IA ISM-AN2 REV 1.0 0604.pmd - All
... is about 2 times higher. Under certain regulations, given either in ERP, EIRP, or field strength limitation by the U.S. FCC (Note 1) or European ETSI (Note 2) standards, the allowed radiation power is lower than the available maximum power from the transmitter. In those cases, the range correspondin ...
... is about 2 times higher. Under certain regulations, given either in ERP, EIRP, or field strength limitation by the U.S. FCC (Note 1) or European ETSI (Note 2) standards, the allowed radiation power is lower than the available maximum power from the transmitter. In those cases, the range correspondin ...
Leeson Basic Training Manual
... Another commonly used motor in industrial applications is the direct current motor. It is often used in applications where adjustable speed control is required. Permanent magnet DC designs are generally used for motors that produce less than 5 HP. Larger horsepower applications use shunt-wound direc ...
... Another commonly used motor in industrial applications is the direct current motor. It is often used in applications where adjustable speed control is required. Permanent magnet DC designs are generally used for motors that produce less than 5 HP. Larger horsepower applications use shunt-wound direc ...
CYB_STS_1600A-4000A_Guideform Spec
... The cooling design shall use air filters along with multiple (2 or more) redundant fans sized to provide cooling to critical component areas. The SCR’s shall be oversized to a degree that the unit has capability to operate at full capacity (including overload rating) to allow overload clearing by ...
... The cooling design shall use air filters along with multiple (2 or more) redundant fans sized to provide cooling to critical component areas. The SCR’s shall be oversized to a degree that the unit has capability to operate at full capacity (including overload rating) to allow overload clearing by ...
MAX9311/MAX9313 1:10 Differential LVPECL/LVECL/HSTL Clock and Data Drivers General Description
... The MAX9311/MAX9313 are low skew, 1-to-10 differential drivers designed for clock and data distribution. A 2:1 mux selects between the two differential inputs, CLK0, CLK0 and CLK1, CLK1. The 2:1 mux is switched by the single-ended CLKSEL input. A logic low selects the CLK0, CLK0 input. A logic high ...
... The MAX9311/MAX9313 are low skew, 1-to-10 differential drivers designed for clock and data distribution. A 2:1 mux selects between the two differential inputs, CLK0, CLK0 and CLK1, CLK1. The 2:1 mux is switched by the single-ended CLKSEL input. A logic low selects the CLK0, CLK0 input. A logic high ...
DLP9000FLS 0.9 WQXGA Type A DMD (Rev. B)
... direction, and/or phase of incoming light. This advanced light control technology has numerous applications in the industrial, medical, and consumer markets. The streaming nature of the DLP9000XFLS and its DLPC910 controller enable very high speed continuous data streaming for lithographic applicati ...
... direction, and/or phase of incoming light. This advanced light control technology has numerous applications in the industrial, medical, and consumer markets. The streaming nature of the DLP9000XFLS and its DLPC910 controller enable very high speed continuous data streaming for lithographic applicati ...
Oscillators
... The crystal is inductive only between the frequencies fs and fp. The frequency of oscillation must lie between these frequencies. Hence the stability. ...
... The crystal is inductive only between the frequencies fs and fp. The frequency of oscillation must lie between these frequencies. Hence the stability. ...
Whats a Servo
... So, how does a servo work? The servo motor has some control circuits and a potentiometer (a variable resistor, aka pot) that is connected to the output shaft. In the picture above, the pot can be seen on the right side of the circuit board. This pot allows the control circuitry to monitor the curre ...
... So, how does a servo work? The servo motor has some control circuits and a potentiometer (a variable resistor, aka pot) that is connected to the output shaft. In the picture above, the pot can be seen on the right side of the circuit board. This pot allows the control circuitry to monitor the curre ...
Activity 3A
... The electrical relay offers a simple ON/OFF switching action in response to a control signal. Figure 3.2 illustrates the principle. When a current flows through the coil of wire a magnetic field is produced. This pulls a movable arm that forces the contact to open or close. This might then be used t ...
... The electrical relay offers a simple ON/OFF switching action in response to a control signal. Figure 3.2 illustrates the principle. When a current flows through the coil of wire a magnetic field is produced. This pulls a movable arm that forces the contact to open or close. This might then be used t ...
SB800 - Marathon Motors Basic Training Manual
... An electric motor’s principle of operation is based on the fact that a current-carrying conductor, when placed in a magnetic field, will have a force exerted on the conductor proportional to the current flowing in the conductor and to the strength of the magnetic field. In alternating current motors ...
... An electric motor’s principle of operation is based on the fact that a current-carrying conductor, when placed in a magnetic field, will have a force exerted on the conductor proportional to the current flowing in the conductor and to the strength of the magnetic field. In alternating current motors ...
$doc.title
... ADC topology [41, 85, 88], which is illustrated in Figure 1.1. These ADCs are used for a number of applications, e.g., read channel applications presented in Section 1.1 and in ultra wideband (UWB) radio applications presented in Section 1.2. As seen in Figure 1.1 the input signal of a flash ADC is ...
... ADC topology [41, 85, 88], which is illustrated in Figure 1.1. These ADCs are used for a number of applications, e.g., read channel applications presented in Section 1.1 and in ultra wideband (UWB) radio applications presented in Section 1.2. As seen in Figure 1.1 the input signal of a flash ADC is ...
... Normally open contacts are shown as two lines, and will be open (non-conducting) when the input is not energized. Normally closed contacts are shown with two lines with a diagonal line through them. When the input coil is not energized the normally closed contacts will be closed (conducting). Relays ...
FDC10 10 Series of Power Moudules : DC/DC Converter
... • No minimum load • Low output ripple and noise • Fixed switching frequency (300KHz) • Remote ON/OFF • Input under-voltage lockout • Output over-current protection • Over temperature protection • Cost – efficient open frame design • ISO 9001 certified manufacturing facilities • UL 60950-1 and CB pen ...
... • No minimum load • Low output ripple and noise • Fixed switching frequency (300KHz) • Remote ON/OFF • Input under-voltage lockout • Output over-current protection • Over temperature protection • Cost – efficient open frame design • ISO 9001 certified manufacturing facilities • UL 60950-1 and CB pen ...
16480 VARIABLE SPEED DRIVES
... signal the loss-of-load condition via a keypad warning, Form-C relay output, and / or over the serial communications bus. The loss-of-load condition sensing algorithm shall include a programmable time delay that will allow for motor acceleration from zero speed without signaling a false loss-of-load ...
... signal the loss-of-load condition via a keypad warning, Form-C relay output, and / or over the serial communications bus. The loss-of-load condition sensing algorithm shall include a programmable time delay that will allow for motor acceleration from zero speed without signaling a false loss-of-load ...
IFS-2600 Install and Programming Manual
... Illuminates if batteries are disconnected >30 seconds. Illuminates if batteries are short circuit >30 seconds. Illuminates if the power supply is outside the manufacturers range. (Also if power supply is disconnected) Illuminates if the battery charger is outside the recommended float charge voltage ...
... Illuminates if batteries are disconnected >30 seconds. Illuminates if batteries are short circuit >30 seconds. Illuminates if the power supply is outside the manufacturers range. (Also if power supply is disconnected) Illuminates if the battery charger is outside the recommended float charge voltage ...
Ultra Linear Low-Loss Varactor Diode Configurations for Adaptive RF Systems
... comes from strong out-of-band interferers whose undesired mixing products can fall in-band and pollute the reception of the desired signal. Note that in practical situations these interfering or jammer signals are typically separated from the desired signal by more than 100 kHz. As result the linear ...
... comes from strong out-of-band interferers whose undesired mixing products can fall in-band and pollute the reception of the desired signal. Note that in practical situations these interfering or jammer signals are typically separated from the desired signal by more than 100 kHz. As result the linear ...
Operating Experience Assessment - Effects of Grid Performance
... few years. Whereas before, electric utilities produced the electricity and operated the transmission and distribution system, that is no longer the case. In many states, the electric utilities have split into separate generating companies, and transmission and distribution companies, thereby increas ...
... few years. Whereas before, electric utilities produced the electricity and operated the transmission and distribution system, that is no longer the case. In many states, the electric utilities have split into separate generating companies, and transmission and distribution companies, thereby increas ...
26 13 00-Medium Voltage Switchgear
... Interrupter switches shall be operated by means of an externally accessible 3/4" hex switch-operating hub. The switch-operating hub shall be located within a recessed stainless-steel pocket mounted on the side of the pad-mounted gear enclosure and shall accommodate a 3/4" deep-socket wrench or a 3/4 ...
... Interrupter switches shall be operated by means of an externally accessible 3/4" hex switch-operating hub. The switch-operating hub shall be located within a recessed stainless-steel pocket mounted on the side of the pad-mounted gear enclosure and shall accommodate a 3/4" deep-socket wrench or a 3/4 ...
Buck converter
A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.