• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
WIRE 1 = WIRE 2 = WIRE 3 - Bishopston Comprehensive School
WIRE 1 = WIRE 2 = WIRE 3 - Bishopston Comprehensive School

... When a fault develops and too much current flows into the appliance (through the plug) then the fuse wire will melt and disconnect the appliance from the supply saving the appliance. The fuse is always connected in the live part of the circuit. This is because it is only then can we be sure there is ...
An electronic symbol is a pictogram used to - PS
An electronic symbol is a pictogram used to - PS

... There are several national and international standards for graphical symbols in circuit diagrams, in particular: IEC 60617 (also known as British Standard BS 3939). ANSI standard Y32.2 (also known as IEEE Std 315). IEEE Std 91/91a: graphic symbols for logic functions (used in digital electronics). I ...
Introduction to SIDACtor® Devices
Introduction to SIDACtor® Devices

... For example, a customer loves the SOT553 package of the SP3003-02XTG, but needs a bit more VESD capability. You could use an SP3003-04XTG and combine the four channels into two. (As a bonus, the package becomes stubless through-line!) Of course the capacitance will double, but this may be acceptable ...
AVS2000 PRO
AVS2000 PRO

... Thank you for purchasing the Monster Power Professional Reference Automatic Voltage Stabilizer™AVS 2000 PRO. The AVS 2000 PRO is designed to stabilize power line fluctuations and maintain constant voltage to your professional components. Voltage sags (below the standard RMS value of 120 volts) are o ...
ee2257 control system laboratory 0 0 3 2
ee2257 control system laboratory 0 0 3 2

... When there is change in voltage applied to the field winding, the current through the field winding changes. This changes the flux produced by field winding. This motor has large Lf / Rf ratio, so time constant of this motor is high and it can’t give rapid responses to the quick changing control sig ...
TD001002EN
TD001002EN

... and Speakers for high fidelity sound output for indoor ceiling-mount applications. With the widest frequency response range (300 to 8000 Hz) in the industry, the Series LSPKC and LSPSTC feature leading intelligibility with crisp, clear voice messages and tone signaling, ideal for emergency communica ...
Power Supply Noise Analysis for Deep Sub
Power Supply Noise Analysis for Deep Sub

... • A methodology for decoupling capacitance allocation at floorplan level is proposed • Linear programming technique is used to allocate existing WS to maximize its utilization • A heuristic is proposed for additional WS insertion • Compared with “Greedy” solution, our method produces significantly s ...
ATX12V Power Supply Design Guide
ATX12V Power Supply Design Guide

Tracy  Elizabeth  Adams Cancer  Treatment
Tracy Elizabeth Adams Cancer Treatment

study of solution towards ground leakage current via inverter
study of solution towards ground leakage current via inverter

Interpretation of power phenomena in three phase systems with
Interpretation of power phenomena in three phase systems with

LM195/LM395 Ultra Reliable Power Transistors (Rev. C)
LM195/LM395 Ultra Reliable Power Transistors (Rev. C)

... type of overload. In the standard TO-3 transistor power package, the LM195 will deliver load currents in excess of 1.0A and can switch 40V in 500 ns. The inclusion of thermal limiting, a feature not easily available in discrete designs, provides virtually absolute protection against overload. Excess ...
Power Quality Issues and its Mitigation Techniques - ethesis
Power Quality Issues and its Mitigation Techniques - ethesis

NERC Synchronizing Islands
NERC Synchronizing Islands

... The frequencies of two islands will likely be different because the generation for each island being independently controlled. Before the circuit breaker can be closed the frequencies must be very close together and “in phase”. Think of a mechanical transmission that is about to lock two large machi ...
PowerPoint 프레젠테이션
PowerPoint 프레젠테이션

... Insulators are used principally to hold conductive elements in position and to prevent them from coming in contact with one another -> substrates on circuits. Ideal insulators :  r =1, tan  =0 ...
DS8313/DS8314 Smart Card Interface General Description Features
DS8313/DS8314 Smart Card Interface General Description Features

... for signals that interface with the host controller. It should, therefore, be the same supply as used by the host controller. All smart card contacts remain inactive during power-on or power-off. The internal circuits are kept in the reset state until VDD reaches VTH2 + VHYS2 and for the duration of ...
LM395T/NOPB - Texas Instruments High
LM395T/NOPB - Texas Instruments High

installation instructions
installation instructions

... 6. The emitter ports are driven in parallel with a 470 Ohm resistor connected in series with each port. The resistors ensure proper current sharing to each emitter. When using less than 4 emitters, you may plug them into any of the 4 emitter ports without regard to order. 7. Because of this current ...
MAX144/MAX145 Full Data Sheet (PDF)
MAX144/MAX145 Full Data Sheet (PDF)

... Input Bandwidth The MAX144/MAX145 T/H stage offers a 2.25MHz small-signal and a 1MHz full-power bandwidth, which make it possible to use the parts for digitizing high- speed transients and measuring periodic signals with bandwidths exceeding the ADCs sampling rate by using undersampling techniques. ...
VACUUM BOTTLE CIRCUIT BREAKER Application and Testing
VACUUM BOTTLE CIRCUIT BREAKER Application and Testing

User Manual of Brushless Speed Controller
User Manual of Brushless Speed Controller

... battery pack), and 0% means the low voltage cut-off function is disabled. For example: For a 6 cells NiMH battery, fully charged voltage is 1.44*6=8.64V, when “Medium” cut-off threshold is set, the cut-off voltage will be: 8.64*50%=4.32V。 5. Startup Mode:Normal /Soft /Super-Soft (300ms / 1.5s / 3s) ...
Design and Analysis of a Novel Multilevel Active-Clamped Power-Converter  T
Design and Analysis of a Novel Multilevel Active-Clamped Power-Converter T

... waveforms with better harmonic spectrum, and in most cases, increasing the efficiency of the power conversion system. However, a larger quantity of semiconductors is needed and the modulation strategy to control them becomes more complex. There are three basic multilevel converter topologies: diode ...
Circuit Note - Analog Devices
Circuit Note - Analog Devices

... corresponding to the soil pH. The measured pH is evaluated to determine if it is within the desired pH range for the specific crop to be grown. Method are then used to correct soil acidity by raising the pH (adding an acid neutralizer such as calcium), or by reducing alkalinity by lowering the pH (a ...
INVERTEK®
INVERTEK®

... Charging curves of the 3-state IUU type, with a boost phase and a floating phase. The 3-state charging characteristic, used on boats everywhere, saves on charging time. In addition, the charger can be adapted to all types of battery thanks to its 5 integral charging curves supervised by a micro cont ...
Self-induced Oscillations in Si and Other Semiconductors
Self-induced Oscillations in Si and Other Semiconductors

< 1 ... 478 479 480 481 482 483 484 485 486 ... 1789 >

Buck converter



A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report