• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
HF Resonators for Damping of VFTs in GIS
HF Resonators for Damping of VFTs in GIS

... parameter in Equation (11). According to [9], the Fourier transformation of the burst (13) is also a Gaussian exponential function in frequency domain (Figure 3 – right) with the width around the central frequency f0. Thus, by defining Gaussian burst in time-domain by Equations (11-13), it is possib ...
analogue meters
analogue meters

Innovative Techniques for Extremely Low Power Consumption with
Innovative Techniques for Extremely Low Power Consumption with

Variable Frequency Drives for conveyor starting
Variable Frequency Drives for conveyor starting

... Other soft starter devices can limit the torque but they do this in a less controlled manner. A fluid coupling works on the principle of creating a mechanical slip between the motor and the driven load. The motor still provides its normal high starting torque and high starting current. Instead of a ...
Vario (Spektrum) Manual Version 1.3
Vario (Spektrum) Manual Version 1.3

... prevent address conflicts, you can disable sensor addresses on the Vspeak-Vario. All measured data can also be logged by VSpeak-Vario - and - with the help of Logview clearly ...
Digital Panel Meters - Datel Digital Meters
Digital Panel Meters - Datel Digital Meters

A Reference Design for DWDM Pump Lasers
A Reference Design for DWDM Pump Lasers

... The temperature of the laser diode is critical in maintaining a constant wavelength, so it must be controlled. This can be challenging, because as significant current is driven into the laser diode to provide the power desired, the temperature cannot change. These systems address this problem by usi ...
Resistors
Resistors

... 12 values) we have all possible values available to us. So, if we wanted a 17.5 Ohm resistor, the nearest value is 18 Ohms. But this resistor has a range of 16.2 Ohms to 19.8 Ohms, which includes the value we want. However, our 18 Ohm resistor could have a value of 16.5 Ohms or 19 Ohms. If we wanted ...
LightHAWK®2 Wall Switch Occupancy Sensors
LightHAWK®2 Wall Switch Occupancy Sensors

... The sensor is equipped with Hubbell Building Automation’s patented self-adaptive IntelliDAPT® technology which automatically adjusts the sensor’s sensitivity and timer settings to optimize performance based on occupancy patterns. The sensor constantly learns and adjusts appropriately. If the learned ...
Film Capacitors – Power Factor Correction
Film Capacitors – Power Factor Correction

...  In case of the presence of harmonics installation of a de-tuned capacitor bank (reactors) must be considered.  Check the discharge resistors/reactors and in case of doubt, check their function: (1) Power the capacitor up and down. (2) After ≤ 90 seconds the voltage between the terminals must decl ...
Basics of Branch Circuit Testing
Basics of Branch Circuit Testing

- Piranha Offroad
- Piranha Offroad

615-4740 (45-075) Induction Kit
615-4740 (45-075) Induction Kit

... electro motive force in the other coil will reverse 100 times per second. Because this is so rapid the meter mechanism will not be capable of moving that fast and will appear as a slight vibration and then will appear stationary. At this point, connect an AC voltmeter or better still an oscilloscope ...
Datasheet - Infineon Technologies
Datasheet - Infineon Technologies

... capacitor when the LEDs are disconnected. Two types of output bleeder are available for the user to choose. For passive bleeders, short pins 1 2 of J101. For active bleeders, short pins 2 3 of J101 and pins 1 2 of J102. The disadvantage of passive bleeders is that the design will take a hit in effic ...
UltraVolt, Inc. - Application Notes for High Voltage Power Supplies
UltraVolt, Inc. - Application Notes for High Voltage Power Supplies

... and are unique to each model. The HV Multiplier in each high-voltage power supply is grounded through the Rsense resistor, as shown in Figure 1. The HV Feedback resistors and the HV Test Point resistors are returned to ground and are seen by the power supply as an internal load. This internal load i ...
Grin Technologies SineWave Grinfineon Controller User
Grin Technologies SineWave Grinfineon Controller User

ENGG 3640: Microcomputer Interfacing
ENGG 3640: Microcomputer Interfacing

Battery Model: D31A Part Number: 8051
Battery Model: D31A Part Number: 8051

... Constant Voltage chargers, amperage will taper down as the battery becomes recharged. When amperage drops below 1 amp, the battery will be close to a full state of charge. (All charge recommendations assume an average room temperature of 77°F (25°C). Always wear safety glasses when working with batt ...
T est Line - P erforation counter PZ 3
T est Line - P erforation counter PZ 3

... that may be triggered by "holes" in the film and should not be ...
Aalborg Universitet A Comprehensive Review of Low-Voltage-Ride-Through Methods for Fixed-Speed
Aalborg Universitet A Comprehensive Review of Low-Voltage-Ride-Through Methods for Fixed-Speed

... Recently, many power system operators in Europe and other regions of the world have begun expanding and modifying their interconnection requirements for wind farms through technical standards, known as grid codes [9, 10]. One of the critical requirements concerning the grid voltage support is the lo ...
How to troubleshoot why the drive won`t follow a speed reference
How to troubleshoot why the drive won`t follow a speed reference

... that there is +10V at terminal 22 with terminal 5 as the common or check that the value changes correctly with (P16 if Analog In1) and (P17 if Analog In2). Note :> When using 4-20ma current source check that the value changes correctly with – (P16 if Analog In1) and (P17 if Analog In2). Note :> “Che ...
How to Select the Correct Temperature Sensor Application Note
How to Select the Correct Temperature Sensor Application Note

Digital electronic drivers type E-MI-AS-IR
Digital electronic drivers type E-MI-AS-IR

... Different ramp mode can be set: - single ramp for any reference variation - two ramps for increasing and for decreasing reference variations Ramp generator is useful for application where smooth hydraulic actuation is necessary to avoid machine vibration and shocks; if the proportional valve is driv ...
GSTQ004
GSTQ004

... permanent and reliable IP connection. Aggregated and calculated indices (such as percentile values) could also be inserted in these databases. o WEATHER DATABASES, collecting data from external weather information services. o GRID EVENTS DATABASES: these units collect basic information about trippin ...
From 10 to 100 kVA
From 10 to 100 kVA

... and upgradability, the M4T range can be configured in parallel. Up to 3 units can be connected in parallel using two connectors, increasing the power and redundancy for even greater security. The «in parallel» function is built into the UPS and is therefore configurable for free. ...
< 1 ... 396 397 398 399 400 401 402 403 404 ... 1789 >

Buck converter



A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report