• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Nonlinear Dynamics of the RL-Varactor Circuit in the Depletion Region
Nonlinear Dynamics of the RL-Varactor Circuit in the Depletion Region

Typical HVAC System Design Instructions for Tucson Medical Center
Typical HVAC System Design Instructions for Tucson Medical Center

The Fundamentals of Three-Phase Power Measurements
The Fundamentals of Three-Phase Power Measurements

Linatron® - Mi™ Modular interlaced high-energy X
Linatron® - Mi™ Modular interlaced high-energy X

Installation Guide — GEPS24-100U
Installation Guide — GEPS24-100U

... • Limited to use in dry and damp locations. • The grounding and bonding of the LED Driver shall be done in accordance with National Electric Code (NEC) Article 600. • Follow all National Electric Codes (NEC) and local codes. • These products are only suitable for connection to a circuit fr ...
AN29 - Some Thoughts on DC-DC Converters
AN29 - Some Thoughts on DC-DC Converters

... counter output (Trace B) combines with the logic network to present alternately phased clock bursts (Traces  C and D) to the base resistors of Q1 and Q2. When φ1 (Trace B) is unclocked it resides in its high state, biasing Q2 and Q4 on. Q4’s collector effectively grounds the “bottom” of L1 (Trace H) ...
Student Handout #2 Extract - AS 440-221, Safe Laboratory
Student Handout #2 Extract - AS 440-221, Safe Laboratory

... passing through the skin could be calculated as 120 divided by 200,000 = 0.001 ampere (1 milliampere), which would not be particularly harmful. If, however, the resistance of the skin were reduced to 1,000 ohms because of perspiration, and if the person were standing on a wet or damp ground, the cur ...
TL082
TL082

... 8. Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Recommended Operating Conditions indicate conditions for which the device is intended to be functional, but specific performance is not guaranteed. For guaranteed specifications and the test conditions, see the ...
CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM
CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM

... Phase unbalance monitoring Applying control supply voltage begins the fixed start-up delay tS. When tS is complete and all phases are present with correct voltage and with correct phase sequence, the output relays energize and the yellow LED R/T glows. Type of tripping delay = ON-delay A If the volt ...
The George Washington University School of Engineering and
The George Washington University School of Engineering and

Lesson: 23
Lesson: 23

vlsi design of low power high speed adc
vlsi design of low power high speed adc

CS5305 Three−Phase Synchronous Switching Step−Down
CS5305 Three−Phase Synchronous Switching Step−Down

... low−voltage, high−current power needs of next−generation workstation and server processors. This IC provides high accuracy and the industry’s fastest transient response, reducing the need for large banks of output capacitors and providing the most compact, reliable, and economical power supply. Sinc ...
Comparison of Multi-Area Load Frequency Control by PI
Comparison of Multi-Area Load Frequency Control by PI

... al., 2004] has been proposed for AGC. For designing controllers based on these techniques, the perfect model is required which has to track the state variables and satisfy system constraints. Therefore it is difficult to apply these adaptive control techniques to AGC in practical implementations. In ...
MAGNE-SONIC 300 SERIES 4-20mA LEVEL TRANSMITTERS
MAGNE-SONIC 300 SERIES 4-20mA LEVEL TRANSMITTERS

... The milliamp meter reading should be less than 20 mA. If the reading is higher than 20 mA, the measuring element has produced a capacitance change greater than the maximum span of the instrument. This is unlikely, except in cases where the measuring element is very long and submerged in conductive m ...
Series-Parallel Circuits
Series-Parallel Circuits

... Circuit: A conducting path for current from one side of a source of voltage and current -- the positive side of a battery, for example -- to the other -- or the negative side of the same battery in the following example: i. To preface the example: When apply Ohm’s law you often must think of a large ...
A+ Guide to Managing and Maintaining your PC, 6e
A+ Guide to Managing and Maintaining your PC, 6e

Power Devices Loading in Multilevel Converters for 10 MW Wind
Power Devices Loading in Multilevel Converters for 10 MW Wind

... seen that, the loss distribution characteristics are quite different not only between configurations, but also between generator side and grid side converters. For the grid side converter, 3L-NPC BTB shows dramatically unequal loss distribution in power devices: the outer switches (S1 and S4) as wel ...
Agilent U1251B and U1252B Handheld Digital Multimeter Quick
Agilent U1251B and U1252B Handheld Digital Multimeter Quick

3. SWITCHED RELUCTANCE MOTORS 3.1
3. SWITCHED RELUCTANCE MOTORS 3.1

... region, torque generation is zero even when a current is present in this interval. In spite of this fact, it serves a useful function by providing time for the stator current to come to zero or lower levels when it is commutated, thus preventing negative torque generation for part of the time if the ...
2016 C.. - CS ManTech
2016 C.. - CS ManTech

... investigate the number of trap densities created in HMETs after off-state step-stressing [10,11]. Drain current subthreshold swing has been commonly used to estimate trap densities in metal oxide semiconductor field effect transistors and AlGaN/GaN HEMTs. The sub-threshold swing increased from ~98 t ...
ADG752 数据手册DataSheet下载
ADG752 数据手册DataSheet下载

... Figure 8 shows the T-switch configuration. While the switch is in the OFF state, the shunt switch is closed and the two series switches are open. The closed shunt switch provides a signal path to ground for any of the unwanted signals that find their way through the off capacitances of the series’ M ...
Efficient Control Scheme for Five-level (NPC) Shunt Active Power
Efficient Control Scheme for Five-level (NPC) Shunt Active Power

... as an ideal current source which can provide a dynamic and adjustable solution for eliminating the harmonic currents and compensating the reactive power by injection of compensation currents [2, 3]. The most powerful converter used has been the two-level voltage source inverter [4, 5]. However, due ...
Rectifier and Bond Reading
Rectifier and Bond Reading

... Resister Wire Application ...
PowerPoint
PowerPoint

< 1 ... 943 944 945 946 947 948 949 950 951 ... 1789 >

Buck converter



A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report