Datasheet
... signals are often received from a transmission line where long cables and system interference can degrade signal quality, the inputs have enhanced sensitivity to detect weakened signals. The receivers also feature a typical hysteresis margin of 500mV for clean reception of slowly transitioning signa ...
... signals are often received from a transmission line where long cables and system interference can degrade signal quality, the inputs have enhanced sensitivity to detect weakened signals. The receivers also feature a typical hysteresis margin of 500mV for clean reception of slowly transitioning signa ...
M48Z02
... but does not jeopardize the rest of the RAM's content. At voltages below VPFD (min), the user can be assured the memory will be in a write protected state, provided the VCC fall time is not less than tF. The M48Z02/12 may respond to transient noise spikes on VCC that reach into the deselect window d ...
... but does not jeopardize the rest of the RAM's content. At voltages below VPFD (min), the user can be assured the memory will be in a write protected state, provided the VCC fall time is not less than tF. The M48Z02/12 may respond to transient noise spikes on VCC that reach into the deselect window d ...
AC Induction Motor Slip – What It Is And How To
... generate torque. In actual operation, rotor speed always lags the magnetic field's speed, allowing the rotor bars to cut magnetic lines of force and produce useful torque. This speed difference is called slip speed. Slip also increases with load and is necessary for torque production. Slip Depends O ...
... generate torque. In actual operation, rotor speed always lags the magnetic field's speed, allowing the rotor bars to cut magnetic lines of force and produce useful torque. This speed difference is called slip speed. Slip also increases with load and is necessary for torque production. Slip Depends O ...
ZRC500
... 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in ...
... 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in ...
- Granite River Labs
... VNA and Impedance Measurement • VNA is a sine-wave generator with a source impedance of 50 Ohms. • Measure reflected wave S11 to estimate impedance • When power impedance is less than 1 ohm, VNA can not provide accurate results with one port measurement ...
... VNA and Impedance Measurement • VNA is a sine-wave generator with a source impedance of 50 Ohms. • Measure reflected wave S11 to estimate impedance • When power impedance is less than 1 ohm, VNA can not provide accurate results with one port measurement ...
The Transformer Principle
... A transformer is an electrical device used to change the value of an alternating voltage. Transformers are widely used in electrical work. They are encountered daily, in industrial, commercial and domestic situations. They vary in size from miniature units used in electronics to huge units used in p ...
... A transformer is an electrical device used to change the value of an alternating voltage. Transformers are widely used in electrical work. They are encountered daily, in industrial, commercial and domestic situations. They vary in size from miniature units used in electronics to huge units used in p ...
ILX511 - Ocean Optics
... Note that the preceding notes should also be observed when removing a component from a board ...
... Note that the preceding notes should also be observed when removing a component from a board ...
PQ1 Power Quality Relay Full Data Sheet 1.20
... The wire cross section must be adequate for 100mA, and insulation must be adequate for the rated voltage. The PQ1 may be connected line-to-neutral or line-to-line. Do not connect any load, including the PQ1, from line-to-ground. If your PQ1 will be monitoring 277 Vrms, 400 Vrms, 480 Vrms, or higher, ...
... The wire cross section must be adequate for 100mA, and insulation must be adequate for the rated voltage. The PQ1 may be connected line-to-neutral or line-to-line. Do not connect any load, including the PQ1, from line-to-ground. If your PQ1 will be monitoring 277 Vrms, 400 Vrms, 480 Vrms, or higher, ...
Merlin 100-150 Load Bank Manual
... contactors and transformers. Check lugged wires at these components. 8. Inspect bottom of crate/enclosure for any components that may have jarred loose during shipment such as indicator light lenses, switch knobs, etc. 9. Visually inspect element chamber for foreign objects, broken ceramic insulator ...
... contactors and transformers. Check lugged wires at these components. 8. Inspect bottom of crate/enclosure for any components that may have jarred loose during shipment such as indicator light lenses, switch knobs, etc. 9. Visually inspect element chamber for foreign objects, broken ceramic insulator ...
unit-2: dc motor
... 1. Explain Swinburne’s test for finding the efficiency of a D.C. machine. Can this method Applicable to d.c. series motors. 2. Describe Hopkinson’s test in detail with its advantages disadvantages. 3. How the efficiency of each machine on full load is obtained from the regenerative test ? ...
... 1. Explain Swinburne’s test for finding the efficiency of a D.C. machine. Can this method Applicable to d.c. series motors. 2. Describe Hopkinson’s test in detail with its advantages disadvantages. 3. How the efficiency of each machine on full load is obtained from the regenerative test ? ...
VCS1610Z (Kelvin Connection)
... two-terminal resistor were used. In current sense resistors the contact resistance and the terminations resistance may be greater than that of the resistive element itself so lead connection errors can be significant if only two terminal connections are used. Why is the VCS1610Z vital in avoiding T ...
... two-terminal resistor were used. In current sense resistors the contact resistance and the terminations resistance may be greater than that of the resistive element itself so lead connection errors can be significant if only two terminal connections are used. Why is the VCS1610Z vital in avoiding T ...
Ü ÿ Ÿ - Tascam
... 10) Ventilation — Slots and openings in the cabinet are provided for ventilation and to ensure reliable operation of the product and to protect it from overheating, and these openings must not be blocked or covered. The openings should never be blocked by placing the product on a bed, sofa, rug, or ...
... 10) Ventilation — Slots and openings in the cabinet are provided for ventilation and to ensure reliable operation of the product and to protect it from overheating, and these openings must not be blocked or covered. The openings should never be blocked by placing the product on a bed, sofa, rug, or ...
OPAx22x High Precision, Low Noise
... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
Compact 224-Gbit/s Modulator Modules for Digital Coherent Optical
... minimize the package size, we located the input and output fibers on the same side of the package and RF interfaces on the opposite side. The modulator module size was only 34.0 × 16.5 × 6.0 mm3. Figure 8 (a) and (b) show small-signal E/O response and Sdd11 of each channel of modulators respectively ...
... minimize the package size, we located the input and output fibers on the same side of the package and RF interfaces on the opposite side. The modulator module size was only 34.0 × 16.5 × 6.0 mm3. Figure 8 (a) and (b) show small-signal E/O response and Sdd11 of each channel of modulators respectively ...
Old Company Name in Catalogs and Other Documents
... 4. Thermal derating factor is –5.0 mW/°C when operating ambient temperature is higher than 55°C. 5. Thermal derating factor is –4.4 mW/°C when operating ambient temperature is higher than 25°C. 6. Pay careful attention to the total power dissipation not to exceed the absolute maximum ratings, Note 4 ...
... 4. Thermal derating factor is –5.0 mW/°C when operating ambient temperature is higher than 55°C. 5. Thermal derating factor is –4.4 mW/°C when operating ambient temperature is higher than 25°C. 6. Pay careful attention to the total power dissipation not to exceed the absolute maximum ratings, Note 4 ...
NC7SZU04 TinyLogic UHS Unbuffered Inverter
... The NC7SZU04 is a single unbuffered inverter from Fairchild’s Ultra-High Speed series of TinyLogic®. The special purpose unbuffered circuit design is primarily intended for crystal oscillator or analog applications. The device is fabricated with advanced CMOS technology to achieve ultra-high speed w ...
... The NC7SZU04 is a single unbuffered inverter from Fairchild’s Ultra-High Speed series of TinyLogic®. The special purpose unbuffered circuit design is primarily intended for crystal oscillator or analog applications. The device is fabricated with advanced CMOS technology to achieve ultra-high speed w ...
NCL30086 Analog/Digital Dimmable Power Factor Corrected Quasi-Resonant Primary
... method, the device is able to tightly regulate a constant LED current from the primary side. This removes the need for secondary side feedback circuitry, biasing and an optocoupler. The device is highly integrated with a minimum number of external components. A robust suite of safety protection is b ...
... method, the device is able to tightly regulate a constant LED current from the primary side. This removes the need for secondary side feedback circuitry, biasing and an optocoupler. The device is highly integrated with a minimum number of external components. A robust suite of safety protection is b ...
49`er Availability
... There have been several inquiries as to the availability of the 49er kits. NorCal was given the rights to produce the 49er by Wayne Burkick, N6KR. He designed it as a simple project for the 1996 Dayton Building contest, never dreaming that it would become so popular. Wayne did not spend a lot of tim ...
... There have been several inquiries as to the availability of the 49er kits. NorCal was given the rights to produce the 49er by Wayne Burkick, N6KR. He designed it as a simple project for the 1996 Dayton Building contest, never dreaming that it would become so popular. Wayne did not spend a lot of tim ...
English
... 5. Carefully bend any excess wire length into the rear of the electrical box to allow enough room for the thermostat to be comfortably secured to the wall box without having to force it. Ensure that the wires are positioned so that the mounting screws will not damage the wire insulation when they ar ...
... 5. Carefully bend any excess wire length into the rear of the electrical box to allow enough room for the thermostat to be comfortably secured to the wall box without having to force it. Ensure that the wires are positioned so that the mounting screws will not damage the wire insulation when they ar ...
Grinder Pumps
... _____ Lightning arrestor. Protects the panel components and pump motor from electrical surges. _____ Anti-Condensation heater. A heater thermostat which protects panel components from condensing moisture by keeping the air temperature above dew point. _____ Alternator selector switch. Enables the op ...
... _____ Lightning arrestor. Protects the panel components and pump motor from electrical surges. _____ Anti-Condensation heater. A heater thermostat which protects panel components from condensing moisture by keeping the air temperature above dew point. _____ Alternator selector switch. Enables the op ...
Buck converter
A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.