• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Mathematical Basis of Sliding Mode Control of an Uninterruptible
Mathematical Basis of Sliding Mode Control of an Uninterruptible

... fast dynamic response. 3) The steady-state error between the sinusoidal reference and the load regulation must be zero. To achieve these, the Proportional Integral (PI) controller is usually used [10]. However, when the system using PI controller under the case of a variable load rather than the nom ...
AN2372
AN2372

... The power of ST7MC to control BLDC motors with trapezoidal flux distribution, in 6 step mode, is well known. In addition to this, ST7MC is also capable of delivering three phase sinusoidal complementary PWMs with programmable dead time insertion to control a twolevel three-phase inverter that can dr ...
A lot thanks go to Head of Computer Department Dr. Luai Malhis
A lot thanks go to Head of Computer Department Dr. Luai Malhis

... quad-copter, pictured in Figure 2.2, was developed in secrecy at McCook Field, predecessor to Wright-Patterson Air Force Base, Ohio, until its first flight on December 18th, 1922. In addition to the four main rotors, two additional propellers were used for directional control and two more situated a ...
optimal real-time voltage control with an
optimal real-time voltage control with an

... reactive supply to this portion of the grid. Controlling four LTC transformers would demonstrate how the technique would work when applied to the whole system. Initial testing of the OPF calculations and manual adjustment of the LTC taps several times a day to simulate what would happen when the Co ...
Measurement & Control for the AC Power Industry
Measurement & Control for the AC Power Industry

4100SM Installation Instructions
4100SM Installation Instructions

fdcio181-2-en
fdcio181-2-en

... The error behavior defines the position of the output through controller or configuration tools in case of an error : ‒ Off: Output remains in the same position as before the error ‒ Activation: Output is activated in case of an error ‒ Deactivation: Output is deactivated in case of an error The con ...
AC Drives Selection
AC Drives Selection

SB0800 Octal Valves and Pump Controller System on Chip
SB0800 Octal Valves and Pump Controller System on Chip

... Freescale, the Freescale logo and QorlQ are trademarks of Freescale Semiconductor, Inc., Reg. U.S. Pat. & Tm. Off. SMARTMOS is a trademark of Freescale Semiconductor, Inc. All other product or service names are the property of their ...
UNIVERSAL MOTOR - Home
UNIVERSAL MOTOR - Home

... fast dynamic response to load changes www.technologyfutuare.com ...
Heater Controls & Components
Heater Controls & Components

... on the bottom of the drawing, as you would normally hold it, but the example on the bottom has it’s reference pointer pointing to the right, both are outputs. The top right drawing section has a reference pointer coming in from the top, this indicates an input and shows where the input is coming fro ...
Limitorque® Accutronix MX Protection, Control and Monitoring
Limitorque® Accutronix MX Protection, Control and Monitoring

Arroyo Product Catalog
Arroyo Product Catalog

... The 6310-QCL and 6340-QCL Controllers provide a few key capabilities that optimize the controller for QCL application. Most importantly, the driver offers the higher compliance voltages typical of QCL lasers. In addition, wave number tables can ...
Automatic Voltage Control
Automatic Voltage Control

... the field winding for a synchronous machine or changing the firing angle of inverter based equipment. The aforementioned methods of controlling voltage have been commercially available for both types of equipment are performed automatically on a continual basis without operator intervention provided ...
Glossary of Terms
Glossary of Terms

... both) transducer is used to generate correction signals by comparison to desired parameters. Critical Damping A system is critically damped when the response to a step change in desired velocity or position is achieved in the minimum possible time with little or no overshoot. Crossover Frequency The ...
UC16RL4 Raise-Lower Module - Energi
UC16RL4 Raise-Lower Module - Energi

PDF
PDF

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) ISSN: 2278-1676
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) ISSN: 2278-1676

... dynamic interactions is remarkably expanded. Therefore, robust suppression of grid disturbances is one of the important properties that should be found in the current controller of an inverter-based DGunit. 3) High bandwidth current control performance. This feature is essential to maximize the dist ...
Speeds & Torques in DC Permanent Magnet Motors
Speeds & Torques in DC Permanent Magnet Motors

... As duty cycle decreases, motor slows, causing the motor’s EMF to drop, and the peak current to rise. ...
User Manual
User Manual

... Balanced lines are made specifically for reducing audio interference and noise rejection.  The rule of thumb says, the longer the cable, the morenoiseyouraudiosignalislikelytoencounter.Youraudiocableactsasanantennaandhastheabilitytopickupneighboringfreq ...
AC Induction Motor Control
AC Induction Motor Control

... control of motor torque and magnetic flux. The control is based on the transformation of current/ voltage coordinates from stationary to rotation that makes the control similar to DC machine control. The control incorporates fast torque/ flux current control loops and slower speed/position control l ...
700 Series AC Dielectric Test Sets  High Voltage AC Test Systems FEATURES
700 Series AC Dielectric Test Sets High Voltage AC Test Systems FEATURES

... usually performed at lower levels than AC withstand levels. If PD testing is required it is necessary to know the PD sensitivity level for the test and the test voltage. Specifying too high a PD test voltage or unnecessarily low PD free rating for the system inflates the cost of a test system. ...
Automatic Speed Controller of a DC Motor Using
Automatic Speed Controller of a DC Motor Using

... been used for testing the controller. Close loop control has been applied by using appropriate speed encoder. The controller functions as a DC chopper and PWM signal is produced by an Arduino UNO controller. The nominal input voltage was 200Volt, so igbt switching devices were used. There are over v ...
2 - 3B Scientific
2 - 3B Scientific

... Depending on the sequence of the layers, the transistor may either be termed npn or pnp (Fig. 1). Bipolar transistors are operated as quadripoles in three basic circuits, distinguished by the arrangement of the terminals and called common emitter, common collector and common base. The names indicate ...
Push Button Start handout - OpenSIUC
Push Button Start handout - OpenSIUC

< 1 ... 69 70 71 72 73 74 75 76 77 ... 140 >

Control theory



Control theory is an interdisciplinary branch of engineering and mathematics that deals with the behavior of dynamical systems with inputs, and how their behavior is modified by feedback. The usual objective of control theory is to control a system, often called the plant, so its output follows a desired control signal, called the reference, which may be a fixed or changing value. To do this a controller is designed, which monitors the output and compares it with the reference. The difference between actual and desired output, called the error signal, is applied as feedback to the input of the system, to bring the actual output closer to the reference. Some topics studied in control theory are stability (whether the output will converge to the reference value or oscillate about it), controllability and observability.Extensive use is usually made of a diagrammatic style known as the block diagram. The transfer function, also known as the system function or network function, is a mathematical representation of the relation between the input and output based on the differential equations describing the system.Although a major application of control theory is in control systems engineering, which deals with the design of process control systems for industry, other applications range far beyond this. As the general theory of feedback systems, control theory is useful wherever feedback occurs. A few examples are in physiology, electronics, climate modeling, machine design, ecosystems, navigation, neural networks, predator-prey interaction, gene expression, and production theory.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report