Chapter 4 Specifying Simulation Output
... .PRINT DISTO HD2(M) HD2(DB) Prints the magnitude and decibel values of the second harmonic distortion component through the load resistor specified in the .DISTO statement (not shown). .PLOT NOISE INOISE ONOISE Note: The noise and distortion output variable may be specified along with other AC outpu ...
... .PRINT DISTO HD2(M) HD2(DB) Prints the magnitude and decibel values of the second harmonic distortion component through the load resistor specified in the .DISTO statement (not shown). .PLOT NOISE INOISE ONOISE Note: The noise and distortion output variable may be specified along with other AC outpu ...
Power Supply Unit: Transformer Skill: Diagnosing a transformer that
... A transformer is used in many electronic instruments. Sometimes, equipment is used in a different country than it was manufactured for. External transformers are used to adapt the equipment to the mains voltage difference. External transformers are also called wall transformers. The secondary voltag ...
... A transformer is used in many electronic instruments. Sometimes, equipment is used in a different country than it was manufactured for. External transformers are used to adapt the equipment to the mains voltage difference. External transformers are also called wall transformers. The secondary voltag ...
Electrical Injuries: Etiology, Pathophysiology and Mechanism of Injury
... Certain properties of electricity and tissue illustrate the mechanisms of electrical injury and the ability to predict patient’s outcomes. These properties include voltage, current, resistance, and conductance. Voltage is the electromotive force or the difference in the electrical potential. The cur ...
... Certain properties of electricity and tissue illustrate the mechanisms of electrical injury and the ability to predict patient’s outcomes. These properties include voltage, current, resistance, and conductance. Voltage is the electromotive force or the difference in the electrical potential. The cur ...
Motor Field Remote Supply 36C774345BAG01 Instructions
... modified by two additional inputs to the SREF AMP function. They are from the FIELD ECON and FIELD WEAK functions. Pulling point FE to COM will decrease the reference to go into field economy mode. The amount of weakening is adjusted by the FIELD ECON pot, PI. Similarly a weak field mode may be ente ...
... modified by two additional inputs to the SREF AMP function. They are from the FIELD ECON and FIELD WEAK functions. Pulling point FE to COM will decrease the reference to go into field economy mode. The amount of weakening is adjusted by the FIELD ECON pot, PI. Similarly a weak field mode may be ente ...
CA201001EN
... its Cooper Power™ series product line. Singlephase transformers are available as conventional (5-167kVA), completely self-protected (CSP 5-75kVA), or MagneX® interrupter-protected (5-167kVA) in a variety of ratings to meet or exceed the requirements of applicable ANSI® and NEMA® standards. Units des ...
... its Cooper Power™ series product line. Singlephase transformers are available as conventional (5-167kVA), completely self-protected (CSP 5-75kVA), or MagneX® interrupter-protected (5-167kVA) in a variety of ratings to meet or exceed the requirements of applicable ANSI® and NEMA® standards. Units des ...
Interface 1000 Potentiostat Brochure
... Front Panel, and eChem Toolkits allow users with some specialty ideas to run different tests, design their own software to control the Interface 1000, or integrate the Gamry system into a setup with other devices. Gamry can also provide custom solutions for non-standard experimental techniques that ...
... Front Panel, and eChem Toolkits allow users with some specialty ideas to run different tests, design their own software to control the Interface 1000, or integrate the Gamry system into a setup with other devices. Gamry can also provide custom solutions for non-standard experimental techniques that ...
Trajectory Sensitivities to Assess Influence of Components and
... Quantitative characterization of the impact of control devices (e.g., automatic voltage regulators, governors, load tap-changing transformers, static VAR compensators) across the transmission system have long been the objective of power system studies. Examples of methods used for such studies inclu ...
... Quantitative characterization of the impact of control devices (e.g., automatic voltage regulators, governors, load tap-changing transformers, static VAR compensators) across the transmission system have long been the objective of power system studies. Examples of methods used for such studies inclu ...
Complete 14-Bit CCD/CIS Signal Processor AD9822
... grounded, a 0 V input corresponds to the ADC’s zero-scale output. The OFFSET pin may also be used as a coarse offset adjust pin. A voltage applied to this pin is subtracted from the voltages applied to the red, green, and blue inputs in the first amplifier stage of the AD9822. The input clamp is dis ...
... grounded, a 0 V input corresponds to the ADC’s zero-scale output. The OFFSET pin may also be used as a coarse offset adjust pin. A voltage applied to this pin is subtracted from the voltages applied to the red, green, and blue inputs in the first amplifier stage of the AD9822. The input clamp is dis ...
1.4 Electrical Requirements (selection required)
... surge of the maximum rated surge current magnitude, followed by a second 6kV [1.2x50µs], 500 amp [8x20 s] impulse as a means of measuring clamping deviation (component degradation). Compliance is achieved if the two measured suppression voltage do not vary by more than 5%. Due to present industry t ...
... surge of the maximum rated surge current magnitude, followed by a second 6kV [1.2x50µs], 500 amp [8x20 s] impulse as a means of measuring clamping deviation (component degradation). Compliance is achieved if the two measured suppression voltage do not vary by more than 5%. Due to present industry t ...
LF to 2.5 GHz TruPwr™ Detector AD8361 Data Sheet
... 2.5 GHz. It is very easy to apply. It requires a single supply only between 2.7 V and 5.5 V, a power supply decoupling capacitor, and an input coupling capacitor in most applications. The output is a linear-responding dc voltage with a conversion gain of 7.5 V/V rms. An external filter capacitor can ...
... 2.5 GHz. It is very easy to apply. It requires a single supply only between 2.7 V and 5.5 V, a power supply decoupling capacitor, and an input coupling capacitor in most applications. The output is a linear-responding dc voltage with a conversion gain of 7.5 V/V rms. An external filter capacitor can ...
BD00GA3MEFJ-M
... diode or transistor. For example, the relation between each potential is as follows: When GND > Pin A and GND > Pin B, the P-N junction operates as a parasitic diode. When GND > Pin B, the P-N junction operates as a parasitic transistor. Parasitic diodes can occur inevitable in the structure of the ...
... diode or transistor. For example, the relation between each potential is as follows: When GND > Pin A and GND > Pin B, the P-N junction operates as a parasitic diode. When GND > Pin B, the P-N junction operates as a parasitic transistor. Parasitic diodes can occur inevitable in the structure of the ...
Final Report - WordPress@UP
... After initialization the code it is set in this state. The system can also be set into Calibration Mode if a recalibrate command is received, in which case it begins calibrating regardless of what mode it was previously in. In order for Calibration Mode to run properly, no object should be near the ...
... After initialization the code it is set in this state. The system can also be set into Calibration Mode if a recalibrate command is received, in which case it begins calibrating regardless of what mode it was previously in. In order for Calibration Mode to run properly, no object should be near the ...
parametric study of rotor slot shape on a cage induction motor
... the total bar cross-sectional area. If the number of the poles, supply frequency, voltage and output power do not change, then the terms on the right-hand side of equation (2) are practically constant. Therefore, in order to maintain the performance under nominal load the following is considered: Ab ...
... the total bar cross-sectional area. If the number of the poles, supply frequency, voltage and output power do not change, then the terms on the right-hand side of equation (2) are practically constant. Therefore, in order to maintain the performance under nominal load the following is considered: Ab ...
ZLLS410 Product Summary Features and Benefits
... Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. LIFE SUPPORT Diodes Incorporated products are specifically n ...
... Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. LIFE SUPPORT Diodes Incorporated products are specifically n ...
ignition testers
... systems by measuring its “PEAK VOLTAGE” and displaying it on an analogue meter. Oscilloscope waveforms are displayed on screens, which then needs to be interpreted by competent technicians. The oscilloscope, unlike the Imrie®630 does not easily display cranking speed voltages. An Imrie®630 is the id ...
... systems by measuring its “PEAK VOLTAGE” and displaying it on an analogue meter. Oscilloscope waveforms are displayed on screens, which then needs to be interpreted by competent technicians. The oscilloscope, unlike the Imrie®630 does not easily display cranking speed voltages. An Imrie®630 is the id ...
EGTOGET Seminar Topics
... # So the net torque goes from restraining to operating at some angular separation that is smaller than 90 degrees. # This angle is called the closing angle. # Some ijs relays have fixed closing angle while others have closing angles that are adjustable. The operating time of the ijs is determined ...
... # So the net torque goes from restraining to operating at some angular separation that is smaller than 90 degrees. # This angle is called the closing angle. # Some ijs relays have fixed closing angle while others have closing angles that are adjustable. The operating time of the ijs is determined ...
Cutler-Hammer
... Dimensions of Enclosed Automatic Transfer Switch and Approximate Weights .....................................12 Typical (30-150 Amperes) Horizontal Design Transfer Switch Equipment (Door Open).........................13 Typical (225-1000 Amperes) Vertical Design Transfer Switch Equipment (Door Open ...
... Dimensions of Enclosed Automatic Transfer Switch and Approximate Weights .....................................12 Typical (30-150 Amperes) Horizontal Design Transfer Switch Equipment (Door Open).........................13 Typical (225-1000 Amperes) Vertical Design Transfer Switch Equipment (Door Open ...
THROTTLE POSITION SENSOR (TPS)—FUNCTION
... information from these three (3) areas based on vehicle load to generate three (3) independent values. The three (3) independent values will be continuously monitored by the PCM. If one (1) of the values differs significantly from the others during normal vehicle operation, a Continuous Memory Diagn ...
... information from these three (3) areas based on vehicle load to generate three (3) independent values. The three (3) independent values will be continuously monitored by the PCM. If one (1) of the values differs significantly from the others during normal vehicle operation, a Continuous Memory Diagn ...
Secondary-Side Controller with Current Share and Housekeeping ADM1041A
... bringing down the load voltage that is supplied by the redundant configuration of other power supplies. In the case of a short, a reverse voltage is generated across the OrFET. This reverse voltage is detected by the ADM1041A and the OrFET is shut down via the FG pin. This intervention prevents any ...
... bringing down the load voltage that is supplied by the redundant configuration of other power supplies. In the case of a short, a reverse voltage is generated across the OrFET. This reverse voltage is detected by the ADM1041A and the OrFET is shut down via the FG pin. This intervention prevents any ...
Chapter 9 AC Sweep and Signal Analysis
... .DISTO Statement — AC Small-Signal Distortion Analysis The .DISTO statement causes Star-Hspice to compute the distortion characteristics of the circuit in an AC small-signal, sinusoidal, steady-state analysis.The program computes and reports five distortion measures at the specified load resistor. T ...
... .DISTO Statement — AC Small-Signal Distortion Analysis The .DISTO statement causes Star-Hspice to compute the distortion characteristics of the circuit in an AC small-signal, sinusoidal, steady-state analysis.The program computes and reports five distortion measures at the specified load resistor. T ...
Buck converter
A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.