![Electrical Machines lab –II Manual](http://s1.studyres.com/store/data/000094206_1-a64e2f7c69709308143a6b1d6cc1b929-300x300.png)
Polyphase AC Induction Motor TROUBLESHOOTING GUIDE
... If a motor fails to run properly when first installed, ALWAYS check the connection arrangement of the motor leads and the input power lines. The connections must be made in conformance with either the across-the-line start diagrams on the motor nameplate or the reduced voltage start diagrams availab ...
... If a motor fails to run properly when first installed, ALWAYS check the connection arrangement of the motor leads and the input power lines. The connections must be made in conformance with either the across-the-line start diagrams on the motor nameplate or the reduced voltage start diagrams availab ...
A Mechatronic Spotting System that mimics Human Weight
... Fig. 9. Custom-made 2-channel Optical position sensor (45 slots) [15] ...
... Fig. 9. Custom-made 2-channel Optical position sensor (45 slots) [15] ...
Frequently asked questions about FCMA soft starters
... Yes. The FCMA has been used for virtually every starting application. Around 4000 units with cumulative ratings of 1000 MW are working in the field. 5. What is the largest rating FCMA commissioned to date? The largest rating commissioned to date is 14.8 MW, 11KV on a 13 MW synchronous motor. 6. What ...
... Yes. The FCMA has been used for virtually every starting application. Around 4000 units with cumulative ratings of 1000 MW are working in the field. 5. What is the largest rating FCMA commissioned to date? The largest rating commissioned to date is 14.8 MW, 11KV on a 13 MW synchronous motor. 6. What ...
AG-AMIII-01.423-05.4 Electric Motors
... series of high voltage operation and in parallel for low voltage. The starting windings are rated only for low voltage and thus are always connected directly across one set of running windings. ...
... series of high voltage operation and in parallel for low voltage. The starting windings are rated only for low voltage and thus are always connected directly across one set of running windings. ...
CP35508515
... the temperature in the air-conditioned zone at the set reference consistently. Whereas, the existing air conditioners mostly have a single-phase induction motor to drive the compressor in ‗on/off‘ control mode This results in increased losses due to frequent ‗on/off‘ operation with increased mechani ...
... the temperature in the air-conditioned zone at the set reference consistently. Whereas, the existing air conditioners mostly have a single-phase induction motor to drive the compressor in ‗on/off‘ control mode This results in increased losses due to frequent ‗on/off‘ operation with increased mechani ...
experiment 3 title: separately-excited dc generators
... It is important to know dc generators operation because this helps understanding how a separately-excited dc motor can be used as an electric brake in modern dc motor drives. DC motor can be considered as a linear voltage-to-speed converter. Figure 1 illustrates a dc motor operating as a dc generato ...
... It is important to know dc generators operation because this helps understanding how a separately-excited dc motor can be used as an electric brake in modern dc motor drives. DC motor can be considered as a linear voltage-to-speed converter. Figure 1 illustrates a dc motor operating as a dc generato ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
... the salient stator poles. Also the salient rotor poles are made up of steel laminations, without conductors or permanent magnets or cage. Due to this rotor structure, extremely high speed can be obtained as compared to rotors with magnets or windings. Secondly, the motor is cost-effective in compari ...
... the salient stator poles. Also the salient rotor poles are made up of steel laminations, without conductors or permanent magnets or cage. Due to this rotor structure, extremely high speed can be obtained as compared to rotors with magnets or windings. Secondly, the motor is cost-effective in compari ...
H045045059
... is specified as dc with a voltage range from 28 to 42 V as this level enables it to be utilized in both aircraft and automotive electrical systems. For most applications, the requirements are a small size, high efficiency, and simple control structure since high dynamical control of the torque or sp ...
... is specified as dc with a voltage range from 28 to 42 V as this level enables it to be utilized in both aircraft and automotive electrical systems. For most applications, the requirements are a small size, high efficiency, and simple control structure since high dynamical control of the torque or sp ...
Design and Analysis of a New Dual-Stator Permanent
... volume and improve the torque density, double-stator PM machines have been studied recently [1, 2]. With the stator windings carried by inner and outer stators, the space utilization ratio of the machine is largely improved. To reduce the slot number and hence improve the copper fill factor and decr ...
... volume and improve the torque density, double-stator PM machines have been studied recently [1, 2]. With the stator windings carried by inner and outer stators, the space utilization ratio of the machine is largely improved. To reduce the slot number and hence improve the copper fill factor and decr ...
Separately Excited DC Generators
... It is important to know dc generators operation because this helps understanding how a separately-excited dc motor can be used as an electric brake in modern dc motor drives. DC motor can be considered as a linear voltage-to-speed converter. Figure 1 illustrates a dc motor operating as a dc generato ...
... It is important to know dc generators operation because this helps understanding how a separately-excited dc motor can be used as an electric brake in modern dc motor drives. DC motor can be considered as a linear voltage-to-speed converter. Figure 1 illustrates a dc motor operating as a dc generato ...
Volume 7, Issue 2, March-April 2016, pp. 78–90, Article ID:... Available online at
... field oriented vector control technique. However, this conventional DTC approach has some disadvantages such as; high torque ripple and variable switching frequency, which is varying with speed, load torque and the selected hysteresis bands. On the other hand to reduce the torque ripple; the hystere ...
... field oriented vector control technique. However, this conventional DTC approach has some disadvantages such as; high torque ripple and variable switching frequency, which is varying with speed, load torque and the selected hysteresis bands. On the other hand to reduce the torque ripple; the hystere ...
dc machine - UniMAP Portal
... The equivalent compound DC motor (a) Long-shunt connection (b) Shortshunt connection In long shunt compound dc motor, the series field is connected in series with armature and the combination is in parallel with the shunt field. In the short shunt field compound dc motor, the shunt field is in paral ...
... The equivalent compound DC motor (a) Long-shunt connection (b) Shortshunt connection In long shunt compound dc motor, the series field is connected in series with armature and the combination is in parallel with the shunt field. In the short shunt field compound dc motor, the shunt field is in paral ...
Basics For Practical Operation Motor Starting Notes
... lower than the motor’s rated current by a factor of 1√3 = 0.58. Due to the third harmonics currents circulating in the motor windings, a higher setting of the overload relay may be required. This may only be carried out on the basis of utilising a measuring device which records the correct r.m.s. va ...
... lower than the motor’s rated current by a factor of 1√3 = 0.58. Due to the third harmonics currents circulating in the motor windings, a higher setting of the overload relay may be required. This may only be carried out on the basis of utilising a measuring device which records the correct r.m.s. va ...
DSI-700 Instruction Manual
... magnetic clutch. The eddy current clutch is composed of an input drum which is driven by the motor at constant speed, and an output rotor, usually positioned concentrically within the drum. Both members are constructed of magnetically soft iron (low carbon steel), supported by ball and/or roller bea ...
... magnetic clutch. The eddy current clutch is composed of an input drum which is driven by the motor at constant speed, and an output rotor, usually positioned concentrically within the drum. Both members are constructed of magnetically soft iron (low carbon steel), supported by ball and/or roller bea ...
Courseware Sample Electric Power / Controls 25986-F0
... deals with the different techniques associated with the generation and use of electrical energy. The subsystems cover the common machines, and each subsystem is offered with its courseware presented in a student manual. The special applications deal with less common machines, and the courseware is a ...
... deals with the different techniques associated with the generation and use of electrical energy. The subsystems cover the common machines, and each subsystem is offered with its courseware presented in a student manual. The special applications deal with less common machines, and the courseware is a ...
EET-222(6)-ELECTRICAL MC-II
... larger internal voltage EA required for lagging loads than for leading loads • Therefore a larger field current required with lagging loads to get same terminal voltage EA=Kφω • Alternatively for a given IF and load current , Vφ is lower for lagging loads & higher for leading loads • In real synchro ...
... larger internal voltage EA required for lagging loads than for leading loads • Therefore a larger field current required with lagging loads to get same terminal voltage EA=Kφω • Alternatively for a given IF and load current , Vφ is lower for lagging loads & higher for leading loads • In real synchro ...
III Sem
... generators, voltage build up, losses and efficiency, condition for maximum efficiency. DC Motors: Introduction, principals, back-emf, torque of motor, types, characteristics of shunt, series and compound motors, speed control (field and armature control methods), basic idea of solid state devices i ...
... generators, voltage build up, losses and efficiency, condition for maximum efficiency. DC Motors: Introduction, principals, back-emf, torque of motor, types, characteristics of shunt, series and compound motors, speed control (field and armature control methods), basic idea of solid state devices i ...
1 .8 Differentiating EMC ferrite ↔ inductor
... (Figure 1.32). A UP voltage pulse is created at winding NP. Due to the inductance of the winding, this pulse generates a linearly progressive current IP. The following applies: ...
... (Figure 1.32). A UP voltage pulse is created at winding NP. Due to the inductance of the winding, this pulse generates a linearly progressive current IP. The following applies: ...
Variable Frequency Drives
... The starting current is very high, between 3 to 8 times the full load current. Depending on the size of the motor, this can result in voltage sags in the power system. The full torque is applied instantly at starting and the mechanical shock can eventually damage the drive system, particularly with ...
... The starting current is very high, between 3 to 8 times the full load current. Depending on the size of the motor, this can result in voltage sags in the power system. The full torque is applied instantly at starting and the mechanical shock can eventually damage the drive system, particularly with ...
Detecting Broken Rotor Bars With Zero-Setting Protection
... Motor current signature analysis (MCSA) is the most popular method to detect rotor cage faults [4] [5]. This method performs frequency spectrum analysis of the stator currents to determine the electromechanical conditions of the motor and the driven equipment. When one or more bars break, upper and ...
... Motor current signature analysis (MCSA) is the most popular method to detect rotor cage faults [4] [5]. This method performs frequency spectrum analysis of the stator currents to determine the electromechanical conditions of the motor and the driven equipment. When one or more bars break, upper and ...
Electric motor
![](https://commons.wikimedia.org/wiki/Special:FilePath/Motors01CJC.jpg?width=300)
An electric motor is an electrical machine that converts electrical energy into mechanical energy. The reverse of this would be the conversion of mechanical energy into electrical energy and is done by an electric generator.In normal motoring mode, most electric motors operate through the interaction between an electric motor's magnetic field and winding currents to generate force within the motor. In certain applications, such as in the transportation industry with traction motors, electric motors can operate in both motoring and generating or braking modes to also produce electrical energy from mechanical energy.Found in applications as diverse as industrial fans, blowers and pumps, machine tools, household appliances, power tools, and disk drives, electric motors can be powered by direct current (DC) sources, such as from batteries, motor vehicles or rectifiers, or by alternating current (AC) sources, such as from the power grid, inverters or generators. Small motors may be found in electric watches. General-purpose motors with highly standardized dimensions and characteristics provide convenient mechanical power for industrial use. The largest of electric motors are used for ship propulsion, pipeline compression and pumped-storage applications with ratings reaching 100 megawatts. Electric motors may be classified by electric power source type, internal construction, application, type of motion output, and so on.Electric motors are used to produce linear or rotary force (torque), and should be distinguished from devices such as magnetic solenoids and loudspeakers that convert electricity into motion but do not generate usable mechanical powers, which are respectively referred to as actuators and transducers.