MV-7 Current Transformer
... »» Transformers are shipped with the short- circuiting link closed and the terminal cover in the reversed (short-circuited) position. When a meter is installed, the terminal cover is removed, the meter current coils are connected across the transformers secondary terminals, the short-circuiting link ...
... »» Transformers are shipped with the short- circuiting link closed and the terminal cover in the reversed (short-circuited) position. When a meter is installed, the terminal cover is removed, the meter current coils are connected across the transformers secondary terminals, the short-circuiting link ...
A New Strained-Silicon Channel Trench
... wafer and grow a 2.5-μm-thick N− Si epilayer (ND = 1 × 1016 cm−3 ). This layer forms the drift region of the device. Over this layer. we grow a 0.5-μm-thick N-type Si1−x Gex buffer layer (ND = 1 × 1019 cm−3 ) while gradually changing the x-composition from 0% to 20%. After this, a 0.4-μmthick P-type ...
... wafer and grow a 2.5-μm-thick N− Si epilayer (ND = 1 × 1016 cm−3 ). This layer forms the drift region of the device. Over this layer. we grow a 0.5-μm-thick N-type Si1−x Gex buffer layer (ND = 1 × 1019 cm−3 ) while gradually changing the x-composition from 0% to 20%. After this, a 0.4-μmthick P-type ...
Protection and control HV/MV substation Sepam
... Detects trip circuit faults (shunt-trip coil). The function can only be used if the Sepam and trip circuit auxiliary power sources have the same voltage rating. If the equipment contains an undervoltage release coil only, the trip circuit is not supervised since it is fail-safe. This function can al ...
... Detects trip circuit faults (shunt-trip coil). The function can only be used if the Sepam and trip circuit auxiliary power sources have the same voltage rating. If the equipment contains an undervoltage release coil only, the trip circuit is not supervised since it is fail-safe. This function can al ...
GTL2010 1. General description 10-bit bidirectional low voltage translator
... Bidirectional translation to multiple higher voltage levels such as an I2C-bus application ...
... Bidirectional translation to multiple higher voltage levels such as an I2C-bus application ...
P83123
... number of strobes; be sure to add the currents for any other appliances, including audible signaling appliances, powered by the same source and include any required safety factors. If the peak current exceeds the power supplies’ peak capacity, the output voltage provided by the power supplies may dr ...
... number of strobes; be sure to add the currents for any other appliances, including audible signaling appliances, powered by the same source and include any required safety factors. If the peak current exceeds the power supplies’ peak capacity, the output voltage provided by the power supplies may dr ...
BD9015KV-M
... COMP voltage will drop and recovery will be done with the minimum duty cycle, which may lead to undershoot of the output. In case this undershoot becomes an application problem, the output capacitor should be increased or the phase compensation RC constant should be adjusted. BD9016KV-M, If the outp ...
... COMP voltage will drop and recovery will be done with the minimum duty cycle, which may lead to undershoot of the output. In case this undershoot becomes an application problem, the output capacitor should be increased or the phase compensation RC constant should be adjusted. BD9016KV-M, If the outp ...
High output alternator with multi stage regulator
... Most batteries should not be charged at a rate exceeding 30% of their Ah capacity (example: 120 A max. charge current for 400 Ah battery bank). A high charge rate will reduce service life. If a high charge rate is nevertheless required, always apply temperature compensation, which will lower the cha ...
... Most batteries should not be charged at a rate exceeding 30% of their Ah capacity (example: 120 A max. charge current for 400 Ah battery bank). A high charge rate will reduce service life. If a high charge rate is nevertheless required, always apply temperature compensation, which will lower the cha ...
Triple Differential Driver With Output Pull-Down AD8133
... ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although this product features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to ...
... ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although this product features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to ...
An Oscillating Active CMOS Pixel for Subretinal Stimulation
... the conductance of T1 controls how fast the output S charges the conductance of T2 controls how fast the output S discharges the higher the conductance on either T1 or T2, the faster the circuit oscillates the ratio of the conductances on T1 and T2 determines the duty cycle of the output S ...
... the conductance of T1 controls how fast the output S charges the conductance of T2 controls how fast the output S discharges the higher the conductance on either T1 or T2, the faster the circuit oscillates the ratio of the conductances on T1 and T2 determines the duty cycle of the output S ...
High voltage pulse generators and spark gap for gaseous discharge
... it for cleaning. As the spark gap becomes dirty, shot-to-shot trigger jitter wil! start to increase. Typical lifetime of the sparking points is generally one mil!ion shots. Cleaning frequency depends on operation, but in any case, after long periods of disuse, the electrodes should be removed and cl ...
... it for cleaning. As the spark gap becomes dirty, shot-to-shot trigger jitter wil! start to increase. Typical lifetime of the sparking points is generally one mil!ion shots. Cleaning frequency depends on operation, but in any case, after long periods of disuse, the electrodes should be removed and cl ...
Rotary Phase Converter Data Sheet
... under load when the power comes back on. Equipping three phase loads with magnetic starters is recommended. A magnetic starter will automatically shut off equipment if power is lost, thus protecting the TEMCo Phase Converter from starting under load when power is restored. ...
... under load when the power comes back on. Equipping three phase loads with magnetic starters is recommended. A magnetic starter will automatically shut off equipment if power is lost, thus protecting the TEMCo Phase Converter from starting under load when power is restored. ...
2212 Contrec Avtrac DataSheet
... Two solid state relays are provided which can be set up to control a single or a two stage valve with slow stop and/or slow start. Alternatively, the second output can be used to control a pump. ...
... Two solid state relays are provided which can be set up to control a single or a two stage valve with slow stop and/or slow start. Alternatively, the second output can be used to control a pump. ...
LT6600-20
... resistance yet the network analyzer output is calibrated for a 50Ω load resistance. The 1:1 transformer, 53.6Ω and 388Ω resistors satisfy the two constraints above. The transformer converts the single-ended source into a differential stimulus. Similarly, the output of the LT6600-20 will have lower d ...
... resistance yet the network analyzer output is calibrated for a 50Ω load resistance. The 1:1 transformer, 53.6Ω and 388Ω resistors satisfy the two constraints above. The transformer converts the single-ended source into a differential stimulus. Similarly, the output of the LT6600-20 will have lower d ...
Buck converter
A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.