
lectro-static-discharge-basics-by-transforming
... Proper use of personal grounding equipment such as heel grounders or wrist straps Personnel should understand ESD equipment test methods and documentation Understanding of other ESD control methods such as ionization ...
... Proper use of personal grounding equipment such as heel grounders or wrist straps Personnel should understand ESD equipment test methods and documentation Understanding of other ESD control methods such as ionization ...
User Manual V1.03 - Scavenger Transmitter Module STM
... are subject to change without notice. For the latest product specifications, refer to the EnOcean website: http://www.enocean.com. As far as patents or other rights of third parties are concerned, liability is only assumed for modules, not for the described applications, processes and circuits. EnOc ...
... are subject to change without notice. For the latest product specifications, refer to the EnOcean website: http://www.enocean.com. As far as patents or other rights of third parties are concerned, liability is only assumed for modules, not for the described applications, processes and circuits. EnOc ...
ADM6821-25 - Analog Devices
... much as 160 μA. Pulsing WDI low-high-low at a low duty cycle reduces the effect of the large input current. When WDI is unconnected, a window comparator disconnects the watchdog timer from the reset output circuitry so that reset is not asserted when the watchdog timer times out. ...
... much as 160 μA. Pulsing WDI low-high-low at a low duty cycle reduces the effect of the large input current. When WDI is unconnected, a window comparator disconnects the watchdog timer from the reset output circuitry so that reset is not asserted when the watchdog timer times out. ...
Service Manual - Fluke Calibration
... substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption. Fluke authorized resellers shall extend this warranty on new and unused p ...
... substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption. Fluke authorized resellers shall extend this warranty on new and unused p ...
ADM6821 数据手册DataSheet 下载
... much as 160 μA. Pulsing WDI low-high-low at a low duty cycle reduces the effect of the large input current. When WDI is unconnected, a window comparator disconnects the watchdog timer from the reset output circuitry so that reset is not asserted when the watchdog timer times out. ...
... much as 160 μA. Pulsing WDI low-high-low at a low duty cycle reduces the effect of the large input current. When WDI is unconnected, a window comparator disconnects the watchdog timer from the reset output circuitry so that reset is not asserted when the watchdog timer times out. ...
An Area-Efficient Carry Select Adder Design By Using 180 Nm
... adder with 4, 8, 16, and 32-bit respectively in tsmc 0.18um CMOS technology. The power consumption difference between these two designs is small in the case of 4-bit input word length. Since the conventional carry select adder consists of the duplicated adder cells to prepare both the possible outpu ...
... adder with 4, 8, 16, and 32-bit respectively in tsmc 0.18um CMOS technology. The power consumption difference between these two designs is small in the case of 4-bit input word length. Since the conventional carry select adder consists of the duplicated adder cells to prepare both the possible outpu ...
budget ignitions - Telematica Electronics
... MSD was the first company to develop and offer the multiple sparking, capacitive discharge ignition for engines. The line of MSD 6-Series Ignitions are the most popular aftermarket ignitions in the world due to our race-proven performance on the track and our reliability on the street! Most of the 6 ...
... MSD was the first company to develop and offer the multiple sparking, capacitive discharge ignition for engines. The line of MSD 6-Series Ignitions are the most popular aftermarket ignitions in the world due to our race-proven performance on the track and our reliability on the street! Most of the 6 ...
Performance Rating of Positive Displacement Carbon
... valves, suction filters, oil separators, external power source (for Open Drive Refrigerant Compressor), as provided by the manufacturer. This will also include variable capacity controls, electronic or electro-mechanical, as supplied or specified by the manufacturer. ...
... valves, suction filters, oil separators, external power source (for Open Drive Refrigerant Compressor), as provided by the manufacturer. This will also include variable capacity controls, electronic or electro-mechanical, as supplied or specified by the manufacturer. ...
LTM4601/LTM4601-1 - 12A DC/DC uModules with PLL, Output Tracking and Margining
... 3.42mm BGA packages. Operating over an input voltage range of 4.5V to 20V, the LTM4601 supports an output voltage range of 0.6V to 5V as well as output voltage tracking and margining. The high efficiency design delivers 12A continuous current (14A peak). Only bulk input and output capacitors are nee ...
... 3.42mm BGA packages. Operating over an input voltage range of 4.5V to 20V, the LTM4601 supports an output voltage range of 0.6V to 5V as well as output voltage tracking and margining. The high efficiency design delivers 12A continuous current (14A peak). Only bulk input and output capacitors are nee ...
table of contents - 2016 IEEE – ECCE Conference
... Influence of Blade Pass Frequency Vibrations on MCSA-based Rotor Fault Detection of Induction Motors Yonghyun Park, Sang Bin Lee, Myung Jeong, Jose Antonino-Daviu and Mike Teska Stator Insulation Quality Assurance Testing for Appliance Motors with Aluminum Windings Daewoong Choi, Taejune Kang, Sang ...
... Influence of Blade Pass Frequency Vibrations on MCSA-based Rotor Fault Detection of Induction Motors Yonghyun Park, Sang Bin Lee, Myung Jeong, Jose Antonino-Daviu and Mike Teska Stator Insulation Quality Assurance Testing for Appliance Motors with Aluminum Windings Daewoong Choi, Taejune Kang, Sang ...
Chapter 2 - Automation Direct
... • The Instruction List window displays all available CLICK PLC instructions, allows you to drag and drop the instruction into your ladder logic program, and then enter any values and/or parameters required for the particular instruction. • You can add Subroutine and Interrupt programs separately f ...
... • The Instruction List window displays all available CLICK PLC instructions, allows you to drag and drop the instruction into your ladder logic program, and then enter any values and/or parameters required for the particular instruction. • You can add Subroutine and Interrupt programs separately f ...
Error Code Troubleshooting Guide
... hot and neutral wires can be verified by measuring each in reference to AC (green wire) ground. 3. Even though unlikely, the AC line frequency could actually be out of acceptable limits. This is more likely to occur in countries where AC power systems may not be well developed and controlled. There ...
... hot and neutral wires can be verified by measuring each in reference to AC (green wire) ground. 3. Even though unlikely, the AC line frequency could actually be out of acceptable limits. This is more likely to occur in countries where AC power systems may not be well developed and controlled. There ...
2.5 V/3.3 V, 10-Bit, 2-Port Level Translating, Bus Switch ADG3246
... VCC = 3 V, SEL = VCC, VA = 0 V, IBA = 8 mA VCC = 3 V, SEL = VCC, VA = 1.7 V, IBA = 8 mA VCC = 2.3 V, SEL = VCC, VA = 0 V, IBA = 8 mA VCC = 2.3 V, SEL = VCC, VA = 1 V, IBA = 8 mA VCC = 3 V, SEL = 0 V, VA = 0 V, IBA = 8 mA VCC = 3 V, SEL = 0 V, VA = 1 V, IBA = 8 mA VCC = 3 V, SEL = VCC, VA = 0 V, IBA ...
... VCC = 3 V, SEL = VCC, VA = 0 V, IBA = 8 mA VCC = 3 V, SEL = VCC, VA = 1.7 V, IBA = 8 mA VCC = 2.3 V, SEL = VCC, VA = 0 V, IBA = 8 mA VCC = 2.3 V, SEL = VCC, VA = 1 V, IBA = 8 mA VCC = 3 V, SEL = 0 V, VA = 0 V, IBA = 8 mA VCC = 3 V, SEL = 0 V, VA = 1 V, IBA = 8 mA VCC = 3 V, SEL = VCC, VA = 0 V, IBA ...
morphagene-manual.
... The Morphagene comes with a blank microSD card for storing sounds. No sounds are included with this card. You don’t need somebody telling you what sounds are approved for use. The world of sound is larger than we could possibly imply with presets. But this does mean you will need to take some action ...
... The Morphagene comes with a blank microSD card for storing sounds. No sounds are included with this card. You don’t need somebody telling you what sounds are approved for use. The world of sound is larger than we could possibly imply with presets. But this does mean you will need to take some action ...
User Manual S811+ Soft Starter Effective November 2012 Supersedes July 2012
... plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this ...
... plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this ...
ADG3245 数据手册DataSheet 下载
... Quiescent Power Supply Current. This current represents the leakage current between the VCC and ground pins. It is measured when all control inputs are at a logic HIGH or LOW level and the switches are OFF. Extra power supply current component for the BE control input when the input is not driven at ...
... Quiescent Power Supply Current. This current represents the leakage current between the VCC and ground pins. It is measured when all control inputs are at a logic HIGH or LOW level and the switches are OFF. Extra power supply current component for the BE control input when the input is not driven at ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.