• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
IL410, IL4108
IL410, IL4108

... by a photocurrent source that permits the FET to conduct the main voltage to gate on the N-channel FET. Once the main voltage can enable the N-channel, it clamps the base of the phototransistor, disabling the first stage SCR predriver. The 600 V, 800 V blocking voltage permits control of off-line vo ...
DIGITAL ELECTRONICS: LOGIC AND CLOCKS
DIGITAL ELECTRONICS: LOGIC AND CLOCKS

... The flow of digital signals is controlled by transistors in various configurations depending on the logic family (see H&H 8.09 for details). For most purposes, we can imagine that the logic gates are composed of several ideal switches with just two states: OPEN and CLOSED. The state of a switch is c ...
ADA4922-1 数据手册DataSheet 下载
ADA4922-1 数据手册DataSheet 下载

... package due to the load drive for all outputs. The quiescent power is the voltage between the supply pins (VS) times the quiescent current (IS). The power dissipated due to the load drive depends upon the particular application. For each output, the power due to load drive is calculated by multiplyi ...
18-A 3.3-V Input Nonisolated Wide-Output Adjust SIP Module (Rev. A)
18-A 3.3-V Input Nonisolated Wide-Output Adjust SIP Module (Rev. A)

... The PTV03020W is a ready-to-use nonisolated power module, and part of a new class of complete dc/dc switching regulators from Texas Instruments. These regulators combine high performance with double-sided, surface-mount construction, to give designers the flexibility to power the most complex multip ...
Activity 1.2.3 Electrical Circuits – Simulation
Activity 1.2.3 Electrical Circuits – Simulation

... Since the late 1800s, engineers have designed systems to utilize electrical energy due to its ability to be converted, stored, transmitted, and reconverted efficiently into other forms of energy. In the 21st century, electrical energy production, distribution, and application have become consumer dr ...
International Electrical Engineering Journal (IEEJ) Vol. 5 (2014) No.10, pp. 1586-1593
International Electrical Engineering Journal (IEEJ) Vol. 5 (2014) No.10, pp. 1586-1593

... Restorer) and UPQC (Unified Power Quality Conditioner) [2]. The DSTATCOM is a shunt-active power filter connected in distribution system. It injects harmonic and reactive component of load current such that the unbalanced, harmonic, and reactive loads are converted into balanced linear resistive loa ...
T. Elsarnagawy, mde 207, semester 311, rcc
T. Elsarnagawy, mde 207, semester 311, rcc

... d. there is not enough information to say ...
Glossary
Glossary

... generated (often by burning coal) ...
Electrical Insulation in Power Apparatus and Systems - Web
Electrical Insulation in Power Apparatus and Systems - Web

EE121Lec02 - My FIT (my.fit.edu)
EE121Lec02 - My FIT (my.fit.edu)

Experiment 1 - RPI ECSE - Rensselaer Polytechnic Institute
Experiment 1 - RPI ECSE - Rensselaer Polytechnic Institute

... people and 80,000 square miles (207,000 km2) were left without electricity for up to 13 hours. The cause of the failure was human error that happened days before the blackout. Maintenance personnel incorrectly set a protective relay on one of the transmission lines from a Niagara generating station ...
experiment 1
experiment 1

... Three phase - 400 V (line to line): In his system we have three wires, one for each phase or line. In case the fourth wire is there it is neutral. While voltage between two phases/lines is 400 V, between any phase/line and neutral it is 230 V. ...
ZETA Converter based charge controller for efficient use of solar
ZETA Converter based charge controller for efficient use of solar

... One of the primary As solar energy is sustainable and available source of energy so it has become the main power source in current situation. It is free, clean and long-lasting. This energy system is one of the best choice for power production because of its low maintenance and operational cost. To ...
124-02_Oscilloscope_Lab
124-02_Oscilloscope_Lab

... the VOLTS/DIV set at 0.5 V and the TIME/DIV set at 0.5 s and record these settings into your lab book. When a new sweep starts push the tap key down ~5 times in succession, at about once per second. You have generated a “square wave” voltage. Once the “square wave” has been generated on your screen, ...
MAX5188/MAX5191 Dual, 8-Bit, 40MHz, Current/Voltage, Alternate-Phase Output DACs General Description
MAX5188/MAX5191 Dual, 8-Bit, 40MHz, Current/Voltage, Alternate-Phase Output DACs General Description

... The MAX5188/MAX5191 also employ a control amplifier, designed to simultaneously regulate the full-scale output current IFS for both MAX5188/MAX5191 outputs. The output current is calculated as follows: IFS = 8 ✕ IREF where I REF is the reference output current (I REF = VREFO / RSET) and IFS is the f ...
“static dV/dt”?
“static dV/dt”?

... Static dV/dt turn-on is non-destructive when series impedance limits the surge current. The triac turns off after a half cycle of conduction. The symbol for static dV/dt is dV/dtcr or dV/dt(s). Unit is KV/μs. 2. What are “commutating dV/dt” and “commutating di/dt”? The commutating dV/dt and commutat ...
ppt - Galileo - University of Virginia
ppt - Galileo - University of Virginia

Class 6 Slides
Class 6 Slides

...  We can replace the two series resistors with 1 single resistor, we call Req  The value of Req is the SUM of R1 & R2: Req=R1+R2=.5 Ω + .5 Ω = 1Ω ...
EN 2451419
EN 2451419

... differential subtractor stage provides the quantization error, which is then amplified (×16) by the gain stages. The two SHAs allow both the stages to concurrently process different signal samples, thus enabling high throughput, albeit at an initial two-clock-cycle latency. This latency however is o ...
Zener Diodes
Zener Diodes

SCAN92LV090 9 Channel Bus LVDS Transceiver w/ Boundary SCAN General Description
SCAN92LV090 9 Channel Bus LVDS Transceiver w/ Boundary SCAN General Description

... differential line drivers and nine receivers. To minimize bus loading, the driver outputs and receiver inputs are internally connected. The separate I/O of the logic side allows for loop back support. The device also features a flow through pin out which allows easy PCB routing for short stubs betwe ...
Interconnection Request and Generating Facility
Interconnection Request and Generating Facility

... rectifiers. The regulator power source is independent of the generator terminal voltage and current (not bus-fed). (5) Rotating AC Alternator Exciter with controlled (thyristor) rectifiers. The regulator power source is fed from the exciter output voltage. (6) Rotating AC Alternator Exciter with con ...
HMC-APH634 - Micross Components
HMC-APH634 - Micross Components

... The chip is back-metallized and can be die mounted with AuSn eutectic preforms or with electrically conductive epoxy. The mounting surface should be clean and flat. Eutectic Die Attach: A 80/20 gold tin preform is recommended with a work surface temperature of 255 °C and a tool temperature of 265 °C ...
AD7545A: CMOS 12-Bit Buffered Multiplying DAC Data Sheet (Rev C, 03/2000)
AD7545A: CMOS 12-Bit Buffered Multiplying DAC Data Sheet (Rev C, 03/2000)

... ringing when using high speed op amps. Note that all the circuits of Figures 4, 5 and 6 have constant input impedance at the VREF terminal. The circuit of Figure 4 can either be used as a fixed reference D/A converter so that it provides an analog output voltage in the range 0 to –VIN (note the inve ...
DAC-HF - DATEL
DAC-HF - DATEL

< 1 ... 1672 1673 1674 1675 1676 1677 1678 1679 1680 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report