• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Logic Design 10CS33
Logic Design 10CS33

... HDL is a language that describes the hardware of digital systems in a textual form. It resembles a programming language, but is specifically oriented to describing hardware structures and behaviors. The main difference with the traditional programming languages is HDL’s representation of extensive p ...
Passive Intermodulation Distortion in Connectors, Cable and
Passive Intermodulation Distortion in Connectors, Cable and

... In general, for connectors and cable assemblies, PIM is not frequency dependent. However, there has been some discussion that testing a cable at different frequencies might yield different results due to the skin depth. For example, the current density at 1800 Mhz would be twice as high as at 900 Mh ...
Understanding Open Loop Gain of the PGA900
Understanding Open Loop Gain of the PGA900

... The PGA900 AOL curve is shaped by a low-frequency dominant pole, a midfrequency pole-zero pair, an additional zero, and a high-frequency triple pole. The complete PGA900 AOL curve is shown in Figure 1 and defined in Equation 1. The typical magnitude and phase response of the AOL curve changes due to ...
A Current Folded Down Conversion Mixer in 0.18µ CMOS Vincent
A Current Folded Down Conversion Mixer in 0.18µ CMOS Vincent

... Although mixers are based on a fundamental non-linear principle, it is important that the mixer must also be able to amplify a range of incoming signals in a linear fashion. A commonly used measure of linearity is the third order intercept (IP3) point. This measure describes the real-world scenario ...
Little Box Challenge - LED lighting, LEDs, power
Little Box Challenge - LED lighting, LEDs, power

... required for a two-level topology. Multiple devices are series-connected in order to achieve the required blocking voltage and to meet output THD requirements by creating a stepped sinusoidal output voltage. For this 240VAC output application, multilevel topologies are required if you are considerin ...
FREQUENCY DIVIDERS DESIGN FOR MULTI
FREQUENCY DIVIDERS DESIGN FOR MULTI

... view, the technology improvement created a new space into the market for new possible applications, and the phenomenon can be seen as “technology driven”. Under another perspective, the need for high-speed and flexible communication systems, can be seen as something required by the every day growing ...
as a PDF
as a PDF

... breakdown between the electrodes. In many applications, however, the drive electronics provide a tighter constraint on the voltage available for actuation. The actuator must provide some specified deflection range, often while maintaining a minimum actuator speed or resonant frequency. In many cases, ...
ISO Rules Part 500 Facilities Division 502 Technical Requirements
ISO Rules Part 500 Facilities Division 502 Technical Requirements

... 12(1) A current transformer used in a protection system must be either magnetic or optical, and must not be the limiting element in the transmission facility’s rating. (2) The maximum available current transformer ratio must be sized for the ultimate fault level of the facility as set out in the fun ...
TRS3221E 数据资料 dataSheet 下载
TRS3221E 数据资料 dataSheet 下载

... connector. The charge pump and four small external capacitors allow operation from a single 3-V to 5.5-V supply. These devices operate at data signaling rates up to 250 kbit/s and a maximum of 30-V/μs driver output slew rate. Flexible control options for power management are available when the seria ...
Expanded Linecard - Automation Integrated
Expanded Linecard - Automation Integrated

... to reduce installation time and provide plumbing flexibility. The A/WPR accurately measures wet media pressures in a variety of applications. Commonly used for monitoring pumps, these devices are also idea for measuring pressure across filters, heat exchangers and compressors. This product’s enclosu ...
Document
Document

... – Must select 16 output bits from the 128 columns – Requires 16 8:1 column multiplexers ...
By Ron Bertrand VK2DQ
By Ron Bertrand VK2DQ

... So theoretically, our OCF antenna will become slightly directional towards the longer end. However, due to other reflections, this may not be at all obvious to the user. Essentially an OCF is no better in performance than the centre-fed dipole. The advantage of the OCF is _? operation on the even ha ...
Noise Measurement Post Amp
Noise Measurement Post Amp

Wireless Temperature and/or Humidity System
Wireless Temperature and/or Humidity System

ISO Rules Part 500 Facilities Division 502 Technical Requirements
ISO Rules Part 500 Facilities Division 502 Technical Requirements

... facility as set out in the functional specification. (3) A current transformer used in a protection system must meet the two point five (2.5L) low internal secondary impedance accuracy requirement as set out in CAN/CSA-C60044-1:07, Instrument transformer – Part 1: Current transformers, Table 1B, or ...
Reduction of Switching Over Voltages in HV Transmission Line
Reduction of Switching Over Voltages in HV Transmission Line

A 16-GHz Ultra-High-Speed Si–SiGe HBT Comparator , Student Member, IEEE,
A 16-GHz Ultra-High-Speed Si–SiGe HBT Comparator , Student Member, IEEE,

TN-41-13: DDR3 Point-to-Point Design Support
TN-41-13: DDR3 Point-to-Point Design Support

... TN-41-13: DDR3 Point-to-Point Design Support DDR3 Layout and Design Considerations quarter of the ball grid (see Decoupling Placement Recommendations Figure 3 (page 9)). Place these capacitors as close to the device as practical with the vias located to the device side of the capacitor. For these a ...
Fault Location Of Overhead Transmission Line.pdf
Fault Location Of Overhead Transmission Line.pdf

... and the reflected travelling wave is detected with time domain reflectometery (TDR). The fault location is then determined by timing analysis of the travelling wave. As the faulted signal obtained at the end of the transmission line is highly mingled with noise, some modern signal processing techniq ...
A sound card - E
A sound card - E

PowerFlex 70 Adjustable Frequency AC Drive Installation Instructions
PowerFlex 70 Adjustable Frequency AC Drive Installation Instructions

ppt - Belle II
ppt - Belle II

... » The chip works fine and has adequate speed for Belle II operation. »- Another prototype with HV transistors has been designed and tested. »- The irradiation of the chip still has to be done but the basic and most critical part (highvoltage NMOS) has been irradiated up to 600 KRad and no damage has ...
DESIGN AND IMPLEMENTATION OF COMPARATOR FOR SIGMA-DELTA MODULATOR Noor Aizad
DESIGN AND IMPLEMENTATION OF COMPARATOR FOR SIGMA-DELTA MODULATOR Noor Aizad

... of the comparator is to compare a signal with a reference signal and produce an output depending on whether the input signal is greater or smaller than reference. Many architectures for comparators exist for various purposes. In this thesis, Latched comparator architecture is used for sigma delta mo ...
NoorShahidaJamoshidMFKE2008 DU
NoorShahidaJamoshidMFKE2008 DU

Application Note Evaluation Board 3kW dual phase LLC
Application Note Evaluation Board 3kW dual phase LLC

... is getting rid of the generated heat, especially at the full load. A very powerful fan can help, but there may be a lot of side effects, like the acoustic noise or the generated vibration, which may not be tolerated by other system components, e.g. hard disk drives in computing applications. And in ...
< 1 ... 8 9 10 11 12 13 14 15 16 ... 174 >

Transmission line loudspeaker

A transmission line loudspeaker is a loudspeaker enclosure design (topology) that uses an acoustic transmission line within the cabinet, compared to the simpler enclosures used by sealed (closed) or ported (bass reflex) designs. Instead of reverberating in a fairly simple damped enclosure, sound from the back of the bass speaker is directed into a long (generally folded) damped pathway within the speaker enclosure, which allows far greater control and use of speaker energy, and the resulting sound.Inside a transmission line loudspeaker, is a (usually folded) pathway into which the sound is directed. The pathway is often covered with varying types and depths of absorbent material, may vary in size or taper, and may be open or closed at its far end. Used correctly, such a design ensures that undesired resonances and energies, which would otherwise cause undesirable auditory effects, are instead selectively absorbed or reduced (""damped"") due to the effects of the duct, or alternatively only emerge from the open end in phase with the sound radiated from the front of the driver, enhancing the output level (""sensitivity"") at low frequencies. The transmission line acts as an acoustic waveguide, and the padding both reduces reflection and resonance, and also slows the speed of sound within the cabinet to allow for better tuning.Transmission line loudspeakers designs are more complex to implement, making mass production difficult, but their advantages have led to acclaim for a number of manufacturers such as IMF, TDL, PMC, KVART & BØLGE and the like. As a rule, transmission line speakers tend to have exceptionally high fidelity low frequency response far below that of a typical speaker or subwoofer, into the infrasonic (British company TDL's studio monitor range from the 1990s quoted their frequency responses as starting from as low as 7 Hz depending upon model) at sensitivity 96 dB, without need for a separate enclosure or driver. Acoustically, TL speakers roll off slower at low frequencies and provide better driver control than standard reflex cabinet designs, are less sensitive to positioning, and tend to create a very spacious soundstage. Modern TL speakers were described in a 2000 review as ""match[ing] reflex cabinet designs in every respect, but with an extra octave of bass, lower LF distortion and a frequency balance which is more independent of listening level"".Although more complex to design and tune, and not as easy to analyze and calculate as other designs, the transmission line design is valued by several smaller manufacturers, as it avoids many of the major disadvantages of other loudspeaker designs. In particular, the basic parameters and equations describing sealed and reflex designs are fairly well understood, the range of options involved in a transmission line design mean that the general design can be somewhat calculated but final transmission line tuning requires considerable attention and is less easy to automate.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report