• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Choosing the Right Cable
Choosing the Right Cable

... a constant speed regardless of new, changing conditions, scrap would pile up and energy would be wasted. (See Sidebar, “Torque, Speed, Horsepower and Load,” on page 2.) The pulse width modulation (PWM) VFD Drive design is the most common because of its ability to work with motors that range in size ...
SCON-CA/CAL/CGAL/CB/CGB First Step Guide Seventh Edition
SCON-CA/CAL/CGAL/CB/CGB First Step Guide Seventh Edition

... • 3 times of the rated current may flow to the controller during the acceleration/deceleration. Select an interrupter that does not trip with this value of current. If a trip occurs, select an interrupter that possesses the rated current of one grade higher. (Refer to the operation characteristics c ...
Ch 17 Electromagnetic Induction
Ch 17 Electromagnetic Induction

... (i) Direct current is induced in the coil. (ii) The direction of the induced current depends on the direction of rotation of the coil. Reason: The commutator reverses the connections of the coil with the external circuit every half turn of the coil. Thus the current always flows through the external ...
mousey the junkbot
mousey the junkbot

... 10b. Cross a wire from Pin 8 to Pin 11 and another from Pin 6 to Pin 9. These two wires will reverse the motor connections when the relay is engaged. 10c. Plug the capacitor's positive lead into an unused row just left of the relay, and the cathode to the negative power bus. On electrolytic caps, t ...
FPGA-Based Control for Electric Vehicle and Hybrid Electric
FPGA-Based Control for Electric Vehicle and Hybrid Electric

... A trend in the power electronics industry is faster switching, which allows reduction of inductance and capacitance values to achieve equivalent voltage and current ripple. One barrier to switching faster is increased transistor switching losses. Application of IGBTs optimized for lower switching lo ...
Application Notes Ohm’s Law
Application Notes Ohm’s Law

... Conductor: A body so constructed from conducting material that it may be used as a carrier of electric current.* Continuous Duty: A requirement of service that demands operation at a substantially constant load for un indefinitely long time.* Continuous-Duty Resistor: A resistor that is capable of c ...
Methods of Magnetizing Permanent Magnets
Methods of Magnetizing Permanent Magnets

... When magnetic flux penetrates through a part which is tall (at right angles to the direction of flux) but narrow, electrical currents flow in opposite directions on the two sides of the part, as shown in figure 1 . A useful engineering approximation to the true solution is to note that, if the widt ...
CONTENTS: 1. Chassis 2. Transmission 3. Drive
CONTENTS: 1. Chassis 2. Transmission 3. Drive

... occur. This is due to something known as 'ripple current', whereby the voltage from the batteries fluctuates rapidly and drops as the current output increases beyond what it can provide due to high Internal Resistance ( IR ). Lithium batteries have much lower IR levels and so do not overheat or droo ...
Integrating a Current Sense Resistor With a
Integrating a Current Sense Resistor With a

62 Answering AS questions on circuits.p65
62 Answering AS questions on circuits.p65

... an internal resistance. Internal resistance is the name given to the resistance to the flow of charge inside the terminals of the power supply. The power supply is best thought of as a perfect emf in series with this internal resistance inside the confines of the power supply as in the diagram below ...
FURNACE OPERATION OVERVIEW
FURNACE OPERATION OVERVIEW

Lab 17 - College of San Mateo
Lab 17 - College of San Mateo

... binding post. Rotate the VOLTAGE and CURRENT knobs counter-clockwise to their full extent. Plug in and turn on the power supply. Rotate the CURRENT control knob about one half revolution. Hold down the left button of the galvanometer and slowly turn up the power supply voltage, until a deflection of ...
How do you take the first step towards an energy efficient
How do you take the first step towards an energy efficient

... Siemens AG will stamp all standard catalog motors, which are subject to the law, with the efficiency classification / nomenclature IE1 or IE2. Regarding the standard, the motors will be changed over from today‘s EFF nomenclature to the IE nomenclature specified by law in the future (e.g. EFF2 IE1). ...
BASIC Stamp Laboratory, Part 1
BASIC Stamp Laboratory, Part 1

... You are required to use at least one sensor from each of GROUP A and B. In each case, you should use the LED display (to display the outputs). At least one of them must be hooked up to the LED display to run as an analog display, with at least four LED’s being driven to show the level (as was done i ...
S701 Soft Start Controllers and TL Torque Limiters for Intelligent
S701 Soft Start Controllers and TL Torque Limiters for Intelligent

... Limiters provide solid-state reduced voltage control of three-phase and single-phase motors. These easy-to-install, compact devices are rated up to 25A, providing controlled acceleration and deceleration of fractional to 15HP/11kW motors at 480/400V AC. Torque control, soft start, kickstart, and sof ...
Table of Contents - Industrial Manufacturing
Table of Contents - Industrial Manufacturing

... low voltage power distribution, motors, control, drives, and industrial automation. It is beyond the scope of this course to cover all SII products. For more information on SII products, refer to the Siemens Industry, Inc. web site. Before discussing Siemens Industry, Inc. products, it is useful to ...
how the starter motor works
how the starter motor works

... 2. Battery. The battery must be of the correct capacity and be at least 75% charged to provide the necessary current and voltage for correct starter operation. 3. Starter solenoid or relay. The high current required by the starter must be able to be turned on and off. A large switch would be require ...
Rockwell Automation External LTS Template
Rockwell Automation External LTS Template

... offering in its power, performance & feature segment • Simple selection, set-up, & operation • Industry-standard RS-485 communications capabilities • Industry-standard power structure features & installation options ...
Angliiskii
Angliiskii

... l. Isaak Newton was born in 1642 in the family of a poor farmer. The boy began his first scientific experiments at school. 2. While studying at Cambridge University, Newton formulated the binomial theorem. In 1662 Cambridge was closed because of the plague and Newton returned to his native village. ...
Journal of Applied Science and Agriculture
Journal of Applied Science and Agriculture

... power converter in rotor side with less power than stator, which this way of connection provides performance ability even in low voltages within grid. However, one of disadvantages of direct connection of doubly-fed induction generator stators to power grid is sensitivity of these machines to grid d ...
PNIMNiPE_nr64
PNIMNiPE_nr64

... In the algorithm where overmodulation region is considered, two operation modes depending on the reference voltage value are defined. In the mode I the algorithm modifies only the voltage vector amplitude, in the mode II both the amplitude and angle of the voltage vector are influenced [10],[15]. Th ...
1) INTRODUCTION
1) INTRODUCTION

... techniques are used to control the motor from zero and low speed up to full speed operation. The selfsensing technique is used at zero and low speeds to start the machine, then the control is switched to a back-EMF based sensor less technique for the normal higher speed operating range of the machin ...
Unit C 7-5
Unit C 7-5

... are three separate and distinct singlephase currents, which are combined so they can be transmitted over three or four wires. This greatly increases machine operating power. ...
AT 121 - Chapter 2 - Basic Electrical Principals
AT 121 - Chapter 2 - Basic Electrical Principals

Basic Concepts - New Age International
Basic Concepts - New Age International

... It is seen from Blv and BlI equations that generator and motor actions are based on the physical reactions on conductors situated in magnetic fields. When a relative motion between conductor and field exists, an emf is generated in the conductor and when a conductor carries current and is situated i ...
< 1 ... 39 40 41 42 43 44 45 46 47 ... 213 >

Brushed DC electric motor



A brushed DC motor is an internally commutated electric motor designed to be run from a direct current power source. Brushed motors were the first commercially important application of electric power to driving mechanical energy,and DC distribution systems were used for more than 100 years to operate motors in commercial and industrial buildings. Brushed DC motors can be varied in speed by changing the operating voltage or the strength of the magnetic field. Depending on the connections of the field to the power supply, the speed and torque characteristics of a brushed motor can be altered to provide steady speed or speed inversely proportional to the mechanical load. Brushed motors continue to be used for electrical propulsion, cranes, paper machines and steel rolling mills. Since the brushes wear down and require replacement, brushless DC motors using power electronic devices have displaced brushed motors from many applications