FAN3988 USB/Charger and Over-Voltage Detection Device FAN 39
... LOW if VBUS is less than 3.3 V or greater than 6.0 V. ...
... LOW if VBUS is less than 3.3 V or greater than 6.0 V. ...
Aalborg Universitet Turbine Systems
... same values for the transient time. The differences can be seen in the steady-state condition with 3% difference between the lowest thermal impedance and the highest one. The reason originates from the dependency of materials thermal conductivity to temperature variation, especially in higher loadin ...
... same values for the transient time. The differences can be seen in the steady-state condition with 3% difference between the lowest thermal impedance and the highest one. The reason originates from the dependency of materials thermal conductivity to temperature variation, especially in higher loadin ...
MAX11162 16-Bit, 500ksps, +5V Unipolar Input, SAR ADC, in Tiny 10-Pin µMAX
... Serial Data Input and Mode Select Input. Daisy-chain mode is selected if SDI is low during the CNVST rising edge. In this mode, SDI is used as a data input to daisy-chain the conversion results of two or more ADCs onto a single SDO line. CS mode is selected if SDI is high during the CNVST rising edg ...
... Serial Data Input and Mode Select Input. Daisy-chain mode is selected if SDI is low during the CNVST rising edge. In this mode, SDI is used as a data input to daisy-chain the conversion results of two or more ADCs onto a single SDO line. CS mode is selected if SDI is high during the CNVST rising edg ...
MRF175GU MRF175GV The RF MOSFET Line 200/150W, 500MHz, 28V
... When shipping, the devices should be transported only in antistatic bags or conductive foam. Upon removal from the packaging, careful handling procedures should be adhered to. Those handling the devices should wear grounding straps and devices not in the antistatic packaging should be kept in metal ...
... When shipping, the devices should be transported only in antistatic bags or conductive foam. Upon removal from the packaging, careful handling procedures should be adhered to. Those handling the devices should wear grounding straps and devices not in the antistatic packaging should be kept in metal ...
RF current element design for independent control of current
... pulses (7), which allows selective excitation of specific regions of interest and optimization of B1 field homogeneity (4), has further contributed to the increased interest in parallel transmit coils (5). A parallel transmit coil with independent control of the rung current amplitude and phase may be ...
... pulses (7), which allows selective excitation of specific regions of interest and optimization of B1 field homogeneity (4), has further contributed to the increased interest in parallel transmit coils (5). A parallel transmit coil with independent control of the rung current amplitude and phase may be ...
switchgear - Siemens Industry, Inc.
... alkaline cleaner, fresh water rise, iron phosphate treatment, fresh water rise and non-chromate sealer. After cleaning and stabilization, the steel parts shall be coated with a thermosetting polyester powder applied with electrostatic equipment at a nominal 2 mils dry film thickness and then cured p ...
... alkaline cleaner, fresh water rise, iron phosphate treatment, fresh water rise and non-chromate sealer. After cleaning and stabilization, the steel parts shall be coated with a thermosetting polyester powder applied with electrostatic equipment at a nominal 2 mils dry film thickness and then cured p ...
8. Electric Power AP1000 Design Control Document
... Bus tie breakers are provided between two 480 V load centers each serving predominantly redundant loads. This intertie allows restoration of power to selected loads in the event of a failure or maintenance of a single load center transformer. The bus tie breakers are interlocked with the correspondi ...
... Bus tie breakers are provided between two 480 V load centers each serving predominantly redundant loads. This intertie allows restoration of power to selected loads in the event of a failure or maintenance of a single load center transformer. The bus tie breakers are interlocked with the correspondi ...
MAX1206 40Msps, 12-Bit ADC General Description Features
... an externally applied reference. A common-mode reference is provided to simplify design and reduce external component count in differential analog input circuits. The MAX1206 supports both a single-ended and differential input clock drive. Wide variations in the clock duty cycle are compensated with ...
... an externally applied reference. A common-mode reference is provided to simplify design and reduce external component count in differential analog input circuits. The MAX1206 supports both a single-ended and differential input clock drive. Wide variations in the clock duty cycle are compensated with ...
A Tutorial on Calculating Source Impedance Ratios
... voltage transformer (VT) and the protective relay?” A typical capacitor-coupled voltage transformer (CVT) used for protection has an accuracy of at least 1 percent (steady state) and a transient response of less than 10 percent in the first cycle. Protective relays typically have a transient accurac ...
... voltage transformer (VT) and the protective relay?” A typical capacitor-coupled voltage transformer (CVT) used for protection has an accuracy of at least 1 percent (steady state) and a transient response of less than 10 percent in the first cycle. Protective relays typically have a transient accurac ...
Trame Rapport
... It is advisable to check that the installation will not be subjected to overvoltage of any kind (atmospheric or switching overvoltage). - If there is a risk, the transformer should be protected by phase-earth surge arresters installed directly on the MV connection terminals (top or bottom). Phase-ea ...
... It is advisable to check that the installation will not be subjected to overvoltage of any kind (atmospheric or switching overvoltage). - If there is a risk, the transformer should be protected by phase-earth surge arresters installed directly on the MV connection terminals (top or bottom). Phase-ea ...
Effect of Neutral Grounding Methods on the Earth Fault
... in [5–8] studied the system currents and voltages behavior during fault, for the different system parameters. Isolated neutral systems have small fault current levels. These currents depend generally on the capacitances between the phases and the ground. Many researchers developed protection algorit ...
... in [5–8] studied the system currents and voltages behavior during fault, for the different system parameters. Isolated neutral systems have small fault current levels. These currents depend generally on the capacitances between the phases and the ground. Many researchers developed protection algorit ...
... 11/2 inches to 1% inches, more or less, when said motor M is operating. This is distinctly ad In the event that the ticker mechanism P ejects the tape at a faster rate than it is drawn - vantageous. With such an arrangement, the in formation ebtained by observation of the pro by the motor M, when en ...
VFD
... Motor leads on a VFD unit can cause noise in adjacent wiring. Consider using special VFD wiring on new installations. Some VFD installations may require air circulation around the drive unit if installed in an outdoor enclosure or in a hot environment. ...
... Motor leads on a VFD unit can cause noise in adjacent wiring. Consider using special VFD wiring on new installations. Some VFD installations may require air circulation around the drive unit if installed in an outdoor enclosure or in a hot environment. ...
Heavy Fog Glaciator - Martin Professional
... heat exchanger until it is at a temperature lower than the ambient in which the machine is operating. Air is added to the smoke, prior to cooling, from the fan mounted in the rear of the machine. This increases the volume of the effect and allows the output to be pushed through ducting. A fluid cont ...
... heat exchanger until it is at a temperature lower than the ambient in which the machine is operating. Air is added to the smoke, prior to cooling, from the fan mounted in the rear of the machine. This increases the volume of the effect and allows the output to be pushed through ducting. A fluid cont ...
MAX9370/MAX9371/MAX9372 LVTTL/TTL-to-Differential LVPECL/PECL Translators General Description
... The MAX9370/MAX9371/MAX9372 LVTTL/TTL-to-differential LVPECL/PECL translators are designed for highspeed communication signal and clock driver applications. The MAX9370/MAX9372 are dual LVTTL/TTL-to-LVPECL/PECL translators that operate in excess of 1GHz. The MAX9371 is a single translator. The MAX93 ...
... The MAX9370/MAX9371/MAX9372 LVTTL/TTL-to-differential LVPECL/PECL translators are designed for highspeed communication signal and clock driver applications. The MAX9370/MAX9372 are dual LVTTL/TTL-to-LVPECL/PECL translators that operate in excess of 1GHz. The MAX9371 is a single translator. The MAX93 ...
NX3DV2567 1. General description Low-ohmic four-pole double-throw analog switch
... 1. General description The NX3DV2567 is a four-pole double-throw analog switch (4PDT) optimized for switching WLAN-SIM supply, data and control signals. It has one digital select input (S) and four switches each with two independent input/outputs (nY0 and nY1) and a common input/output (nZ). Schmitt ...
... 1. General description The NX3DV2567 is a four-pole double-throw analog switch (4PDT) optimized for switching WLAN-SIM supply, data and control signals. It has one digital select input (S) and four switches each with two independent input/outputs (nY0 and nY1) and a common input/output (nZ). Schmitt ...
Buck converter
A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.