11 The approximate amount of change, measured in decibels (dB), of a power increase from 20 watts to 200 watts is 10 dB. T5B10 ...
TPS61042EVM-226 White LIght LED Bias
TPS61042EVM-226 White LIght LED Bias

abstract - Innovetech
abstract - Innovetech

8.  Electric Power AP1000 Design Control Document
8. Electric Power AP1000 Design Control Document

... A transmission system to supply offsite ac energy for startup and normal shutdown through a sitespecific transmission switchyard is as described in subsection 8.2.5. This offsite ac power system is not required for plant safety. [[A transformer area containing stepup transformers, unit auxiliary tra ...
PEDAL POWER 4x4
PEDAL POWER 4x4

... (1) 9V and 12V high-current output pairs. Each pair is an isolated output section providing up to 400mA. Note: The 9V and 12V outputs within a pair are not isolated from each other (their negative terminals are common). It is preferred to use only one from each pair. If using both, combined output s ...
LTC3414 - 4A, 4MHz, Monolithic Synchronous Step-Down Regulator
LTC3414 - 4A, 4MHz, Monolithic Synchronous Step-Down Regulator

... operation, the internal power MOSFETs operate intermittently at light loads. This increases efficiency by minimizing switching losses. During Burst Mode operation, the minimum peak inductor current is externally set by the voltage on the SYNC/MODE pin and the voltage on the ITH pin is monitored by t ...
Heathkit IG-72 - Orange County (California) Amateur Radio Club
Heathkit IG-72 - Orange County (California) Amateur Radio Club

... best solution prior to readily available silicon diodes. The power supply uses the 6X5 tube as a full wave rectifier producing 410 volts after a capacitor input LC filter. Filament voltage for the three tubes are provided by a 6.3 volt winding on the power transformer. ...
Neptune Branch Unit - APL
Neptune Branch Unit - APL

... 1. Shore station voltage is positive to isolate all loads (is +voltage really necessary?) 2. S4 is closed 3. Circuit could be energized from either end 4. Voltage across Z1 or Z2 is the power supply for the controller 5. S5 or S6 will close S1 or S2 6. Voltage across Z3 opens S4 after a delay 7. S1 ...
Interconnects
Interconnects

comparison of parallel resonant inverter and series resonant inverter
comparison of parallel resonant inverter and series resonant inverter

... 6. Conclusion This paper has compared the series resonant and parallel resonant AC-AC converter circuits for induction heating. Comparison between converters have confirmed that parallel resonant converter has advantages such as high efficiency, better power factor, eliminates dc component in load c ...
CMS EMU CSC policy on Grounding, Shielding and Power
CMS EMU CSC policy on Grounding, Shielding and Power

... transmitter side), the parasitic capacitance between shield and twisted pair wires creates the ground loop for AC current. The signals coming from one point of detector to another (not to control room) can be transmitted electrically as described above. Power distribution. This section is based most ...
Lab1-2015
Lab1-2015

electrical drives
electrical drives

ETS80X10.5C - AMETEK Programmable Power
ETS80X10.5C - AMETEK Programmable Power

... Always ensure that facility AC input power is de-energized prior to connecting or disconnecting any cable. In normal operation, the operator does not have access to hazardous voltages within the chassis. However, depending on the user’s application configuration, HIGH VOLTAGES HAZARDOUS TO HUMAN SAF ...
2016 Top Side Controller not Functioning (120V Systems)
2016 Top Side Controller not Functioning (120V Systems)

... Dreammaker Troubleshooting Guide - RS101 System ...
Mice_Collab_Meeting_CM28_RAL_Elec_Presentation
Mice_Collab_Meeting_CM28_RAL_Elec_Presentation

... all positions along the high current conduction path. This should include high current input conductors and all coils / windings, similar to that provided on the Decay solenoid. These monitoring points can then be measured using a quench detection circuit. (Probably the same as being designed for De ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... injection transformers. It can maintain load voltage by injecting three phase output voltages whose phase, magnitude and frequency can be controlled [2].The basic idea behind the DVR is to inject a controlled voltage generated by a converter in a series to the bus voltage by means of an injecting tr ...
Transmitter Architectures
Transmitter Architectures

Datasheet - Intersil
Datasheet - Intersil

... respective output pins and higher unwanted power dissipation in the part. Under these conditions, the temperature of the part could get very hot. ...
IECON05_Boost_Integr..
IECON05_Boost_Integr..

... Fig. 1. Typical voltage x current curve for HID lamps. In order to obtain low cost electronic ballast for HPS lamps with HPF a single stage converter was conceived. The idea is to build the PFC using the half-bridge boost rectifier working in discontinuous conducting mode (DCM) integrated with the e ...
A Novel Power Factor Control Scheme For High
A Novel Power Factor Control Scheme For High

... are usually connected in series to withstand ac line voltages is (typically 2300–6900 V). A three-phase filter capacitor required to assist GTO commutation and, at the same time, to filter out current harmonics produced by the converter. The represents transformer leakage inductance or inductance li ...
DN348 - Precise Gain Without External Resistors
DN348 - Precise Gain Without External Resistors

Design Specifications
Design Specifications

... light source, battery capacity, and battery life all meet required standards. The voltage of the light source was found using a multimeter and is representative of the two individual batteries connected in series. The current draw from the light source is the current that goes through the LED circui ...
TDA8358J Full bridge vertical deflection output circuit in LVDMOS
TDA8358J Full bridge vertical deflection output circuit in LVDMOS

< 1 ... 1818 1819 1820 1821 1822 1823 1824 1825 1826 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report