LHBF-48X - NPI electronic
... devices such as sensor inputs are equipped with very sensitive FET amplifiers, which can be damaged by electrostatic charge and must therefore be handled with care. This can be avoided by touching a grounded metal surface when changing or adjusting sensors. Always turn power off when adding or remov ...
... devices such as sensor inputs are equipped with very sensitive FET amplifiers, which can be damaged by electrostatic charge and must therefore be handled with care. This can be avoided by touching a grounded metal surface when changing or adjusting sensors. Always turn power off when adding or remov ...
11kV and 22kV padmount and indoor distribution transformer
... Product approval and audit form Endeavour use only: Product approval officer:……………………………… Date received:………………………… Application ID no:……………………………………… Approval no:…………………………… Manufacturer: ……………………………………………………….. Contact person and details: ………………………………………………………….. ...
... Product approval and audit form Endeavour use only: Product approval officer:……………………………… Date received:………………………… Application ID no:……………………………………… Approval no:…………………………… Manufacturer: ……………………………………………………….. Contact person and details: ………………………………………………………….. ...
AN-8017 FMS6151 Evaluation Board Application Note AN-8017 FMS6151 Ev
... output coupling capacitors. If the output is AC-coupled, the SAG correction circuit can be used to reduce the value and the physical size of the AC output coupling capacitors and still product acceptable field tilt. ...
... output coupling capacitors. If the output is AC-coupled, the SAG correction circuit can be used to reduce the value and the physical size of the AC output coupling capacitors and still product acceptable field tilt. ...
1. Introduction: To realize register file optimization with ViPro
... consideration, and knobs such as row & column number and bank size are used in estimating power consumption and delay of RF. Some other memory analyzing tools such as Cacti are only capable architecture level exploration, but they are not allowed to modify the bottom circuit level of memory. What's ...
... consideration, and knobs such as row & column number and bank size are used in estimating power consumption and delay of RF. Some other memory analyzing tools such as Cacti are only capable architecture level exploration, but they are not allowed to modify the bottom circuit level of memory. What's ...
New Push-Pull Tube Amplifiers
... result in new equidistant straight lines. The damping factor of the amplifier is in fact the slope of those lines. However, the lines may be equidistant when crossing the load line of the OPT’s primary, yet still have different slopes, indicating that the damping factor will change with the amount o ...
... result in new equidistant straight lines. The damping factor of the amplifier is in fact the slope of those lines. However, the lines may be equidistant when crossing the load line of the OPT’s primary, yet still have different slopes, indicating that the damping factor will change with the amount o ...
EMMI LAB Laboratory
... lumped parameters, the windings of transformers and chokes, and inductance coils. Their principle of operation depends on the method of measurement. The “voltmeter-ammeter” method (Figure 1) is used for measuring relatively large inductances (from 0.1 to 1,000 henrys [H]) when the resistance of the ...
... lumped parameters, the windings of transformers and chokes, and inductance coils. Their principle of operation depends on the method of measurement. The “voltmeter-ammeter” method (Figure 1) is used for measuring relatively large inductances (from 0.1 to 1,000 henrys [H]) when the resistance of the ...
Circuit Note - Analog Devices
... and can be set in increments of 250 Hz. Most resolvers are specified at a fixed excitation fequency, typically around 10 kHz. Different resolvers have difference phase shifts that must also be considered in the signal chain design. The excitation signal is applied to the resolver rotor winding which ...
... and can be set in increments of 250 Hz. Most resolvers are specified at a fixed excitation fequency, typically around 10 kHz. Different resolvers have difference phase shifts that must also be considered in the signal chain design. The excitation signal is applied to the resolver rotor winding which ...
Hand Dryer - JD MacDonald
... 4. a. For in-wall (concealed) power supply Provide supply wire to KO location according to local code and attach securely to chassis at KO with appropriate strain relief connector (not supplied). b. For Surface Mounted Conduit (exposed) power supply Provide appropriate conduit to entry location acco ...
... 4. a. For in-wall (concealed) power supply Provide supply wire to KO location according to local code and attach securely to chassis at KO with appropriate strain relief connector (not supplied). b. For Surface Mounted Conduit (exposed) power supply Provide appropriate conduit to entry location acco ...
AN-3004 - Fairchild
... Once triggered, the detector stays latched in the "on state" until the current flow through the detector drops below the holding current (IH) which is typically 100 µA. At this time, the detector reverts to the "off" (non-conducting) state. The detector may be triggered "on" not only by IFT but also ...
... Once triggered, the detector stays latched in the "on state" until the current flow through the detector drops below the holding current (IH) which is typically 100 µA. At this time, the detector reverts to the "off" (non-conducting) state. The detector may be triggered "on" not only by IFT but also ...
Download PDF
... Thermophotovoltaic (TPV) converters have attracted interest in the field of direct energy conversion due to the potential for relatively high efficiency operation with no moving parts. For hot side temperatures of less than 1500o C, greater than 20% thermal to electric efficiency requires: (i) Effic ...
... Thermophotovoltaic (TPV) converters have attracted interest in the field of direct energy conversion due to the potential for relatively high efficiency operation with no moving parts. For hot side temperatures of less than 1500o C, greater than 20% thermal to electric efficiency requires: (i) Effic ...
Motor control and sensor testing
... 1000? Note: the original cutoff frequency was somewhat lower than 160 Hz, possibly as low as 80 Hz, because the single-ended filter capacitors and the differential filter capacitor were erroneously both installed at the same time. Result: At a 160 Hz lowpass cutoff frequency, the noise levels from t ...
... 1000? Note: the original cutoff frequency was somewhat lower than 160 Hz, possibly as low as 80 Hz, because the single-ended filter capacitors and the differential filter capacitor were erroneously both installed at the same time. Result: At a 160 Hz lowpass cutoff frequency, the noise levels from t ...
EE 442
... what range of values the meter will read. Digital multimeters typically have a LCD or LED display and in many cases are auto-ranging. That is, the meter will automatically select the most appropriate range for making the measurement. In this lab either an analog or a digital meter can be used with l ...
... what range of values the meter will read. Digital multimeters typically have a LCD or LED display and in many cases are auto-ranging. That is, the meter will automatically select the most appropriate range for making the measurement. In this lab either an analog or a digital meter can be used with l ...
Variable Frequency Drives - a Comparison of VSI versus
... g. The motors for VSI drives are custom built with appropriate motor insulation systems. This usually means a higher voltage insulation system than for a standard utility-fed motor. LCI Drive Design a. The input transformer is separate from the LCI drive, so there are no limits on the input transfor ...
... g. The motors for VSI drives are custom built with appropriate motor insulation systems. This usually means a higher voltage insulation system than for a standard utility-fed motor. LCI Drive Design a. The input transformer is separate from the LCI drive, so there are no limits on the input transfor ...
Slide 1
... Objective of analysis: to find expression for vc(t) for t >0 , i.e. to get the voltage response of the circuit to a step change in voltage source OR simply to get a step response ...
... Objective of analysis: to find expression for vc(t) for t >0 , i.e. to get the voltage response of the circuit to a step change in voltage source OR simply to get a step response ...
MC14532B - 8-Bit Priority Encoder
... Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product performance may not be indicated by the Electrical Characteristics if operated under different conditions. 2. Data labelled “Typ” is not to be used for design ...
... Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product performance may not be indicated by the Electrical Characteristics if operated under different conditions. 2. Data labelled “Typ” is not to be used for design ...
Power Tool Safety Terms
... third grounding prong), and are equipped with a polarized two-prong plug (See “Polarized Plug”). Doubleinsulated tools will be marked with a “double square” ( ), or the words “Double-Insulated” on the tool’s rating plate. Ear Protection – Devices such as ear muffs or ear plugs that reduce the intens ...
... third grounding prong), and are equipped with a polarized two-prong plug (See “Polarized Plug”). Doubleinsulated tools will be marked with a “double square” ( ), or the words “Double-Insulated” on the tool’s rating plate. Ear Protection – Devices such as ear muffs or ear plugs that reduce the intens ...
Slide 1
... GTO devices makes forced commutation possible, and therefore PWM converters offer a more elegant solution ...
... GTO devices makes forced commutation possible, and therefore PWM converters offer a more elegant solution ...
FT7511 Reset Timer with Fixed Delay and Reset Pulse
... pulled HIGH prior to VCC ramp, the FT7511 enters Test Mode and the reset output, /RST1, is immediately pulled LOW for factory testing. The DSR pin MUST be forced to GND during normal operation. The DSR pin should never be driven HIGH or left to float during normal operation. The DSR pin state should ...
... pulled HIGH prior to VCC ramp, the FT7511 enters Test Mode and the reset output, /RST1, is immediately pulled LOW for factory testing. The DSR pin MUST be forced to GND during normal operation. The DSR pin should never be driven HIGH or left to float during normal operation. The DSR pin state should ...
Buck converter
A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.