node, series, parallel
... 3) Identify if the nodes are ordinary (red) or extraordinary (blue,yellow,green,etc.): If a node connects only TWO elements, it is ordinary. These nodes are red in the examples above. If a node connect ...
... 3) Identify if the nodes are ordinary (red) or extraordinary (blue,yellow,green,etc.): If a node connects only TWO elements, it is ordinary. These nodes are red in the examples above. If a node connect ...
distributed mppt based cascaded h-bridge multilevel inverter
... has been used to find the phase angle of the grid voltage. As a classic control scheme in three-phase systems, the grid currents in abc coordinates are converted to dq coordinates and regulated through proportional-integral (PI) coordinates, which is then converted back to three phases. The distribu ...
... has been used to find the phase angle of the grid voltage. As a classic control scheme in three-phase systems, the grid currents in abc coordinates are converted to dq coordinates and regulated through proportional-integral (PI) coordinates, which is then converted back to three phases. The distribu ...
Micro Family
... DC input range: 250 – 425 V Isolated output Input surge withstand: 500 V for 100 ms DC output: 2 – 48 V Programmable output: 10 to 110% Regulation: ±0.5% no load to full load Efficiency: Up to 88% Maximum operating temp: 100°C, full load Power density: up to 90 W per cubic inch Height above board: 0 ...
... DC input range: 250 – 425 V Isolated output Input surge withstand: 500 V for 100 ms DC output: 2 – 48 V Programmable output: 10 to 110% Regulation: ±0.5% no load to full load Efficiency: Up to 88% Maximum operating temp: 100°C, full load Power density: up to 90 W per cubic inch Height above board: 0 ...
Table 3.1 Table 3.2
... to be familiar with real high voltages which are used in electrical energy systems. Practical experience of high voltage measurements, different types of electrical discharge generation, real high voltage circuit engineering is very useful for future practical engineering activity. All workshops are ...
... to be familiar with real high voltages which are used in electrical energy systems. Practical experience of high voltage measurements, different types of electrical discharge generation, real high voltage circuit engineering is very useful for future practical engineering activity. All workshops are ...
chapter 5
... Rotating machines are normally divided into categories: those with voltage rating less than 6600 V are called low voltage machines, and the others are high voltage machines. Because of the difficulty of insulating high voltages, machines above 22 kV rating are not built except under special conditio ...
... Rotating machines are normally divided into categories: those with voltage rating less than 6600 V are called low voltage machines, and the others are high voltage machines. Because of the difficulty of insulating high voltages, machines above 22 kV rating are not built except under special conditio ...
ACD-50NAV, ACD-51NAV, ACDC-52NAV, ACD
... measurements on primary overcurrent protection devices and ripple control units. Measurement Category III (CAT III) is for measurements performed in the building installation. Examples are measurements on distribution boards, circuit- breakers, wiring, including cables, bus-bars, junction boxes, swi ...
... measurements on primary overcurrent protection devices and ripple control units. Measurement Category III (CAT III) is for measurements performed in the building installation. Examples are measurements on distribution boards, circuit- breakers, wiring, including cables, bus-bars, junction boxes, swi ...
Induced AC creates problems for pipelines in utility corridors
... be 0.1mA, resulting in a blocking voltage of two volts. In comparison to a polarization cell, the leakage current of a polarization cell is about 50 A at 2 V. To reduce the leakage current to 0.1mA across a polarization cell would require a maximum voltage of only 0.15 V across the cell. Corrosion. ...
... be 0.1mA, resulting in a blocking voltage of two volts. In comparison to a polarization cell, the leakage current of a polarization cell is about 50 A at 2 V. To reduce the leakage current to 0.1mA across a polarization cell would require a maximum voltage of only 0.15 V across the cell. Corrosion. ...
SGB-6433(Z) 数据资料DataSheet下载
... Caution! ESD sensitive device. Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional op ...
... Caution! ESD sensitive device. Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional op ...
GPON OLT Optical Transceiver SFP Module RTXM167-522
... The GPON OLT Transceiver is designed for Gigabit-capable Passive Optical Network(GPON)transmission. The module incorporates 1490nm DFB continuous-mode transmitter and 1310nm burst-mode APD receiver. The transmitter section uses a high efficiency 1490nm DFB laser and an integrated laser driver which ...
... The GPON OLT Transceiver is designed for Gigabit-capable Passive Optical Network(GPON)transmission. The module incorporates 1490nm DFB continuous-mode transmitter and 1310nm burst-mode APD receiver. The transmitter section uses a high efficiency 1490nm DFB laser and an integrated laser driver which ...
How to achieve consistency with AD
... Using power planes allows components to be connected to the appropriate voltage easily i.e. no surface track required just a short connection through a via. As there are likely to be occasions where more than one voltage level is required, then several power planes may be necessary or a single plane ...
... Using power planes allows components to be connected to the appropriate voltage easily i.e. no surface track required just a short connection through a via. As there are likely to be occasions where more than one voltage level is required, then several power planes may be necessary or a single plane ...
LMH2191 Dual Channel 52 MHz Clock Tree Driver (Rev. D)
... that enables low phase noise on the clock outputs, and low quiescent current for portable applications. It can also be used to supply the TCXO. The following sections provide a detailed description of each block. ...
... that enables low phase noise on the clock outputs, and low quiescent current for portable applications. It can also be used to supply the TCXO. The following sections provide a detailed description of each block. ...
objective - Technicalsymposium
... Conductor system. Which system is better and why? 1.2 A single circuit three phase transposed transmission line is composed of four ACSR 1,272,000 cmil conductors per phase with flat horizontal spacing of 14 m between Phases a and b and between phases b and c. The bundle spacing is 45 cm. The Conduc ...
... Conductor system. Which system is better and why? 1.2 A single circuit three phase transposed transmission line is composed of four ACSR 1,272,000 cmil conductors per phase with flat horizontal spacing of 14 m between Phases a and b and between phases b and c. The bundle spacing is 45 cm. The Conduc ...
MOBILE CONTROLLED HOME APPLIANCES
... the output of this IC (Pin 5) sets to high and further clock pulse reset back the IC. (The outputs toggle whenever a key is pressed). When we press and release any of the keys among 1, 3, 5, 7, 9 and * keys, the DTMF decoder IC generates a high pulse which acts as a clock to our flip flop and sets ...
... the output of this IC (Pin 5) sets to high and further clock pulse reset back the IC. (The outputs toggle whenever a key is pressed). When we press and release any of the keys among 1, 3, 5, 7, 9 and * keys, the DTMF decoder IC generates a high pulse which acts as a clock to our flip flop and sets ...
TS3005 - Silicon Labs
... period is approximately 715.88 minutes with a 50% duty cycle. As design aids, Tables 2 lists TS3004’s typical FOUT period for various standard values for RSET and FDIV2:0 = 111(7). The output period can be user-adjusted from 1.7ms to 33hrs without additional components. Frequency divider inputs FDIV ...
... period is approximately 715.88 minutes with a 50% duty cycle. As design aids, Tables 2 lists TS3004’s typical FOUT period for various standard values for RSET and FDIV2:0 = 111(7). The output period can be user-adjusted from 1.7ms to 33hrs without additional components. Frequency divider inputs FDIV ...
Capacitors for Power Factor Correction
... statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check ...
... statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check ...
The Diode Exercise in Excel
... Expected completion time: 1 hour to 2 hours. The first time may take 2 hours. The advantage to using Excel is that once you have the file set up you can just copy it to make following exercises. The exercise 1) Select a diode to do the exercise with. 2) Select a resistor within the safe limits of th ...
... Expected completion time: 1 hour to 2 hours. The first time may take 2 hours. The advantage to using Excel is that once you have the file set up you can just copy it to make following exercises. The exercise 1) Select a diode to do the exercise with. 2) Select a resistor within the safe limits of th ...
dual rectifier triode
... The three tube stages in the AX84 amplify the input signal. V2B amplifies the input, V2A amplifies this some more, and V1 boosts this even more - enough to drive the output transformer/speaker load. The gain of each stage can be determined mathematically. To do this, we need to understand tube param ...
... The three tube stages in the AX84 amplify the input signal. V2B amplifies the input, V2A amplifies this some more, and V1 boosts this even more - enough to drive the output transformer/speaker load. The gain of each stage can be determined mathematically. To do this, we need to understand tube param ...
DAC2904 数据资料 dataSheet 下载
... The data input ports of the DAC2904 accept a standard positive coding with data bit D13 being the most significant bit (MSB). The converter outputs support a clock rate of up to 125MSPS. The best performance will typically be achieved with a symmetric duty cycle for write and clock; however, the dut ...
... The data input ports of the DAC2904 accept a standard positive coding with data bit D13 being the most significant bit (MSB). The converter outputs support a clock rate of up to 125MSPS. The best performance will typically be achieved with a symmetric duty cycle for write and clock; however, the dut ...
UCC28521 数据资料 dataSheet 下载
... the UCC28521/28 is the trailing-edge / trailing-edge (TEM/TEM) modulation scheme for the PFC/PWM stages. The UCC28528 differs from the UCC28521 as its PWM stage does not turn off with the falling bulk voltage. The UCC28528 PWM was designed for low power auxiliary supplies. These devices offer perfor ...
... the UCC28521/28 is the trailing-edge / trailing-edge (TEM/TEM) modulation scheme for the PFC/PWM stages. The UCC28528 differs from the UCC28521 as its PWM stage does not turn off with the falling bulk voltage. The UCC28528 PWM was designed for low power auxiliary supplies. These devices offer perfor ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.