• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Aalborg Universitet Modular Plug’n’Play Control Architectures for Three-phase Inverters in UPS Applications
Aalborg Universitet Modular Plug’n’Play Control Architectures for Three-phase Inverters in UPS Applications

... value of phase k, voltage compensation block transfer function, phase restoration value of voltage phase, phase reference in central controller of phase k (utility phase angle), AC bus voltage phase angle of phase k and phase compensation blocks transfer function respectively. It can be seen that th ...
Optimized Distribution Feeder Protection With Remote and Local
Optimized Distribution Feeder Protection With Remote and Local

S.C., D.M. Otten, T.A. Keim, and D.J. Perreault, “Design and Evaluation of a 42 V Automotive Alternator with Integrated Switched-Mode Rectifier,” 2007 IEEE Vehicle Power and Propulsion Conference , September 2007, pp. 250 – 258
S.C., D.M. Otten, T.A. Keim, and D.J. Perreault, “Design and Evaluation of a 42 V Automotive Alternator with Integrated Switched-Mode Rectifier,” 2007 IEEE Vehicle Power and Propulsion Conference , September 2007, pp. 250 – 258

... we constrain the control to only discrete duty ratios, the load matching condition indicated in (2) and illustrated in Fig. 2 is not achieved precisely across speed. However, in our fourcell design there is sufficient flexibility with four available duty ratios (d = 0, 0.25, 0.5 and 0.75) to make a ...
STABILITY ANALYSIS AND OPTIMAL CONTROL DESIGN FOR AC-DC POWER SYSTEM WITH by
STABILITY ANALYSIS AND OPTIMAL CONTROL DESIGN FOR AC-DC POWER SYSTEM WITH by

... rectifier - with constant power load (CPL) and proposes an optimal design for the system control. CPLs have been widely seen in power electronic applications. For example, motor drives and DC/AC inverters in advanced automotive systems may behave as CPLs. Due to their negative impedances, CPLs often ...
STRIKER 10 - globalcube.net
STRIKER 10 - globalcube.net

... • If damage has been found or parts are missing, please contact your vendor or our customer support number for further instructions. Introduction • This fixture can operate in five different operating modes: DMX control, sound active, automatic programs, manual setup on the back LCD or in a Master/S ...
AC21168174
AC21168174

... c) Optimal energy compensation. This strategy minimizes the energy transfer between the energy storage and the grid during steady-state operation. Although these are the best well-known control strategies, many efforts are being made to develop new ones to enable better DVR utilization as discussed ...
Water/Sewer/Drainage Electrical Specifications
Water/Sewer/Drainage Electrical Specifications

... All wiring to doors to be bundled with sufficient slack to allow doors to open fully, bundle to twist at door and not bend. ...
Model HU-224/225 - Building Controls Connection Inc
Model HU-224/225 - Building Controls Connection Inc

T401 - T402 Operating Instructions 383E-64618
T401 - T402 Operating Instructions 383E-64618

High Brightness LED Controller using the MC9RS08KA2
High Brightness LED Controller using the MC9RS08KA2

How to Select Automation Accessories for Valves T
How to Select Automation Accessories for Valves T

... designed to withstand the maximum expected internal explosion pressure without damage or excessive distortion and to provide venting for the pressure through channels of such dimensions that gases will be cooled below the ignition temperature before reaching the surrounding atmosphere. Thus the desi ...
FE21982988
FE21982988

... electrical modes of a turbine-generator system, and interareamodes, which may be caused by either high-gain exciters or heavy power transfers across weak tie-lines [1].When present in a power system, this type of oscillation limits the amount of power transfer on the tie-lines between the regions co ...
MAX1801 Digital Camera Step-Up Slave DC-DC Controller General Description
MAX1801 Digital Camera Step-Up Slave DC-DC Controller General Description

... when the internally level-shifted sawtooth waveform voltage rises above the voltage at COMP or when the maximum duty cycle is exceeded. The switch remains off until the beginning of the next cycle. An internal transconductance amplifier establishes an integrated error voltage at COMP, increasing the ...
II. Excitation System
II. Excitation System

... Exciter is the source of electrical power for the field winding of generator and is realized as a separate DC or AC generator. Exciter has its field winding in the stator, and armature winding in the rotor. In case of AC generator, as the rotor rotates, stator DC current induces a three-phase altern ...
Sensorless Control of Doubly-Fed Induction Generators in Variable
Sensorless Control of Doubly-Fed Induction Generators in Variable

... synchronous speed is feasible. Due to their wide use in WTS, the development of advanced and reliable control techniques for DFIGs has received significant attention during the last years [2]. Examples of these control techniques are e.g. vector control, direct torque control, and direct power contr ...
i DEVELOPMENT OF A POWER FACTOR CORRECTION BUCK
i DEVELOPMENT OF A POWER FACTOR CORRECTION BUCK

... software. Fuzzy logic controller has advantages in fast response controlled with higher accuracy. FLC has a potential to improve robustness of DC – DC converter. Based on those related work, the researchers make a great efforts to propose the good to overcome the DC-DC Converter problems. Their appl ...
Aalborg Universitet
Aalborg Universitet

... control may utilize different output characteristic curves reference. The output characteristic can be classified as “slave depending on SoC conditions, as shown in Fig. 3, which droop” between output power and bus frequency in this range. includes two ranges of coordinated control CR1 and CR2. In I ...
Temperature controller for heated/chilled ceiling systems
Temperature controller for heated/chilled ceiling systems

... Account must be taken of the following performance data, including starting currents: – Wire sizing values for room temperature controllers: 3 VA per CRK24-B1 – Wire sizing values for the valve actuators can be obtained from current data sheets and product information (www.belimo.eu) – Other devi ...
Written Specification (word document)
Written Specification (word document)

... (TIM) option. The optional TIM unit shall allow modem communications and touch-tone overrides from any touch-tone phone. The control system shall be multi-tasking and permit up to one TIM for each control panel. Override Operation: Touch-tone interface shall permit the control panel to command preas ...
MAX8664 Low-Cost, Dual-Output, Step-Down Controller with Fast Transient Response General Description
MAX8664 Low-Cost, Dual-Output, Step-Down Controller with Fast Transient Response General Description

... the input voltage on each channel. Total output error is less than ±0.8% over load, line, and temperature. The MAX8664 operates with a constant switching frequency adjustable from 100kHz to 1MHz. Built-in boost diodes reduce external component count. Digital softstart eliminates input inrush current ...
- IEEE Mentor
- IEEE Mentor

... • Part 1: specification of MAC and Upper PHY by 802.15.7 • Part 2: specification of the Lower PHY interface by ????  PHY does not need to be split and both of the above two parts should be specified by 802.15.7.  Even the air interface which can be a part of lighting control such as in forms of vo ...
A Slot Harmonic Detection with an Empirical Formula to Extend the
A Slot Harmonic Detection with an Empirical Formula to Extend the

Chapter 3
Chapter 3

...  Perfect callback: Admit packets into the network from the user only when the network has capacity (bandwidth and buffers) to get the packetTransport ...
Analog Devices Welcomes Hittite Microwave Corporation
Analog Devices Welcomes Hittite Microwave Corporation

... The HMC321LP4 & HMC321LP4E are broadband nonreflective GaAs MESFET SP8T switches in low cost leadless surface mount packages. Covering DC to 8 GHz, this switch offers high isolation and low insertion loss. This switch also includes an on board binary decoder circuit which reduces the required logic ...
PDF
PDF

... in relation to infectious diseases. In relation to deterministic models, it was Hamer (1906 in Bailey 1975) who considered that the course of an. epidemic depends on the number of susceptibles and the contact rate between susceptibles and infectious individuals the basic mathematical assumption of a ...
< 1 ... 31 32 33 34 35 36 37 38 39 ... 140 >

Control theory



Control theory is an interdisciplinary branch of engineering and mathematics that deals with the behavior of dynamical systems with inputs, and how their behavior is modified by feedback. The usual objective of control theory is to control a system, often called the plant, so its output follows a desired control signal, called the reference, which may be a fixed or changing value. To do this a controller is designed, which monitors the output and compares it with the reference. The difference between actual and desired output, called the error signal, is applied as feedback to the input of the system, to bring the actual output closer to the reference. Some topics studied in control theory are stability (whether the output will converge to the reference value or oscillate about it), controllability and observability.Extensive use is usually made of a diagrammatic style known as the block diagram. The transfer function, also known as the system function or network function, is a mathematical representation of the relation between the input and output based on the differential equations describing the system.Although a major application of control theory is in control systems engineering, which deals with the design of process control systems for industry, other applications range far beyond this. As the general theory of feedback systems, control theory is useful wherever feedback occurs. A few examples are in physiology, electronics, climate modeling, machine design, ecosystems, navigation, neural networks, predator-prey interaction, gene expression, and production theory.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report