• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Abdullah H. Al-Badi*, Samy M. Ghania**, Ali H. Kasem***, and
Abdullah H. Al-Badi*, Samy M. Ghania**, Ali H. Kasem***, and

... soil resistivity, load current magnitude, configuration of the power lines, pipeline coating and mitigation system used). The effects of these factors are discussed in [9]; some factors such as the fault current level, separation distance and soil resistivity are found to exhibit a large influence o ...
Voltage Detection and Indication by Electric Field Measurement
Voltage Detection and Indication by Electric Field Measurement

Basic Circuitry and Measurements Lab 3 1
Basic Circuitry and Measurements Lab 3 1

Commercial Powersines COMEC
Commercial Powersines COMEC

Features •
Features •

... power amplifier, is integrated. The slope of the ramp signal is controlled internally so that spurious requirements are fulfilled. ...
High-Slew-Rate Single-Supply Operational Amplifier
High-Slew-Rate Single-Supply Operational Amplifier

ADG752 数据手册DataSheet下载
ADG752 数据手册DataSheet下载

... The ADG752 is designed on a submicron process that provides low power dissipation yet gives high switching speed and low on resistance. This part is a fully bidirectional switch and can handle signals up to and including the supply rails. Break-before-make switching action ensures the input signals ...
V04801146153
V04801146153

BU4069UB
BU4069UB

... damaging the IC. Avoid nearby pins being shorted to each other especially to ground, power supply and output pin. Inter-pin shorts could be due to many reasons such as metal particles, water droplets (in very humid environment) and unintentional solder bridge deposited in between pins during assembl ...
Introduction - Worcester Polytechnic Institute
Introduction - Worcester Polytechnic Institute

... photovoltaic cells are certainly nothing new, their use has become more common, practical, and useful for people worldwide. The most important aspect of a solar cell is that it generates solar energy directly to electrical energy through the solar photovoltaic module, made up of silicon cells. Altho ...
Determining the mechanical losses in a high
Determining the mechanical losses in a high

... – isolation of the power circuit from the computer; – determination of the actual rotational speed from the signals of the rotor position sensors; – transferring the determined speed to the computer. Isolation between the measuring system and the power circuit is achieved by using of the digital iso ...
MAX1473EVKIT.pdf
MAX1473EVKIT.pdf

... can have a dramatic effect on the effective inductance. For example, a 0.5in trace connecting a 100nH inductor adds an extra 10nH of inductance or 10%. To reduce the parasitic inductance, use wider traces and a solid ground or power plane below the signal traces. Also, use low-inductance connections ...
LTC2920-1/LTC2920-2 - Single/Dual Power Supply Margining
LTC2920-1/LTC2920-2 - Single/Dual Power Supply Margining

Electricity - humbertofloresphysicalscience
Electricity - humbertofloresphysicalscience

Installation Manual
Installation Manual

Amplifier Terms Defined (AN-60-038)
Amplifier Terms Defined (AN-60-038)

Putting Safety into Li-ion Battery Packs
Putting Safety into Li-ion Battery Packs

... discharge over current (DOC) and charge over current (COC). Each comparator feeds into a delay allowing the current to be greater than the limit for a period of time before action is taken. Loads are less controlled than chargers and fast action current discharge detection is needed to shut off the ...
Frequency Generator
Frequency Generator

... The board in Eurocard format hosts two independent generators with power amplifiers and a transformer for dc-decoupling. Its frequencies are stored in an internal EPROM and may be selected using either the 16 position HEX switch or an external controller (i.e. PLC). The generator has minimal power d ...
Maximum Peak Power Tracker - Worcester Polytechnic Institute
Maximum Peak Power Tracker - Worcester Polytechnic Institute

... photovoltaic cells are certainly nothing new, their use has become more common, practical, and useful for people worldwide. The most important aspect of a solar cell is that it generates solar energy directly to electrical energy through the solar photovoltaic module, made up of silicon cells. Altho ...
HT3213861389
HT3213861389

... a charge pump circuit to get a constant current at the output. The charge pump output is passed through a low pass filter to generate the control voltage for the VCO circuit. Hence there are four functional blocks in a DPLL circuit such as phase frequency detector (PFD), charge pump, low pass filter ...
owners manual ma2150
owners manual ma2150

... The main power cable should run from the amplifier location, through or under the vehicle, to the battery. You must use a grommet wherever the cable passes through a steel panel to prevent an eventual short to ground. The ground connection is the most important part of any installation. If the conne ...
LTC5540 - 0.6GHz to 1.3GHz High Dynamic Range Downconverting Mixer.
LTC5540 - 0.6GHz to 1.3GHz High Dynamic Range Downconverting Mixer.

... to 4GHz frequency range. The LTC5540 is optimized for 0.6GHz to 1.3GHz RF applications. The LO frequency must fall within the 0.7GHz to 1.2GHz range for optimum performance. A typical application is a LTE or GSM receiver with a 700MHz to 915MHz RF input and high-side LO. The LTC5540 is designed for ...
ILVS-30 Series - Innovative Power Products, Inc.
ILVS-30 Series - Innovative Power Products, Inc.

... Innovative Power Product’s three-conductor low voltage splice kits, ILVS-30 series kits are heatshrinkable splice kits for splicing three-conductor plastic or rubber insulated unarmored power cables. The ILVS-30 kits cover a conductor range from 8 AWG-1000 kcmil for power cables rated up to 1000 vol ...
900MB Series
900MB Series

... buffered inputs are active-low. These models are the complement of the 904, 905, and 906 units which have open-source, high-side output switches and active-high inputs. Socketed pull-up resistors are easily removed or exchanged to satisfy your application requirements. The 903MB model has twelve inp ...
3: Electrical Measurements Review
3: Electrical Measurements Review

< 1 ... 1405 1406 1407 1408 1409 1410 1411 1412 1413 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report