MAX5091 28V, 100mA, Low-Quiescent-Current LDO with Reset and Power-Fail Input/Output General Description
... The MAX5091 high-voltage, LDO regulator operates from +5V to +28V input voltage. The device withstands up to 40V transients, providing protection against temporary overvoltage conditions like load dump. The MAX5091 incorporates internal feedback resistors for factory-preset voltages of either +5V (M ...
... The MAX5091 high-voltage, LDO regulator operates from +5V to +28V input voltage. The device withstands up to 40V transients, providing protection against temporary overvoltage conditions like load dump. The MAX5091 incorporates internal feedback resistors for factory-preset voltages of either +5V (M ...
TL783 数据资料 dataSheet 下载
... recommended whenever the regulator is located more than four inches from the power-supply filter capacitor. A 1-µF tantalum or aluminum electrolytic capacitor usually is sufficient. Adjustment-terminal capacitors are not recommended for use on the TL783 because they can seriously degrade load transi ...
... recommended whenever the regulator is located more than four inches from the power-supply filter capacitor. A 1-µF tantalum or aluminum electrolytic capacitor usually is sufficient. Adjustment-terminal capacitors are not recommended for use on the TL783 because they can seriously degrade load transi ...
AP2552-53(A) - Diodes Incorporated
... For AP2552A/53A, when an overcurrent condition is detected, the devices will limit the current until the overload condition is removed or the internal deglitch time (7-ms typical) is reached, and AP2552A/53A will be turned off. AP2552A/53A will remain latched off until power is cycled or the device ...
... For AP2552A/53A, when an overcurrent condition is detected, the devices will limit the current until the overload condition is removed or the internal deglitch time (7-ms typical) is reached, and AP2552A/53A will be turned off. AP2552A/53A will remain latched off until power is cycled or the device ...
doc - STAO
... 15) a) On the following three sets of diagrams, show where the Ammeters wired in the Circuit Picture, are on the Schematic Diagram b) Assume power supply produces 6 amperes and 12 volts, write the expected readings beside the each ...
... 15) a) On the following three sets of diagrams, show where the Ammeters wired in the Circuit Picture, are on the Schematic Diagram b) Assume power supply produces 6 amperes and 12 volts, write the expected readings beside the each ...
Basic BJT Amplifier
... RC Rib Vs RC Av r 1 RE Remember: Assume VA is infinite, ro is neglected ...
... RC Rib Vs RC Av r 1 RE Remember: Assume VA is infinite, ro is neglected ...
Minimization Of Total Harmonic Distortion Using Pulse Width
... Abstract: Multilevel inversion is a power conversion strategy used to synthesize a desired AC voltage from several levels of DC voltages with reduced total harmonic distortion. These multilevel inverters are used to increase inverter operating voltage, to minimize total harmonic distortion and to re ...
... Abstract: Multilevel inversion is a power conversion strategy used to synthesize a desired AC voltage from several levels of DC voltages with reduced total harmonic distortion. These multilevel inverters are used to increase inverter operating voltage, to minimize total harmonic distortion and to re ...
LVPECL terminations - A circuit approach
... 3. The PI and T networks have better control of the emitter currents through common mode current feedback. Using as example the T network with RTT = 50 ohms and VCCO = 3.3V, the common mode feedback from VCCO to the VTT node is 66% (actually somewhat less due to the different operating points of the ...
... 3. The PI and T networks have better control of the emitter currents through common mode current feedback. Using as example the T network with RTT = 50 ohms and VCCO = 3.3V, the common mode feedback from VCCO to the VTT node is 66% (actually somewhat less due to the different operating points of the ...
ADN4665 数据手册DataSheet 下载
... Channel 3 Noninverting Output Current Driver. When DIN3 is high, current flows out of DOUT3+. When DIN3 is low, current flows into DOUT3+. Channel 3 Inverting Output Current Driver. When DIN3 is high, current flows into DOUT3−. When DIN3 is low, current flows out of DOUT3−. Active Low Enable and Pow ...
... Channel 3 Noninverting Output Current Driver. When DIN3 is high, current flows out of DOUT3+. When DIN3 is low, current flows into DOUT3+. Channel 3 Inverting Output Current Driver. When DIN3 is high, current flows into DOUT3−. When DIN3 is low, current flows out of DOUT3−. Active Low Enable and Pow ...
AB66 Wien Bridge Oscillator Operating Manual Ver.1.1 An ISO 9001
... perhaps a trigger. They generally use some form of active device, lamp, or crystal, surrounded by passive devices such as resistors, capacitors, and inductors, to generate the output. There are two main classes of oscillator: Relaxation and Sinusoidal. Relaxation oscillators generate the triangular, ...
... perhaps a trigger. They generally use some form of active device, lamp, or crystal, surrounded by passive devices such as resistors, capacitors, and inductors, to generate the output. There are two main classes of oscillator: Relaxation and Sinusoidal. Relaxation oscillators generate the triangular, ...
User’s Manual 701931 Current Probe
... • To avoid short circuits and accidents that could result in injury or death, use the probe only with power lines carrying 600 V or less (CATII) or 300 V or less (CATIII). • You must connect the protective grounding before fastening the clamp to the object under measurement. • If you need to touch t ...
... • To avoid short circuits and accidents that could result in injury or death, use the probe only with power lines carrying 600 V or less (CATII) or 300 V or less (CATIII). • You must connect the protective grounding before fastening the clamp to the object under measurement. • If you need to touch t ...
MTY25N60E Power MOSFET 25 Amps, 600 Volts
... Resistance−General Data and Its Use.” Switching between the off−state and the on−state may traverse any load line provided neither rated peak current (IDM) nor rated voltage (VDSS) is exceeded and the transition time (tr,tf) do not exceed 10 µs. In addition the total power averaged over a complete s ...
... Resistance−General Data and Its Use.” Switching between the off−state and the on−state may traverse any load line provided neither rated peak current (IDM) nor rated voltage (VDSS) is exceeded and the transition time (tr,tf) do not exceed 10 µs. In addition the total power averaged over a complete s ...
key
... 2. Rank according to ammeter reading (current) from largest to smallest. All the light bulbs are identical and can be treated as ohmic resistors. Assume the ammeter has zero resistance, the batteries are ideal and the wires have zero resistance. Justify your reasoning. ...
... 2. Rank according to ammeter reading (current) from largest to smallest. All the light bulbs are identical and can be treated as ohmic resistors. Assume the ammeter has zero resistance, the batteries are ideal and the wires have zero resistance. Justify your reasoning. ...
Voltage Collapse and Sympathy Trips 2014 OTS
... turn, result in changes in the generator output. There will be an interaction between the system and rotor speed. • The term “equal area criteria” is used to describe the comparison of the area that represents the energy stored in the turbine generator during the acceleration period and the area tha ...
... turn, result in changes in the generator output. There will be an interaction between the system and rotor speed. • The term “equal area criteria” is used to describe the comparison of the area that represents the energy stored in the turbine generator during the acceleration period and the area tha ...
LTM8022 - 1A, 36V DC/DC uModule
... Block Diagram is shown above. The LTM8022 contains a current mode controller, power switching element, power inductor, power Schottky diode and a modest amount of input and output capacitance. The LTM8022 is a fixed frequency PWM regulator. The switching frequency is set by simply connecting the appr ...
... Block Diagram is shown above. The LTM8022 contains a current mode controller, power switching element, power inductor, power Schottky diode and a modest amount of input and output capacitance. The LTM8022 is a fixed frequency PWM regulator. The switching frequency is set by simply connecting the appr ...
R 2
... • In deriving the formula for the equivalent resistance of 2 resistors in parallel, we applied Kirchhoff's Second Rule (the junction rule). "At any junction point in a circuit where the current can divide (also called a node), the sum of the currents into the node must equal the sum of the currents ...
... • In deriving the formula for the equivalent resistance of 2 resistors in parallel, we applied Kirchhoff's Second Rule (the junction rule). "At any junction point in a circuit where the current can divide (also called a node), the sum of the currents into the node must equal the sum of the currents ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.