AP1121
... 3. See thermal regulation specifications for changes in output voltage due to heating effects. Line and load regulation are measured at a constant junction temperature by low duty cycle pulse testing. Load regulation is measured at the output lead = 1/18” from the package. 4. Line and load regulatio ...
... 3. See thermal regulation specifications for changes in output voltage due to heating effects. Line and load regulation are measured at a constant junction temperature by low duty cycle pulse testing. Load regulation is measured at the output lead = 1/18” from the package. 4. Line and load regulatio ...
+ info - Aplicaciones Tecnológicas | Lightning protection, surge
... Install in parallel with the Low Voltage supply line, connected to line, neutral and to ground. When they are installed as middle protection, they must be separated from the other protections by at least 10 meter cable or, if this is not possible, by a decoupling inductor ATLINK, in order to achieve ...
... Install in parallel with the Low Voltage supply line, connected to line, neutral and to ground. When they are installed as middle protection, they must be separated from the other protections by at least 10 meter cable or, if this is not possible, by a decoupling inductor ATLINK, in order to achieve ...
BD8179MUV
... Perform setting so that the voltage is within the allowable ripple voltage range. For the drop voltage during sudden load change; VDR, please perform the rough calculation by the following equation. ⊿I VDR = 10 us [V] Co However, 10 µs is the rough calculation value of the DC/DC response speed. Pl ...
... Perform setting so that the voltage is within the allowable ripple voltage range. For the drop voltage during sudden load change; VDR, please perform the rough calculation by the following equation. ⊿I VDR = 10 us [V] Co However, 10 µs is the rough calculation value of the DC/DC response speed. Pl ...
Understanding Boost Power Stages in Switchmode Power Supplies
... The three basic switching power supply topologies in common use are the buck, boost, and buck-boost. These topologies are non-isolated, i.e., the input and output voltages share a common ground. There are however, isolated derivations of these non-isolated topologies. The power supply topology refer ...
... The three basic switching power supply topologies in common use are the buck, boost, and buck-boost. These topologies are non-isolated, i.e., the input and output voltages share a common ground. There are however, isolated derivations of these non-isolated topologies. The power supply topology refer ...
BWR Models
... The wide input voltage ranges of these A-Series duals (4.7-7.25V for "D5A" models, 9-18V for "D12A" models and 18-75V for "D48A" models) make them excellent candidates for battery-powered systems or for distributed power architectures. Their ±5, ±12 or ±15 Volt outputs cover virtually all standard a ...
... The wide input voltage ranges of these A-Series duals (4.7-7.25V for "D5A" models, 9-18V for "D12A" models and 18-75V for "D48A" models) make them excellent candidates for battery-powered systems or for distributed power architectures. Their ±5, ±12 or ±15 Volt outputs cover virtually all standard a ...
M4300-PM - Panamax!
... monitors the incoming power as displayed on the digital voltmeter. In case of an undervoltage or an overvoltage, a flashing lightning bolt will be displayed in red in the voltmeter, and power to the connected equipment is automatically turned off if either of these conditions is detected. When voltag ...
... monitors the incoming power as displayed on the digital voltmeter. In case of an undervoltage or an overvoltage, a flashing lightning bolt will be displayed in red in the voltmeter, and power to the connected equipment is automatically turned off if either of these conditions is detected. When voltag ...
Lab 1 - UniMAP Portal
... magnetic field. Ferromagnetic cores are commonly used to provide tight magnetic coupling and high flux densities. Single-phase transformers are widely used in low power electronic or control circuits to isolate one circuit from another. They are also used as instrument transformers to measure voltag ...
... magnetic field. Ferromagnetic cores are commonly used to provide tight magnetic coupling and high flux densities. Single-phase transformers are widely used in low power electronic or control circuits to isolate one circuit from another. They are also used as instrument transformers to measure voltag ...
DG412/883, DG413/883 Datasheet
... single-ended from +5V to +34V, or split from ±5V to ±20V. The four switches are bilateral, equally matched for AC or bidirectional signals. The ON-resistance variation with analog signals is quite low over a ±15V analog input range. All switches in the DG412/883 use positive logic (i.e. a logic “1” ...
... single-ended from +5V to +34V, or split from ±5V to ±20V. The four switches are bilateral, equally matched for AC or bidirectional signals. The ON-resistance variation with analog signals is quite low over a ±15V analog input range. All switches in the DG412/883 use positive logic (i.e. a logic “1” ...
DC786 - LTC4260CGN Evaluation Kit Quick Start Guide
... Space is provided for up to three 2010 surface mount sense resistors, and a TO-247 (TO-3P) MOSFET. This allows modification of the board for higher current applications. There is more copper between +48V INPUT and +48V/5A OUTPUT than the turrets and a TO-247 can handle. The limitation is at the sour ...
... Space is provided for up to three 2010 surface mount sense resistors, and a TO-247 (TO-3P) MOSFET. This allows modification of the board for higher current applications. There is more copper between +48V INPUT and +48V/5A OUTPUT than the turrets and a TO-247 can handle. The limitation is at the sour ...
User Manual Rev. 01a
... Press on [SEL] button: Select parameter to be adjusted. The selected parameter will be highlighted. Press on [+] or [-] button: Adjust the parameter selected by [SEL] button. Press on [OK] button: Freeze waveform refresh (entering HOLD state). Press on it again will de-freeze. Change [CPL] switch: S ...
... Press on [SEL] button: Select parameter to be adjusted. The selected parameter will be highlighted. Press on [+] or [-] button: Adjust the parameter selected by [SEL] button. Press on [OK] button: Freeze waveform refresh (entering HOLD state). Press on it again will de-freeze. Change [CPL] switch: S ...
Gyro precessing system
... latitude correction is determined by the angular momen tum of the gyro rotor. If the rotor is driven by a syn 35 may be used to obtain the required characteristic. The resonant frequency of the L-C series combination should chronous motor the speed of the rotor varies linearly fall either below the ...
... latitude correction is determined by the angular momen tum of the gyro rotor. If the rotor is driven by a syn 35 may be used to obtain the required characteristic. The resonant frequency of the L-C series combination should chronous motor the speed of the rotor varies linearly fall either below the ...
MTY25N60E Power MOSFET 25 Amps, 600 Volts
... specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. SCILLC does not convey any license under its patent rights nor the right ...
... specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. SCILLC does not convey any license under its patent rights nor the right ...
International Electrical Engineering Journal (IEEJ) Vol. 5 (2014) No.12, pp. 1649-1654
... and economic measures can be identified as following [5] 1) Lightning and Surge Arrester: Arrester is designed for lightning protection of transformers, but is not limited to sufficient voltage limiting for protecting sensitive electronic control circuits from voltage surges. 2) Thyristor Based Stat ...
... and economic measures can be identified as following [5] 1) Lightning and Surge Arrester: Arrester is designed for lightning protection of transformers, but is not limited to sufficient voltage limiting for protecting sensitive electronic control circuits from voltage surges. 2) Thyristor Based Stat ...
5B30 数据手册DataSheet 下载
... stable gain. At the amplifier input, a stable, laser-trimmed zeroscale input voltage is subtracted from the input signal to set the zero scale value. For user convenience, the zero can be optionally factory-set to meet custom needs. This allows suppression of a zero-scale input value many times larg ...
... stable gain. At the amplifier input, a stable, laser-trimmed zeroscale input voltage is subtracted from the input signal to set the zero scale value. For user convenience, the zero can be optionally factory-set to meet custom needs. This allows suppression of a zero-scale input value many times larg ...
Buck converter
A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.