Evaluation Board User Guide UG-045
... The AD1938 evaluation board requires a power supply input of ±12 V dc and ground to the three binding posts; +12 V draws ~250 mA, and −12 V draws ~100mA. The on-board regulators provide two 3.3 V rails, one each for AVDD and DVDD for the AD1938. DVDD also supplies power for the active peripheral com ...
... The AD1938 evaluation board requires a power supply input of ±12 V dc and ground to the three binding posts; +12 V draws ~250 mA, and −12 V draws ~100mA. The on-board regulators provide two 3.3 V rails, one each for AVDD and DVDD for the AD1938. DVDD also supplies power for the active peripheral com ...
Circuit Protection Devices
... always select a fuse with a voltage rating equal to or higher than the voltage in the circuit you wish to protect. TIME DELAY RATING There are many kinds of electrical and electronic circuits that require protection. In some of these circuits, it is important to protect against temporary or transien ...
... always select a fuse with a voltage rating equal to or higher than the voltage in the circuit you wish to protect. TIME DELAY RATING There are many kinds of electrical and electronic circuits that require protection. In some of these circuits, it is important to protect against temporary or transien ...
ABSTRACT Title of Document:
... Figure 2.2: Calculated input and output pulse shape from a typical SOA................. 19 Figure 2.3: Schematic of an optical switch using XPM in an SOA........................... 20 Figure 2.4: Experimental setup for demonstrating the switching window in an SOA. EDFA: Erbium doped fiber amplifier. ...
... Figure 2.2: Calculated input and output pulse shape from a typical SOA................. 19 Figure 2.3: Schematic of an optical switch using XPM in an SOA........................... 20 Figure 2.4: Experimental setup for demonstrating the switching window in an SOA. EDFA: Erbium doped fiber amplifier. ...
Avalanche Ruggedness of Local Charge Balance Power Super Junction Transistors
... in terms of efficiency, compactness, weight and losses. Indeed, active pulse width modulation (PWM) rectifiers (see Fig.1.1) with minimized total harmonic distortion of the input current and high power factor have to be designed for future electric power control. Advanced architectures for three-pha ...
... in terms of efficiency, compactness, weight and losses. Indeed, active pulse width modulation (PWM) rectifiers (see Fig.1.1) with minimized total harmonic distortion of the input current and high power factor have to be designed for future electric power control. Advanced architectures for three-pha ...
Impact of Gate-Length Biasing on Threshold-Voltage Selection
... Triple-Vth can reduce leakage by ~8% more than is possible with dual-Vth Dual-Vth combined with biasing can achieve almost the same reduction ...
... Triple-Vth can reduce leakage by ~8% more than is possible with dual-Vth Dual-Vth combined with biasing can achieve almost the same reduction ...
3: Nodal Analysis
... The aim of nodal analysis is to determine the voltage at each node relative to the reference node (or ground). Once you have done this you can easily work out anything else you need. There are two ways to do this: (1) Nodal Analysis - systematic; always works (2) Circuit Manipulation - ad hoc; but c ...
... The aim of nodal analysis is to determine the voltage at each node relative to the reference node (or ground). Once you have done this you can easily work out anything else you need. There are two ways to do this: (1) Nodal Analysis - systematic; always works (2) Circuit Manipulation - ad hoc; but c ...
Power Status and Monitoring System
... functionality. These firmware upgrades shall be done through either the front or rear communication connection. No power monitor disassembly or changing of integrated circuit chips shall be required. 14. The following instantaneous readings, as well as their minimum and maximum readings since last r ...
... functionality. These firmware upgrades shall be done through either the front or rear communication connection. No power monitor disassembly or changing of integrated circuit chips shall be required. 14. The following instantaneous readings, as well as their minimum and maximum readings since last r ...
Sure Cross DXM100-Bx Wireless Controller Instruction Manual
... 4.4 Modbus Registers - Internal Local Registers (Modbus Slave 199) ...
... 4.4 Modbus Registers - Internal Local Registers (Modbus Slave 199) ...
ECSS-E-ST-20-20C
... The present standard applies to power distribution by LCLs/RLCLs for power systems, and in general for satellites, required to be Single Point Failure Free. The present standard document applies exclusively to the main bus power distribution by LCLs/RLCLs to external satellite loads. A particular ca ...
... The present standard applies to power distribution by LCLs/RLCLs for power systems, and in general for satellites, required to be Single Point Failure Free. The present standard document applies exclusively to the main bus power distribution by LCLs/RLCLs to external satellite loads. A particular ca ...
MOS Logic and Gate Circuits
... Therefore M2 will be in saturation which result the reduction of switching time ...
... Therefore M2 will be in saturation which result the reduction of switching time ...
DRAFT PURCHASE MANUAL
... The Materials/equipment supplied under this Contract will conform to the Standards mentioned in the Technical specifications, and, when no applicable standard is mentioned, the authoritative standards appropriate to the Materials / equipment’ i.e., BIS, such standards will be the latest. All materia ...
... The Materials/equipment supplied under this Contract will conform to the Standards mentioned in the Technical specifications, and, when no applicable standard is mentioned, the authoritative standards appropriate to the Materials / equipment’ i.e., BIS, such standards will be the latest. All materia ...
IQS 23 Family
... copper is not available in Zone 1, transients will flow via grounded copper of Zone 2. If Zone 2 has inadequate grounded copper, transients will couple in Zone 3 to/from the Ground Plane. Preferable for EFT/B currents to couple to/from Ground Plane in Zone 1 – highest immunity for ProxSense circuit. ...
... copper is not available in Zone 1, transients will flow via grounded copper of Zone 2. If Zone 2 has inadequate grounded copper, transients will couple in Zone 3 to/from the Ground Plane. Preferable for EFT/B currents to couple to/from Ground Plane in Zone 1 – highest immunity for ProxSense circuit. ...
Continuum Voltage Converter User`s Guide
... 3.5.Multi-tracking the CVC from a Sequencer It is possible to control the CVC via multiple Midi performances. In doing these types of Midi overdubs, it is quite conceivable to overload the Midi capabilities of the external DAW sequencer, as the DAW may have problems merging multiple Continuum origin ...
... 3.5.Multi-tracking the CVC from a Sequencer It is possible to control the CVC via multiple Midi performances. In doing these types of Midi overdubs, it is quite conceivable to overload the Midi capabilities of the external DAW sequencer, as the DAW may have problems merging multiple Continuum origin ...
4017, 4022
... positive edge of the clock signal when the clock enable signal is in the logical “0” state. The configuration of the CD4017BC and CD4022BC permits medium speed operation and assures a hazard free counting sequence. The 10/8 decoded outputs are normally in the logical “0” state and go to the logical ...
... positive edge of the clock signal when the clock enable signal is in the logical “0” state. The configuration of the CD4017BC and CD4022BC permits medium speed operation and assures a hazard free counting sequence. The 10/8 decoded outputs are normally in the logical “0” state and go to the logical ...
CCTV Balun Application Guide
... next to radar transmitters or very high voltage power lines, shielded twisted pair cable (STP) may help to eliminate severe noise problems. If STP is used, please ensure that shield is properly grounded at least on one end. If STP is not grounded, it may act as an antenna and induce additional noise ...
... next to radar transmitters or very high voltage power lines, shielded twisted pair cable (STP) may help to eliminate severe noise problems. If STP is used, please ensure that shield is properly grounded at least on one end. If STP is not grounded, it may act as an antenna and induce additional noise ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.