![M CMOS-MEMS R](http://s1.studyres.com/store/data/008910000_1-6a615a9cda8a396c2e37bd2fc8c14ee3-300x300.png)
M CMOS-MEMS R
... Resonant beams structures are very attractive transducers for physical, chemical and biological sensors based on micro-/nanoelectromechanical systems (M-/NEMS) due to its simplicity, wide range of sensing domains, and extremely high sensitivity. This Ph.D. thesis is focused on the design, fabricatio ...
... Resonant beams structures are very attractive transducers for physical, chemical and biological sensors based on micro-/nanoelectromechanical systems (M-/NEMS) due to its simplicity, wide range of sensing domains, and extremely high sensitivity. This Ph.D. thesis is focused on the design, fabricatio ...
C21 Dimming System
... 7.) IGBT dual dimmer modules shall be available with current ratings of 20 amps. IGBT single dimmer modules shall be available with current ratings of 50 amps. Each module shall offer full dimmer status reporting to match all other modules in the C21 Advanced Technology product family. IGBT Dimmer m ...
... 7.) IGBT dual dimmer modules shall be available with current ratings of 20 amps. IGBT single dimmer modules shall be available with current ratings of 50 amps. Each module shall offer full dimmer status reporting to match all other modules in the C21 Advanced Technology product family. IGBT Dimmer m ...
The development of a miniaturized hydration sensor
... interface containing a resistive pressure transducer together with an ASIC and a few discrete components assembled on a silicon substrate. The sensor has a cavity (reference chamber) with a pressure transducer used to record the osmotic pressure induced by the physical ...
... interface containing a resistive pressure transducer together with an ASIC and a few discrete components assembled on a silicon substrate. The sensor has a cavity (reference chamber) with a pressure transducer used to record the osmotic pressure induced by the physical ...
PowerWorx SuperPower GMT Series
... WARNING presents safety information to PREVENT INJURY OR DEATH to personnel. Warnings are indicated by a shock hazard icon, the word WARNING, and a rule beneath which the information appears. ...
... WARNING presents safety information to PREVENT INJURY OR DEATH to personnel. Warnings are indicated by a shock hazard icon, the word WARNING, and a rule beneath which the information appears. ...
Negotiated Customer Connection Contract
... commutation of power electronic equipment, harmonic resonance and other effects within the plant, must not exceed the THDv limits set out in Table 3 (determined in accordance with Rule S5.1.6(a)). Minor exceedances of individual harmonics will be accepted provided the THDv limits are not exceeded. ...
... commutation of power electronic equipment, harmonic resonance and other effects within the plant, must not exceed the THDv limits set out in Table 3 (determined in accordance with Rule S5.1.6(a)). Minor exceedances of individual harmonics will be accepted provided the THDv limits are not exceeded. ...
please note that catalog is being updated!
... Fig. 1. The matrix is nonblocking, but not full fan-out. Nonblocking means that any input can be connected to any output without interrupting a previously set path. When a matrix is not full fanout, an input may be switched to only one output. Matrix configurations from 2x2 to 8x8 or larger are poss ...
... Fig. 1. The matrix is nonblocking, but not full fan-out. Nonblocking means that any input can be connected to any output without interrupting a previously set path. When a matrix is not full fanout, an input may be switched to only one output. Matrix configurations from 2x2 to 8x8 or larger are poss ...
AVR2016: RZRAVEN Hardware User`s Guide
... 2.12.2 Relay Interface A relay interface (Relay Positive and Negative) is available through J401. This interface can be used with the AVRRAVEN running from external power. A switching transistor is connected to PB6 on the ATmega3290P so that sufficient current can be provided to the relay being driv ...
... 2.12.2 Relay Interface A relay interface (Relay Positive and Negative) is available through J401. This interface can be used with the AVRRAVEN running from external power. A switching transistor is connected to PB6 on the ATmega3290P so that sufficient current can be provided to the relay being driv ...
JTAG-SMT2-NC™ Programming Module for Xilinx® FPGAs Overview
... high-impedance state until a host application enables DPIO port 0 and configures the applicable pin as an output. When the host application disables DPIO port 0, all GPIO pins revert to a high-impedance state. Weak pull-ups (100K ohm) ensure that the GPIO signals do not float while not being activel ...
... high-impedance state until a host application enables DPIO port 0 and configures the applicable pin as an output. When the host application disables DPIO port 0, all GPIO pins revert to a high-impedance state. Weak pull-ups (100K ohm) ensure that the GPIO signals do not float while not being activel ...
English - SMC ETech
... specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product re ...
... specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product re ...
Shielded Metal Arc Welding (SMAW) - Part A
... current that causes the arc to flare uncontrollably from side to side. Puddle control is very difficult and the subsequent weld quality is very poor. Arc blow is caused by magnetic fields being set up around the work. This is due to current travelling in the same direction for a prolonged period of ...
... current that causes the arc to flare uncontrollably from side to side. Puddle control is very difficult and the subsequent weld quality is very poor. Arc blow is caused by magnetic fields being set up around the work. This is due to current travelling in the same direction for a prolonged period of ...
User Guide - Eurotherm
... EPower™ Power management and control units Versions 3.06 and later HA179769 Issue 11 December 2015 ...
... EPower™ Power management and control units Versions 3.06 and later HA179769 Issue 11 December 2015 ...
Instructions for Installation, Operation, and Maintenance
... commonly known as the National Electrical Code (NEC), OSHA, and local procedures and standards. This includes visual inspections while the vertical section door is open, making any adjustments inside or outside the switchgear vertical section, performing maintenance, or installing replacement parts. ...
... commonly known as the National Electrical Code (NEC), OSHA, and local procedures and standards. This includes visual inspections while the vertical section door is open, making any adjustments inside or outside the switchgear vertical section, performing maintenance, or installing replacement parts. ...
V - KOBRA
... 3.13 Transient simulated temperature and exponential fitting: (a) the channel under individual fingers, (b) 2nd order fitting and inset shows fast transient at 1µsec range… ...
... 3.13 Transient simulated temperature and exponential fitting: (a) the channel under individual fingers, (b) 2nd order fitting and inset shows fast transient at 1µsec range… ...
PL 3120®/PL 3150®/PL 3170
... Parts manufactured by vendors other than Echelon and referenced in this document have been described for illustrative purposes only, and may not have been tested by Echelon. It is the responsibility of the customer to determine the suitability of these parts for each application. ECHELON MAKES AND Y ...
... Parts manufactured by vendors other than Echelon and referenced in this document have been described for illustrative purposes only, and may not have been tested by Echelon. It is the responsibility of the customer to determine the suitability of these parts for each application. ECHELON MAKES AND Y ...
700-2.14: Safety Relays
... • Is designed with an internal circuit that will allow power to be removed from a load even if an internal contact welds. • The internal circuit is redundant and self–monitoring, using multiple, positive–guided relays. • Monitors faults in the safety relay, and the input (e.g. Start and Stop Buttons ...
... • Is designed with an internal circuit that will allow power to be removed from a load even if an internal contact welds. • The internal circuit is redundant and self–monitoring, using multiple, positive–guided relays. • Monitors faults in the safety relay, and the input (e.g. Start and Stop Buttons ...
1.4 Harmonic Filter Bank Elevation
... consists of large variable speed drives and cyclo-converters. The filter system consists of Chigh-pass, standard high-pass, and notch filter branches. The filter branches are switched and controlled by a remote central protection and control system to be provided by the vendor. The control system mu ...
... consists of large variable speed drives and cyclo-converters. The filter system consists of Chigh-pass, standard high-pass, and notch filter branches. The filter branches are switched and controlled by a remote central protection and control system to be provided by the vendor. The control system mu ...
MC33794 E-field Sensor Reference Manual
... MC33794/MC34940 can detect electric field variations in up to 9 electrodes and transform these variations into an analog signal. This signal can be interfaced directly with a 5V micro controller A/D module. Based on this E-Field sensor, this reference design detects human presence through glass or o ...
... MC33794/MC34940 can detect electric field variations in up to 9 electrodes and transform these variations into an analog signal. This signal can be interfaced directly with a 5V micro controller A/D module. Based on this E-Field sensor, this reference design detects human presence through glass or o ...
Buck converter
A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.