• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
1-axis-controller MC1: Operating instruction
1-axis-controller MC1: Operating instruction

- Enercon Engineering, Inc.
- Enercon Engineering, Inc.

290-25
290-25

... The high quality vacuum interrupters used in VSA20B circuit breakers are manufactured exclusively at Eaton's Cooper Power Systems Switchgear plant. Our vacuum interrupters are used worldwide in the industry’s broadest line of fault protection and switching apparatus, where they have established a pr ...
SmartTrigger Operations Manual TS Digital Power-Tracking Controller
SmartTrigger Operations Manual TS Digital Power-Tracking Controller

... to adjust the vibration intensity of the feeder. 5. Power on indicator - When illuminated, this indicates that the unit is powered on. 6. Photo sensor connector (optional) – The Smart Trigger is normally delivered with this hole covered with a plastic hole plug. A four pin threaded female connector ...
Aalborg Universitet Damping Inter-area Oscillations using Static Synchronous Series Compensator (SSSC)
Aalborg Universitet Damping Inter-area Oscillations using Static Synchronous Series Compensator (SSSC)

... synchronous phase angle. This PI controller is used to keep the DC voltage Vdc constant so that there is no active power input to or output from SSSC, therefore, the result PWM phase angle makes sure that Vc is in quadrature with It and SSSC appears as a reactance. IV. INFLUENCE OF SSSC ON SMALL SIG ...
R 4series 74-84 Three phase digital speed
R 4series 74-84 Three phase digital speed

... stop the motor. This motor can itself sustain stoppage by a mechanical lock. Finally, voltage variations, in particular power cuts, may also cause stoppages to occur. The disappearance of causes of stoppage could cause restarting, dangerous to some machines or installations, in particular those whic ...
ChamberMate - Fireright.Com
ChamberMate - Fireright.Com

... The controller's temperature measuring circuit, the first half of U8 and its associated circuitry, converts the low level thermocouple input to a scaled and compensated high level analog voltage. The sensor, "mj" (measuring junction) is connected to U8-11, the input of this amplifier. C17 provides l ...
Written Specification (word document)
Written Specification (word document)

... commands to insure building integrity. Priorities enable or disable the inputs based on user actuation of overrides. Masks shall permit: On only, Off only and On & Off control for intelligent after hours utilization of the controlled facility based on Time-Of-Day scheduling in the controller. 9. The ...
Discrete-time AC motor control apparatus
Discrete-time AC motor control apparatus

... The Subscript k denotes that the associated value is state estimation observer 11 can be accomplished at a attained at a sampling time (point of time) k, whereas high speed, which is satisfactory with respect to a time the subscript k+ 1 indicates that the value is obtained at constant of the motor. ...
2016-05-13 Reactor Troubleshooting guide rev 2.9
2016-05-13 Reactor Troubleshooting guide rev 2.9

... 0A (zero amps) on the Hose Zone Display. o If the FTS is disconnected or the display shows E04, turn the main disconnect off, then on to clear the alarm, and default the machine into manual current hose heat mode. 0A (zero amps) will show in the actual display with the hose zone off. o When in the t ...
dynamic simulation of a pv-diesel-battery hybrid plant
dynamic simulation of a pv-diesel-battery hybrid plant

... Table 12: Generated energy by the plant components for the simulated day. .............................. 70 Table 13: Maximum frequency deviations of the control strategies for the simulated day. ......... 72 Table 14: Fuel consumption of generator (1) for the simulated day.......................... ...
1 - Introduction to Dimming Concepts
1 - Introduction to Dimming Concepts

... computer software package or other DMX command generator. Up to 32 unit loads may be connected to the same wire run. (Some devices may state that they are a ½ load or ¼ load or a full load. Totaled together, this number should not exceed 32 unit loads). Splitters or repeaters may be used to extend t ...
Design and Experimental Implementation of an Electromagnetic Engine Valve Drive Please share
Design and Experimental Implementation of an Electromagnetic Engine Valve Drive Please share

... these cams is determined by considering a tradeoff between engine speed, power, and torque requirements, as well as vehicle fuel consumption. This optimization results in an engine that is highly efficient only at certain speeds [4]. If instead the engine valves are actuated as a variable function o ...
lesson topic 8.1 synchros and control
lesson topic 8.1 synchros and control

... • Synchros, as stated earlier, are simply variable transformers. They differ from conventional transformers by having one primary winding (the rotor), which may be rotated through 360º and three stationary secondary windings (the stator) spaced 120º apart. It follows that the magnetic field within t ...
Distributed Control of Inverter-Based Power Grids
Distributed Control of Inverter-Based Power Grids

m903 reference headphone amplifier / DAC
m903 reference headphone amplifier / DAC

BX26501512
BX26501512

... Stator flux estimation using dc link voltage and two line currents (voltage model) One desirable feature of direct torque control, or any control method based on stator flux control is to consider usually the stator flux as an estimated quantity using terminal measurements [6]. At first, simple flux ...
Detailed Course Lectures (PowerPoint file)
Detailed Course Lectures (PowerPoint file)

... This class will not require the purchase or use of a traditional text book. I will instead provide internet links to both required and optional reading material. It is the student’s responsibility to keep up with the reading material. I will not be printing this material nor will I be providing down ...
WPON 응용을 위한 고속 CMOS어레이 광트랜스미터
WPON 응용을 위한 고속 CMOS어레이 광트랜스미터

INSTRUCTION MANUAL - Beck Electric Actuators
INSTRUCTION MANUAL - Beck Electric Actuators

... durability. The gear train can withstand accidental stalls of up to four days without failure, and will resume instant response immediately upon removal of the condition (see page 22 for Stall Protection and Annunciation information). Gear modules and motors can be interchanged in the field to alter ...
Contents
Contents

... Charting applications provide year over year comparisons for usage on a daily basis. A simple wizard tool is used to dynamically change date ranges, usage calculations (High/Low/Average), and outside temperature. Results are overlaid in a line graph for easy comparison. In addition, graphical load/d ...
The Control Outcome Calibration Approach for Causal Inference
The Control Outcome Calibration Approach for Causal Inference

... measure of the outcome process. However, outside of this special case, the assumption may not be appropriate if the outcomes are clearly measured on different scales, such as, for example, if the negative control outcome were dichotomous and the primary outcome were continuous. The assumption would ...
FMS6501A 12x9 Video Switch Matrix with Input Clamp, Input Bias
FMS6501A 12x9 Video Switch Matrix with Input Clamp, Input Bias

... clamp rather than a full DC-restore circuit. For video signals with and without sync (Y, CV, R, G, B); the lowest voltage at the output pins is clamped to ~300 mV above ground when the 6dB gain setting is selected. If symmetric AC-coupled input signals are used (Chroma, Pb, Pr, Cb, Cr), the bias cir ...
Performance Analysis of LLC-LC Resonant Converter Fed
Performance Analysis of LLC-LC Resonant Converter Fed

... gain will loosely control the system, while higher values will give stiff values. At this point, the system will probably not converge to the set point. After this, ‘I’ gain can be increased so as to force the system error to zero. A slight increase is sufficient in ‘I’ such that it does not overcom ...
Motor controller guide
Motor controller guide

... voltage is applied in the next command and the speed is re-measured to see if the motor spins at 50% or if more command adjustments are needed. To do this, motor control systems often include some kind of sensor, such as an encoder, that measures how much the motor has rotated. When this information ...
< 1 ... 18 19 20 21 22 23 24 25 26 ... 140 >

Control theory



Control theory is an interdisciplinary branch of engineering and mathematics that deals with the behavior of dynamical systems with inputs, and how their behavior is modified by feedback. The usual objective of control theory is to control a system, often called the plant, so its output follows a desired control signal, called the reference, which may be a fixed or changing value. To do this a controller is designed, which monitors the output and compares it with the reference. The difference between actual and desired output, called the error signal, is applied as feedback to the input of the system, to bring the actual output closer to the reference. Some topics studied in control theory are stability (whether the output will converge to the reference value or oscillate about it), controllability and observability.Extensive use is usually made of a diagrammatic style known as the block diagram. The transfer function, also known as the system function or network function, is a mathematical representation of the relation between the input and output based on the differential equations describing the system.Although a major application of control theory is in control systems engineering, which deals with the design of process control systems for industry, other applications range far beyond this. As the general theory of feedback systems, control theory is useful wherever feedback occurs. A few examples are in physiology, electronics, climate modeling, machine design, ecosystems, navigation, neural networks, predator-prey interaction, gene expression, and production theory.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report