• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Lecture 4 revised 1/10 How do neurons transmit information over
Lecture 4 revised 1/10 How do neurons transmit information over

... Change voltage that clamp to, see how much current flows, fig. 3.2. This gives a clue as to which ions likely to be responsible for the currents. See how current amplitude changes with voltage. Recall Nernst equation. If ion conc's stay the same during a voltage clamp expt (they will for a while), t ...
ACS715 - Pololu
ACS715 - Pololu

Radar Failure at 12000 Feet Not Optional
Radar Failure at 12000 Feet Not Optional

Asymmetric SPWM used in inverter grid connected
Asymmetric SPWM used in inverter grid connected

Errors and Warnings in WindMil
Errors and Warnings in WindMil

... invalid information, or incorrect setup of something within the model required for the current task •  The Errors and Warnings attempt to give the end user enough information to correctly identify and fix any issues with a model or its setup •  This will go through and cover many of the common E&W t ...
Design of Microcontroller-Based Automatic School Bell
Design of Microcontroller-Based Automatic School Bell

... become a short or an open circuit. When a transistor is used as a switch it must be either OFF or fully ON. In the fully ON state, the voltage VCE across the transistor is almost zero and the transistor is said to be saturated because it cannot pass any more collector current IC. The output device s ...
Evaluates:  MAX1501 MAX1501 Evaluation Kit General Description Features
Evaluates: MAX1501 MAX1501 Evaluation Kit General Description Features

... stage where it increases the charging current by 10% steps every 20ms until the charger reaches 100% fastcharge current programmed by resistor R1. During precharge and fast charge, the red LED is on and the green LED is off. As the battery voltage approaches the 4.5V user-selected regulation voltage ...
Document
Document

Schottky diode I-V Characteristics
Schottky diode I-V Characteristics

... • This is another reason why Schottky diodes are useful in switch-mode power converters; the high speed of the diode means that the circuit can operate at frequencies in the range 200 kHz to 2 MHz, allowing the use of small inductors and capacitors with greater efficiency than would be possible wit ...
cc196880ad09e14
cc196880ad09e14

... converter part on it`s terminals in order not to have ripples and it feed the inverter part. ...
MAX256 3W Primary-Side Transformer H-Bridge Driver for Isolated Supplies General Description
MAX256 3W Primary-Side Transformer H-Bridge Driver for Isolated Supplies General Description

... The MAX256 is an integrated primary-side controller and H-bridge driver for isolated power-supply circuits. The device contains an on-board oscillator, protection circuitry, and internal FET drivers to provide up to 3W of power to the primary winding of a transformer. The MAX256 can be operated usin ...
Current transducer LF 310-S/SP16 I = 300 A
Current transducer LF 310-S/SP16 I = 300 A

... ●● USR indicates investigation to the Standard for Industrial Control Equipment UL 508. ●● CNR indicates investigation to the Canadian standard for Industrial Control Equipment CSA C22.2 No. 14-13 Conditions of acceptability When installed in the end-use equipment, with primary feedthrough potential ...
VT6T12
VT6T12

Wideband vibration energy harvester with high permeability magnetic material Sun
Wideband vibration energy harvester with high permeability magnetic material Sun

... A vibration energy harvester based on a high permeability cantilever beam was demonstrated, which overcomes the limitation of the existing approaches in output power and working bandwidth. Magnetostatic coupling between the vibrating highly permeable beam and bias magnetic field leads to maximized f ...
Experiment FT2
Experiment FT2

Recapturing Lost Space from Mechanical/Thermal Restrictions
Recapturing Lost Space from Mechanical/Thermal Restrictions

... (such as management or support), the end result is the same; it cannot be used. Until now. GE Critical Power discovered how to fill the void. We absorb content or circuitry in order to reclaim that wasted space. We’ve looked at the functionality of our power supply to see how our designs can enable ...
Integrated D-STATCOM with Supercapacitor Used in IEEE Industrial Distribution System Amin Nazarloo
Integrated D-STATCOM with Supercapacitor Used in IEEE Industrial Distribution System Amin Nazarloo

... From 1988, custom power is introduced as a solution to power quality problems. D-STATCOM is one of the custom power devices, which locate shunt in network and applied to mitigate voltage sag and voltage swell [2-4]. The D-STATCOM has emerged as a promising device to provide not only for voltage sag ...
Simplified Harmonic Model for Full Wave Diode Rectifier Circuits
Simplified Harmonic Model for Full Wave Diode Rectifier Circuits

... by a fixed harmonic current source at each iteration. Ref. [5] proposes a harmonic Norton-equivalent circuit model which is developed to represent the converters of HVDC links under both unbalanced and distorted input conditions. In the time domain, a converter can be expressed as a set of different ...
ATE Contact Test thru analog Switch - IC
ATE Contact Test thru analog Switch - IC

... – Higher ‘ON’ resistance – Pose problem in doing ATE contact test due to their own clamp diodes – Need extra ATE supplies to power them ...
LAB - ECE233
LAB - ECE233

... simplified circuit diagrams of a more complex circuit. When the some basic operations are performed (like open circuit and short circuit), the complex circuit turns into simplified one with same characteristics between the selected terminal nodes. The complex circuit and the simplified circuit are e ...
Series-Parallel DC Circuits - benchmark
Series-Parallel DC Circuits - benchmark

AD629 数据手册DataSheet 下载
AD629 数据手册DataSheet 下载

... lines of mixed-signal converters should also be connected to the analog ground plane. Typically, analog and digital grounds should be separated; however, it is also a requirement to minimize the voltage difference between digital and analog grounds on a converter, to keep them as small as possible ( ...
MAX14606/MAX14607 Overvoltage Protectors with Reverse Bias
MAX14606/MAX14607 Overvoltage Protectors with Reverse Bias

LTC3405A-1.5/LTC3405A-1.8 - 1.5V, 1.8V, 1.5MHz, 300mA
LTC3405A-1.5/LTC3405A-1.8 - 1.5V, 1.8V, 1.5MHz, 300mA

Table of Contents
Table of Contents

... of hardware, firmware, and software that allows you to analyze the frequency content of commercial power from 3,000 Hz to 100,000 Hz. These are frequencies above the range of conventional power harmonics. Nevertheless, frequency content in this region can have important impacts on power systems. Sin ...
< 1 ... 1074 1075 1076 1077 1078 1079 1080 1081 1082 ... 1789 >

Buck converter



A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report