• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Negative Rail Input, Rail-to-Rail Out, Precision, 850
Negative Rail Input, Rail-to-Rail Out, Precision, 850

... Electrical Characteristics: Vs+ – Vs– = 5 V (continued) At TA ≈ 25°C, Vocm = open (defaults midsupply), VOUT = 2 VPP, Rf = 402 Ω, Rload = 499 Ω, 50-Ω input match, G = 2 V/V, single-ended input, differential output, and PD = +Vs, unless otherwise noted. See Figure 61 for an ac-coupled gain of a 2-V/V ...
Solid-state Timer - OMRON Industrial Automation
Solid-state Timer - OMRON Industrial Automation

2-Wire HID Relays Technical WR-6161, WR-6172
2-Wire HID Relays Technical WR-6161, WR-6172

ZAPI ACE-2 manual
ZAPI ACE-2 manual

AD9601 10-Bit, 200 MSPS/250 MSPS 1.8 V Analog-to
AD9601 10-Bit, 200 MSPS/250 MSPS 1.8 V Analog-to

MAX9324 One-to-Five LVPECL/LVCMOS Output Clock and Data Driver General Description
MAX9324 One-to-Five LVPECL/LVCMOS Output Clock and Data Driver General Description

... Measurements are made with the device in thermal equilibrium. Current into a pin is defined as positive. Current out of a pin is defined as negative. DC parameters are production tested at TA = +25°C and guaranteed by design over the full operating temperature range. All pins open except VCC and GND ...


... PEMFCs are the most popular type of Fuel Cells (F Cs) and traditionally use hydrogen as the fuel. One FC problem is its relative slow dynamics caused by the time constant of the hydrogen and oxygen supply systems that can be in the range of several seconds. In this sense, supercapacitors (SCs) respo ...
ALARM STAGE [1] @
ALARM STAGE [1] @

I-Tech HD Series
I-Tech HD Series

... Obtaining Other Language Versions: To obtain information in another language about the use of this product, please contact your local Crown Distributor. If you need assistance locating your local distributor, please contact Crown at 574-294-8000. This manual does not include all of the details of de ...
Design_Hardware - Network and Systems Laboratory
Design_Hardware - Network and Systems Laboratory

Chapter 4 Electrical Characteristics of CMOS
Chapter 4 Electrical Characteristics of CMOS

LTM4616 - Dual 8A per Channel Low VIN DC/DC uModule
LTM4616 - Dual 8A per Channel Low VIN DC/DC uModule

... The LTM®4616 is a complete dual 2-phase 8A per channel switch mode DC/DC power regulator system in a 15mm × 15mm surface mount LGA or BGA package. Included in the package are the switching controller, power FETs, inductor and all support components. Operating from an input voltage range of 2.7V to 5 ...
Circuit Design for Realization of a 16 bit 1MS/s Successive
Circuit Design for Realization of a 16 bit 1MS/s Successive

... The overall goal of this work is to design a novel successive approximation converter for use with the split ADC algorithm. The split ADC concept has proven successful in calibrating a cyclic analog to digital converter, and will now be applied to a SAR converter. This thesis focuses specifically on ...
UM0486
UM0486

... windings, a sinusoidally distributed air gap flux generating the rotor current is produced. The interaction of the sinusoidally distributed air gap flux and induced rotor currents produces a torque on the rotor. The mechanical angular velocity of the rotor is lower then the angular velocity of the f ...
MCQ-EDC-unit-2 - WordPress.com
MCQ-EDC-unit-2 - WordPress.com

... C. the sum of the two input voltages. D.the difference of the two input voltages. Ans. D ...
How to control and monitor up to 16 via an HM
How to control and monitor up to 16 via an HM

... The only communication parameter that must be changed for each Motor Insight is the Modbus node address. The “Motor 1” button will access the control, configuration, and status pages for the Motor Insight with Modbus serial address 1. The “Motor 2” button will access the control, configuration, and ...
Presentation title here
Presentation title here

... Isolation Boundary to Control Light Output Using Multiple LED Driver ICs • Ensures TRIAC remains in conduction for proper mapping of phase signal. ...
Specification Sheet PDF
Specification Sheet PDF

... Each lumenline reflector requires 1x DMX/RDM or DALI address: a lumenline fixture can contain multiple reflectors, refer to Board and Reflector Layout for details. Consult factory for specific applications. ...
TPA6130A2 - Texas Instruments
TPA6130A2 - Texas Instruments

... Charge pump voltage supply. VDD must be connected to the common VDD voltage supply. Decouple to GND (pin 19 on the QFN) with its own 1 μF capacitor. ...
Document
Document

... Q. CSX soft starters control only two phases, leaving one phase connected to the supply. Does this mean an additional line contactor must be employed in a circuit breaker/CSX motor branch circuit ? A. No. Use of a two phase soft starter does not require an additional line contactor as compared with ...
View / Full Text - International Journal of Science
View / Full Text - International Journal of Science

LM317 - Electronics
LM317 - Electronics

... 1.2V to 37V output range. They are exceptionally easy to use and require only two external resistors to set the output voltage. Further, both line and load regulation are better than standard fixed regulators. Also, the LM117 is packaged in standard transistor packages which are easily mounted and h ...
DAC8532 - Farnell
DAC8532 - Farnell

... range of 2.7V to 5.5V. The device supports a standard 3-wire serial interface capable of operating with input data clock frequencies up to 30MHz for VDD = 5V. The DAC8532 requires an external reference voltage to set the output range of each DAC channel. Also incorporated into the device is a power- ...
Ultra-low-noise large-bandwidth transimpedance amplifier
Ultra-low-noise large-bandwidth transimpedance amplifier

S260-75-1
S260-75-1

... The time delay setting for preferred to alternate source transfer must be long enough to allow discrimination between permanent loss of voltage and temporary loss of voltage due to transient effects or reclosing intervals of backup protective reclosers or breakers. The timedelay required to override ...
< 1 ... 41 42 43 44 45 46 47 48 49 ... 528 >

Control system



A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report