
OPTOTRONIC Technical Guide.
... DC-dimming is a straightforward solution to reduce the thermal load (and brightness) of a LED. For example, reducing the LED’s current from 350 mA down to 250 mA, will reduce the thermal load on the LED accordingly. Varying the current of LED may however have sideeffects on the light output of the L ...
... DC-dimming is a straightforward solution to reduce the thermal load (and brightness) of a LED. For example, reducing the LED’s current from 350 mA down to 250 mA, will reduce the thermal load on the LED accordingly. Varying the current of LED may however have sideeffects on the light output of the L ...
PSoC 4 Programmable Gain Amplifier (PGA_P4)
... Rb. The value of the capacitor is configured automatically (by the component API code) for each gain and power level to achieve guaranteed stability. Reassigning resistor values (directly in registers) without selecting the appropriate feedback capacitor value can result in PGA instability or reduce ...
... Rb. The value of the capacitor is configured automatically (by the component API code) for each gain and power level to achieve guaranteed stability. Reassigning resistor values (directly in registers) without selecting the appropriate feedback capacitor value can result in PGA instability or reduce ...
MF10-P1/MF10-P2 - hegewald
... mm or more. A measured value is displayed. OFF : The reference point is set as the position of the measuring unit at power ON, and the measured value is displayed. The displayed value is the preset value. * After the setting, turning the power OFF then ON, or searching the reference point again, ref ...
... mm or more. A measured value is displayed. OFF : The reference point is set as the position of the measuring unit at power ON, and the measured value is displayed. The displayed value is the preset value. * After the setting, turning the power OFF then ON, or searching the reference point again, ref ...
MAX1617A Remote/Local Temperature Sensor with SMBus Serial Interface ________________General Description
... conversion process has started, either in free-running or single-shot mode. If one of the two channels is not used, the device still performs both measurements, and the user can simply ignore the results of the unused channel. If the remote diode channel is unused, tie DXP to DXN rather than leaving ...
... conversion process has started, either in free-running or single-shot mode. If one of the two channels is not used, the device still performs both measurements, and the user can simply ignore the results of the unused channel. If the remote diode channel is unused, tie DXP to DXN rather than leaving ...
MAX15040 High-Efficiency, 4A, Step-Down Regulator with General Description
... inductances, making the layout a much simpler task with respect to discrete solutions. Following a simple layout and footprint ensures first-pass success in new designs. The MAX15040 incorporates a high-bandwidth (> 15MHz) voltage-error amplifier. The voltage-mode control architecture and the voltag ...
... inductances, making the layout a much simpler task with respect to discrete solutions. Following a simple layout and footprint ensures first-pass success in new designs. The MAX15040 incorporates a high-bandwidth (> 15MHz) voltage-error amplifier. The voltage-mode control architecture and the voltag ...
MAX1946 Single USB Switch with Autoreset and Fault Blanking in Tiny TDFN
... the switch turns on again and FAULT returns high.The switch cycles on and off if the overload condition persists, resulting in a pulsed output that reduces the average system load. ...
... the switch turns on again and FAULT returns high.The switch cycles on and off if the overload condition persists, resulting in a pulsed output that reduces the average system load. ...
Introduction
... at very high m agnifications d ow n to t he scale of individual ato m s. The STM d oe s t his by m echa nically scan ning a s har p t u ngs te n tip over t he s u rface (sa m ple to be sca n ne d). Piezoelectric ele me nt s can p r ovide t he necessary s m all tra nslations of t he tip. A bias volta ...
... at very high m agnifications d ow n to t he scale of individual ato m s. The STM d oe s t his by m echa nically scan ning a s har p t u ngs te n tip over t he s u rface (sa m ple to be sca n ne d). Piezoelectric ele me nt s can p r ovide t he necessary s m all tra nslations of t he tip. A bias volta ...
TPS4021x 4.5-V to 52-V Input Current Mode Boost Controller (Rev. F)
... Switching frequency setting pin. Connect a resistor from RC pin to VDD of the IC power supply and a capacitor from RC to GND. ...
... Switching frequency setting pin. Connect a resistor from RC pin to VDD of the IC power supply and a capacitor from RC to GND. ...
TM-357A, Dynasty DX
... committee’s judgment, has not demonstrated that exposure to powerfrequency electric and magnetic fields is a human-health hazard.” However, studies are still going forth and evidence continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your expo ...
... committee’s judgment, has not demonstrated that exposure to powerfrequency electric and magnetic fields is a human-health hazard.” However, studies are still going forth and evidence continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your expo ...
FSB50825US Motion SPM 5 Series ®
... 1. BVDSS is the absolute maximum voltage rating between drain and source terminal of each MOSFET inside Motion SPM® 5 product. VPN should be sufficiently less than this value considering the effect of the stray inductance so that VPN should not exceed BVDSS in any case. 2. tON and tOFF include the p ...
... 1. BVDSS is the absolute maximum voltage rating between drain and source terminal of each MOSFET inside Motion SPM® 5 product. VPN should be sufficiently less than this value considering the effect of the stray inductance so that VPN should not exceed BVDSS in any case. 2. tON and tOFF include the p ...
MAX9010–MAX9013 SC70, 5ns, Low-Power, Single-Supply, Precision TTL Comparators General Description
... Note 4: Although Common-Mode Input Voltage Range is restricted to -0.2V ≤ VCM ≤ (VCC - 1.9V), either or both inputs can go to either absolute maximum voltage limit, i.e., from -0.3V to (VCC + 0.3V), without damage. The comparator will make a correct (and fast) logic decision provided that at least o ...
... Note 4: Although Common-Mode Input Voltage Range is restricted to -0.2V ≤ VCM ≤ (VCC - 1.9V), either or both inputs can go to either absolute maximum voltage limit, i.e., from -0.3V to (VCC + 0.3V), without damage. The comparator will make a correct (and fast) logic decision provided that at least o ...
UCC28250 数据资料 dataSheet 下载
... soft-start, used in conjunction with an internal pre-biased startup circuit, allows the controller to gradually reach a steady-state operating point under all output conditions. The UCC28250 can be configured for primary or secondary-side control and either voltage or current mode control can be imp ...
... soft-start, used in conjunction with an internal pre-biased startup circuit, allows the controller to gradually reach a steady-state operating point under all output conditions. The UCC28250 can be configured for primary or secondary-side control and either voltage or current mode control can be imp ...
ONET8511T 数据资料 dataSheet 下载
... If the dc input current exceeds a certain level then it is partially cancelled by means of a controlled current source. This keeps the transimpedance amplifier stage within sufficient operating limits for optimum performance. The automatic gain control circuitry adjusts the voltage gain of the AGC a ...
... If the dc input current exceeds a certain level then it is partially cancelled by means of a controlled current source. This keeps the transimpedance amplifier stage within sufficient operating limits for optimum performance. The automatic gain control circuitry adjusts the voltage gain of the AGC a ...
Damping of Power System Oscillations using Unified Power Flow
... constrained by transient stability, voltage stability and small signal stability. These constraints limit a full utilization of available transmission corridors. Flexible AC Transmission System (FACTS) is the technology that provides the needed corrections of the transmission functionality in order ...
... constrained by transient stability, voltage stability and small signal stability. These constraints limit a full utilization of available transmission corridors. Flexible AC Transmission System (FACTS) is the technology that provides the needed corrections of the transmission functionality in order ...
Temperature Controls For Hot Runner Molding Systems
... CE COMPLIANT! D-M-E Mainframes and Modules Comply with Electromagnetic Compatibility and Low Voltage Directives Control Modules SSM (15 and 30 AMP): The SSM module provides accurate temperature control, including Smart Start® heater dry out circuitry, thermocouple fault displays and auto/manual mode ...
... CE COMPLIANT! D-M-E Mainframes and Modules Comply with Electromagnetic Compatibility and Low Voltage Directives Control Modules SSM (15 and 30 AMP): The SSM module provides accurate temperature control, including Smart Start® heater dry out circuitry, thermocouple fault displays and auto/manual mode ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.